文献速递泌尿生殖腹部MR

三维卷积神经网络用于前列腺MRI分割及人工神经网络与椭球公式前列腺体积测量的比较

Three-Dimensional Convolutional Neural Network for Prostate MRI Segmentation and Comparison of Prostate Volume Measurements by Use of Artificial Neural Network and Ellipsoid Formula.
PubMed 文献 · AJR Am J Roentgenol · 2020-03-24

本研究纳入330套MRI图像集(260套训练、70套测试)评估三维卷积神经网络自动分割前列腺的性能,并与椭球公式比较体积估计。全前列腺Dice相似系数87.12%,移行区76.48%。测试集中自动网络体积与VGT和VSW均值无显著差异(p=0.689),而椭球公式体积与该均值差异显著(p<0.001)。

要点

  • 全前列腺Dice相似系数87.12%,移行区76.48%。
  • 测试集中网络体积与VGT和VSW均值无显著差异(p=0.689)。
  • 椭球公式体积与VGT和VSW均值差异显著(p<0.001)。

核心结论

  • 全自动网络所研究的分割方法提供可靠的全前列腺体积估计,与椭球公式所得结果相比具有优势。

研究设计与样本

  • 研究纳入330套MR图像集,分为260套训练集和70套测试集用于全前列腺自动分割,其中162套训练集和50套测试集用于移行区分割,由两位放射科医生手工分割辅助。

关键影像表现/征象

  • 全前列腺Dice相似系数为87.12%,移行区为76.48%。

诊断标准与关键数值

  • 测试集全前列腺中网络体积与VGT和VSW均值无显著差异(p=0.689)。
  • 测试集全前列腺中椭球公式体积与VGT和VSW均值差异显著(p<0.001)。
  • 移行区测试集中各体积估计间无显著差异。
  • 各体积估计间总体组内相关系数优秀(0.887-0.995)。
  • 全前列腺测试集中VGT与网络体积平均误差(2.5)小于VGT与椭球公式体积平均误差(3.3)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purposes of this study were to assess the performance of a 3D convolutional neural network (CNN) for automatic segmentation of prostates on MR images and to compare the volume estimates from the 3D CNN with those of the ellipsoid formula. MATERIALS AND METHODS. The study included 330 MR image sets that were divided into 260 training sets and 70 test sets for automated segmentation of the entire prostate. Among these, 162 training sets and 50 test sets were used for transition zone segmentation. Assisted by manual segmentation by two radiologists, the following values were obtained: estimates of ground-truth volume (VGT), software-derived volume (VSW), mean of VGT and VSW (VAV), and automatically generated volume from the 3D CNN (VNET). These values were compared with the volume calculated with the ellipsoid formula (VEL). RESULTS. The Dice similarity coefficient for the entire prostate was 87.12% and for the transition zone was 76.48%. There was no significant difference between VNET and VAV (p = 0.689) in the test sets of the entire prostate, whereas a significant difference was found between VEL and VAV (p < 0.001). No significant difference was found among the volume estimates in the test sets of the transition zone. Overall intraclass correlation coefficients between the volume estimates were excellent (0.887-0.995). In the test sets of entire prostate, the mean error between VGT and VNET (2.5) was smaller than that between VGT and VEL (3.3). CONCLUSION. The fully automated network studied provides reliable volume estimates of the entire prostate compared with those obtained with the ellipsoid formula. Fast and accurate volume measurement by use of the 3D CNN may help clinicians evaluate prostate disease.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Lee DK, Sung DJ, Kim CS, et al. Three-Dimensional Convolutional Neural Network for Prostate MRI Segmentation and Comparison of Prostate Volume Measurements by Use of Artificial Neural Network and Ellipsoid Formula. AJR Am J Roentgenol. 2020. PMID: 32208009. doi:10.2214/AJR.19.22254

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。