术前应用二维剪切波弹性成像检测肝细胞癌患者肝纤维化:测量位置的选择
该前瞻性研究纳入106例肝细胞癌手术患者,于2017年3月至2018年5月用二维剪切波弹性成像测量距肿瘤边界0-1、1-2、2-5 cm处的肝硬度。距肿瘤2-5 cm处测量的技术成功率显著高于瘤周组织,且诊断肝硬化(F4)和严重炎症(A3)的曲线下面积更高,提示测量应选择距肿瘤边缘2-5 cm处。
要点
- 肝细胞癌患者术前评估肝纤维化时,二维剪切波弹性成像测量位置应距肿瘤边缘2-5 cm。
- 距肿瘤2-5 cm处测量的技术成功率显著高于距肿瘤0-1 cm和1-2 cm的瘤周组织(p < 0.001)。
- 距肿瘤2-5 cm处诊断肝硬化(F4)和严重炎症(A3)的ROC曲线下面积高于瘤周组织。
核心结论
- 二维剪切波弹性成像有助于肝细胞癌患者肝切除术前评估肝纤维化。
- 为获得更高的成功率和更好的诊断准确性,肝硬度测量应距肿瘤边缘2-5 cm进行。
研究设计与样本
- 前瞻性研究,纳入106例随后接受手术的肝细胞癌患者,研究时间为2017年3月至2018年5月。
- 使用二维剪切波弹性成像测量肝硬度,按距肿瘤边界0-1 cm、1-2 cm和2-5 cm分为1组、2组和3组。
- 采用Spearman相关分析评估肝硬度与肝纤维化及炎症的关系,采用ROC曲线分析评估诊断准确性。
诊断标准与关键数值
- 距肿瘤2-5 cm处(3组)诊断肝硬化(F4)和严重炎症(A3)的ROC曲线下面积高于距肿瘤0-1 cm和1-2 cm处(1组和2组)。
- 距肿瘤2-5 cm处(3组)的技术成功率显著高于瘤周组织(1组和2组)(p < 0.001)。
临床应用与阅片要点
- 对肝细胞癌患者术前用二维剪切波弹性成像评估肝纤维化时,测量位置选择距肿瘤边缘2-5 cm处可获得更高的技术成功率和诊断准确性。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The aim of this study was to pre-operatively investigate the diagnostic performance of 2D shear wave elastography (2D-SWE) for staging liver fibrosis and inflammation in patients with hepatocellular carcinoma (HCC) who then undergo surgery and to determine the optimal locations for measurement. In total, 106 patients were enrolled in this prospective study from March 2017 to May 2018. Two-dimensional SWE was used to measure liver stiffness (LS) in each patient 0-1, 1-2 and 2-5 cm from the tumor border (groups 1, 2 and 3, respectively). Spearman's correlation was used to evaluate the relationships between LS and hepatic fibrosis and between LS and inflammation. Receiver operating characteristic curve (ROC) analysis was used to evaluate the diagnostic accuracy of 2D-SWE. The technical success rate of SWE in tissue distant from the tumor (group 3) was significantly higher than that in peri-tumoral tissue (groups 1 and 2) (p < 0.001). Moreover, the area under the ROC for diagnosing cirrhosis (F4) and severe inflammation (A3) was higher for group 3 than for groups 1 and 2. Our results suggest that 2D-SWE is a helpful approach to assessment of hepatic fibrosis in HCC patients before hepatic resection. We found that to achieve a superior success rate and preferable diagnosis accuracy for patients with HCC, LS measurement should be performed 2-5 cm from the tumor margin.
引用
- Xie LT, Gu JH, Chai WL, et al. Pre-operative Detection of Liver Fibrosis in Hepatocellular Carcinoma Patients Using 2D Shear Wave Elastography: Where to Measure? Ultrasound Med Biol. 2020. PMID: 32217029. doi:10.1016/j.ultrasmedbio.2020.02.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。