基于增强CT影像组学与临床数据鉴别胆囊息肉样病变良恶性的价值
回顾性纳入145例病理证实的≥1 cm胆囊息肉样病变患者,于胆囊切除术前3周行腹部增强CT,按7:3随机分为训练集与测试集,提取门静脉期影像组学特征并结合临床特征构建模型。测试集中影像组学模型AUC为0.924、临床模型AUC为0.861、联合模型AUC为0.931,三者AUC差异无统计学意义。结论认为基于CT的影像组学有助于鉴别≥1 cm的胆囊息肉良恶性。
要点
- 门静脉期CT影像组学模型鉴别≥1 cm胆囊息肉良恶性,测试集AUC为0.924。
- 联合临床特征后AUC为0.931,但与单一模型AUC差异无统计学意义。
- 影像组学模型测试集准确率88.6%、特异度88.0%、敏感度89.5%。
核心结论
- 基于CT图像的影像组学可能有助于鉴别≥1 cm的胆囊息肉样病变的良恶性。
研究设计与样本
- 回顾性研究纳入145例病理证实的胆囊息肉样病变(≥1 cm)患者,均于胆囊切除术前3周内行腹部增强CT,检查时间为2013年1月至2019年1月。
- 按70%随机选入训练集、30%独立用于测试集,提取门静脉期CT影像组学特征并结合临床特征,采用LASSO回归降维、多变量logistic回归构建影像组学、临床及联合模型。
- 以病理结果为参考标准,用ROC曲线和决策曲线评估三种模型的鉴别性能。
关键影像表现/征象
- 影像组学特征提取自胆囊息肉样病变的门静脉期CT图像。
诊断标准与关键数值
- 测试集中影像组学模型AUC为0.924,临床模型AUC为0.861。
- 影像组学模型测试集准确率88.6%、特异度88.0%、敏感度89.5%。
- 联合模型AUC为0.931、特异度84.0%、敏感度89.5%。
- 两个单一模型与联合模型的AUC差异无统计学意义。
临床应用与阅片要点
- 作者认为基于CT的影像组学可能有助于术前鉴别≥1 cm的胆囊息肉样病变良恶性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To develop and validate a novel method based on radiomics for the preoperative differentiation of benign and malignant gallbladder polypoid lesions (PLG).
PATIENTS AND METHODS: A total of 145 patients with pathological proven gallbladder polypoid lesions ≥ 1 cm were included in this retrospective study. All the patients underwent abdominal contrast-enhanced computed tomography (CT) examinations 3 weeks before cholecystectomy from January 2013 to January 2019. Seventy percent of the cases were randomly selected for the training dataset, and 30% of the cases were independently used for testing. Radiomics features extracted from portal venous-phase CT of the PLG and clinical features were analyzed, and the LASSO regression algorithm was used for data dimension reduction. Multivariable logistic regression was used to generate radiomics signatures, clinical signatures, and combination signatures. The receiver operating characteristic (ROC) curve and decision curve were plotted to assess the differentiating performance of the three signatures.
RESULTS: The area under the ROC curve (AUC) of the radiomics signature and clinical signature was 0.924 and 0.861 in the testing dataset, respectively. For the radiomics signature, the accuracy was 88.6%, with 88.0% specificity and 89.5% sensitivity. When combined, the AUC was 0.931, the specificity was 84.0%, and the sensitivity was 89.5%. The differences between the AUC values of the two sole models and the combination model were statistically nonsignificant.
CONCLUSION: Radiomics based on CT images can be helpful to differentiate benign and malignant gallbladder polyps ≥ 1 cm in size.
引用
- Yang X, Liu Y, Guo Y, et al. Utility of radiomics based on contrast-enhanced CT and clinical data in the differentiation of benign and malignant gallbladder polypoid lesions. Abdom Radiol (NY). 2020. PMID: 32166337. doi:10.1007/s00261-020-02461-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。