文献速递泌尿生殖腹部MR

Fleet's™灌肠剂肠道准备对前列腺MRI质量的影响

Impact of bowel preparation with Fleet's™ enema on prostate MRI quality.
PubMed 文献 · Abdom Radiol (NY) · 2020-01-01

研究纳入117例前瞻性收集的主动监测患者,均在前列腺MRI前接受或不接受Fleet's™灌肠剂肠道准备,两次扫描间隔12个月内。结果显示灌肠后直肠前后径显著更小,但DWI变形和整体图像质量的改善有限,且读者间一致性仅中等至弱。作者认为肠道准备的价值在本研究中未获确证。

要点

  • 灌肠后直肠前后径显著小于未灌肠扫描(p=0.002)。
  • 仅读者2报告灌肠后DWI变形显著改善(p=0.02),读者1无显著差异(p=0.17)。
  • 直肠扩张、DWI变形和伪影的读者间一致性分别为中等、弱和弱。

核心结论

  • 前列腺MRI前使用灌肠剂行肠道准备可能减少直肠气体,但对DWI变形和整体图像质量的影响有限。
  • 本研究未确证肠道准备的价值。

研究设计与样本

  • 前瞻性收集的117例主动监测患者,每例均接受不灌肠(prep-)和灌肠(prep+)两次前列腺MRI,间隔12个月内。
  • 由两名独立读者评估直肠前后径、直肠扩张程度和图像质量评分;DWI变形通过不同b值图像与T2WI的解剖不匹配程度定量评估。

关键影像表现/征象

  • 灌肠后(prep+)直肠前后径均值显著小于未灌肠(prep-)(p=0.002)。
  • 读者2评估的直肠扩张评分在灌肠后显著更低(p<0.001),读者1无显著差异(p=0.09)。
  • 读者2评估的DWI变形在灌肠后显著改善(p=0.02)。
  • 读者1评估的DWI变形(p=0.17)和伪影(p=0.49)在灌肠前后无显著差异。
  • 读者2评估的DWI伪影在灌肠前后无显著差异(p=0.55)。

诊断标准与关键数值

  • DWI变形定量评估采用不同b值图像与T2WI之间的解剖不匹配程度。
  • DWI伪影定性评分基于模糊、信噪比差和伪影线的存在。
  • 直肠扩张、DWI变形和伪影的读者间一致性Kappa评分分别为中等、弱和弱。

临床应用与阅片要点

  • 灌肠后直肠前后径缩小,但DWI变形和伪影的改善在不同读者间不一致。
  • 阅片时需注意直肠扩张和DWI变形的读者间一致性仅为中等至弱。

局限性

  • 灌肠对DWI变形和整体图像质量的影响有限(modest effects),本研究未确证肠道准备的价值。
  • 直肠扩张、DWI变形和伪影的读者间一致性分别为中等、弱和弱,存在读者间变异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To investigate the effects of cleansing Fleet's™ enema (FE) on rectal distention and image quality of diffusion-weighted imaging (DWI) in prostate magnetic resonance imaging (MRI).

METHODS: This study included 117 prospectively accrued active surveillance patients who underwent prostate MRI both without (prep-) and with bowel preparation consisting of FE (prep+) obtained within 12 months of each other. The anterior-posterior (AP) diameter of the rectum, degree of perceived distention in the rectum and image quality scores were assessed by two independent readers for both (prep- and prep+) scans. DWI distortion was assessed quantitatively using the degree of anatomic mismatches between images obtained at different b values and the T2-weighted MRI. DWI artifact was qualitatively scored based on the presence of blurring, poor signal-to-noise, and artifact lines. The difference in rectal AP diameters between the two methods was tested by the paired Wilcoxon rank test. Stuart Maxell test was used in comparing rectal distention, DWI distortion, and artifact. Reader agreement was estimated by kappa statistics. p values < 0.05 were considered statistically significant.

RESULTS: Mean rectal AP diameter was significantly larger in prep- compared with prep+ scans (p = 0.002). Subjective scores demonstrated inter-reader variability. For instance, the rectal distention score was significantly lower in prep+ for reader 2 (p < 0.001) whereas it was not significant for reader 1 (p = 0.09). Reader 2 also found significant improvement in DWI distortion (p = 0.02) in prep+ scans. There was no significant difference between prep- and prep+ in DWI distortion and artifacts for reader 1 (p = 0.17 and p = 0.49, respectively), or DWI artifacts for reader 2 (p = 0.55). Kappa scores were moderate for rectal distension, but weak for DWI distortion, and artifacts.

CONCLUSION: Bowel preparation with enema prior to prostate MRI may diminish rectal gas but has modest effects on DWI distortion and overall image quality. The value of bowel prep is not conclusively validated in this study.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Coskun M, Mehralivand S, Shih JH, et al. Impact of bowel preparation with Fleet's™ enema on prostate MRI quality. Abdom Radiol (NY). 2020. PMID: 32211948. doi:10.1007/s00261-020-02487-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。