文献速递腹部CT

胰岛素瘤检测:一站式胰腺灌注CT结合计算平均时间图像可替代双期加灌注扫描的组合

Detection of insulinoma: one-stop pancreatic perfusion CT with calculated mean temporal images can replace the combination of bi-phasic plus perfusion scan.
PubMed 文献 · Eur Radiol · 2020-03-18

本研究回顾性纳入45例疑似胰岛素瘤患者,评估一站式胰腺灌注CT生成的平均时间图像替代双期扫描加灌注扫描的可行性。结果显示平均时间图像质量不劣于或优于双期CT,诊断敏感度和阴性预测值更高,且省略双期扫描使辐射剂量降低25%±4%。

要点

  • 平均时间图像由灌注CT动态数据平均生成,可模拟动脉期和门静脉期图像。
  • 平均时间图像诊断胰岛素瘤的敏感度和阴性预测值均优于传统双期CT。
  • 仅用灌注CT的平均时间图像可省略双期扫描,辐射剂量降低25%±4%。

关键影像表现/征象

  • 与双期CT图像相比,MTA和MTPV数据集的图像噪声、SNR和CNR均不劣于或优于双期CT(门静脉的噪声和CNR,p=0.565和p=0.227)。
  • MTA和MTPV图像的主观图像质量更优(p<0.001至p=0.004)。

诊断标准与关键数值

  • 读者1:平均时间图像的敏感度为95%,双期CT为75%;平均时间图像的NPV为75%,双期CT为37.5%。
  • 读者2:平均时间图像的敏感度为97.5%,双期CT为72.5%;平均时间图像的NPV为85.7%,双期CT为35.3%。

临床应用与阅片要点

  • 平均时间图像可重现常规双期图像(动脉期和门静脉期),图像质量不劣于或优于原生双期CT。
  • 平均时间图像对胰岛素瘤的诊断敏感度和NPV优于传统双期CT。
  • 平均时间成像可使胰腺灌注CT单独用于检测胰岛素瘤,无需额外双期CT,并节省辐射剂量。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the feasibility of one-stop pancreatic perfusion CT with mean temporal (MT) imaging replacing the combination of a bi-phasic scan plus a perfusion scan to detect insulinoma.

MATERIAL AND METHODS: Forty-five patients with suspected insulinoma, who underwent both biphasic and perfusion CT, were enrolled in this retrospective study. MT datasets including images for different delineation purposes were generated by averaging 3 dynamic datasets from perfusion CT, which are MTA for arterial, MTPV for portal vein and MTO for lesions. Two readers assessed the image quality and diagnostic performance separately for biphasic and MT datasets. Radiation doses were also assessed. Paired t tests, Wilcoxon signed-rank tests and McNemar's tests were applied for comparison.

RESULTS: Compared with bi-phasic CT images, image noise, SNR and CNR of the MTA and MTPV datasets were all non-inferior (noise and CNR of the portal vein, p = 0.565 and p = 0.227, respectively) or superior (p ≤ 0.001). The subjective image quality was better in the MTA and MTPV images (p < 0.001 to p = 0.004). The sensitivity and NPV of MT images were also better (95% vs 75% and 75% vs 37.5% for reader 1; 97.5% vs 72.5% and 85.7% vs 35.3% for reader 2). Omitting the bi-phasic scan resulted in a dose reduction of 25% ± 4%.

CONCLUSION: MT imaging can allow pancreatic perfusion CT to be used alone without the need for an additional bi-phasic CT in the detection of insulinoma.

KEY POINTS: • Mean temporal images reconstructed from perfusion CT with an averaging technique reproduce usual bi-phasic images (arterial and portal phases). • The image quality of mean temporal images is non-inferior or superior to native bi-phasic CT. The sensitivity and NPV for the diagnosis of insulinoma are better for mean temporal images than for traditional bi-phasic CT. • Mean temporal imaging can allow pancreatic perfusion CT to be used alone without the need for an additional bi-phasic CT in the detection of insulinoma. Radiation dose saving is important.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Li J, Chen XY, Xu K, et al. Detection of insulinoma: one-stop pancreatic perfusion CT with calculated mean temporal images can replace the combination of bi-phasic plus perfusion scan. Eur Radiol. 2020. PMID: 32189051. doi:10.1007/s00330-020-06657-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。