文献速递泌尿生殖腹部MR

3T MRI 前列腺检查使用与不使用直肠内线圈:与全标本病理切片 Gleason 评分对照

MRI of the Prostate With and Without Endorectal Coil at 3 T: Correlation With Whole-Mount Histopathologic Gleason Score.
PubMed 文献 · AJR Am J Roentgenol · 2020-03-11

研究纳入23例经活检证实前列腺癌患者,同次就诊分别使用与不使用直肠内线圈(ERC)行3T MRI,均行根治性前列腺切除术并以全标本病理为参考标准。两种方式对 Gleason 评分4+3及以上肿瘤诊断准确性相当,但使用ERC对 Gleason 评分3+4肿瘤检出更优;ADC值与Gleason评分显著相关,使用与不使用ERC所测病灶ADC值无显著差异。

要点

  • 3T MRI使用与不使用直肠内线圈(ERC)图像质量相当(3.8 vs 3.5)。
  • 使用ERC对 Gleason 评分3+4肿瘤检出优于不使用ERC。
  • 使用与不使用ERC所测病灶ADC值无显著差异。

关键影像表现/征象

  • 全标本病理检出29个直径大于0.5 cm的癌灶,其中18个肿瘤 Gleason 评分7或以上。
  • 使用ERC时13个 Gleason 评分3+4肿瘤全部检出,不使用ERC时仅检出9个。
  • 5个 Gleason 评分低于3+4的肿瘤中,使用与不使用ERC均漏诊1个。

诊断标准与关键数值

  • 使用ERC时,两位放射科医生对 Gleason 评分7或以上肿瘤的AUC分别为0.96和0.96;不使用ERC时分别为0.88和0.91。
  • 图像质量采用5分制评估,使用ERC为3.8,不使用ERC为3.5。
  • 病灶评估采用PI-RADSv2。

临床应用与阅片要点

  • 使用与不使用ERC的图像质量相当(3.8 vs 3.5),ADC值与Gleason评分显著相关,且使用与不使用ERC所测病灶ADC值无显著差异。
  • 使用ERC对 Gleason 评分3+4肿瘤的检出优于不使用ERC(13个全部检出 vs 检出9个)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this article is to prospectively compare image quality and diagnostic accuracy of clinically significant prostate cancer with and without endorectal coil (ERC) at 3 T using a combination of T2-weighted and diffusion-weighted MRI. SUBJECTS AND METHODS. Twenty-three patients with biopsy-proven prostate cancer underwent MRI with and without ERC at the same visit. Patients subsequently underwent radical prostatectomy. Specimens were assessed by whole-mount histopathologic examination. Two radiologists reviewed MR images for image quality (5-point scale) and disease using Prostate Imaging Reporting and Data Systems version 2 (PI-RADSv2). Sensitivity, specificity, and area under the ROC curve (AUC) were calculated with and without ERC. Additionally, apparent diffusion coefficient (ADC) was correlated with Gleason score and ADC values of each lesion were compared with and without ERC. RESULTS. Image quality was comparable with and without ERC (3.8 vs 3.5). Twenty-nine cancer foci larger than 0.5 cm in diameter were found in 23 patients on histopathologic examination; 18 tumors had a Gleason score of 7 or greater. Two radiologists recorded AUC for tumors with a Gleason score of 7 or greater as 0.96 and 0.96 with ERC and 0.88 and 0.91 without ERC. All 13 tumors with a Gleason score of 3 + 4 were detected with ERC, but only 9 were detected without ERC. One of five tumors with Gleason scores less than 3 + 4 was missed with and without ERC. ADC significantly correlated with Gleason score. There was no significant difference in the ADC of a lesion on MRI with and without an ERC. CONCLUSION. MRI with and without ERC was equally accurate at showing prostate cancers with Gleason scores of 4 + 3 or greater. However, MRI with ERC was superior at showing cancer with a Gleason score of 3 + 4. There was no significant difference in ADC values between scores acquired with or without an ERC.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Dhatt R, Choy S, Co SJ, et al. MRI of the Prostate With and Without Endorectal Coil at 3 T: Correlation With Whole-Mount Histopathologic Gleason Score. AJR Am J Roentgenol. 2020. PMID: 32160050. doi:10.2214/AJR.19.22094

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。