文献速递腹部技术与安全US

口服纤维素基造影剂增强经腹超声在显示贲门及胃底静脉曲张中的应用价值

Utility of Transabdominal Ultrasonography Enhanced by Oral Cellulose-Based Contrast Agent in Depicting Varices at Cardia and Fundus.
PubMed 文献 · Ultrasound Med Biol · 2020-03-23

前瞻性纳入239例肝硬化患者,比较经腹超声+空腹、+饮水、+口服纤维素基造影剂三种方案对贲门及胃底静脉曲张的显示率,并以胃镜为金标准。口服造影剂组显示率89.6%,高于饮水组59.2%和空腹组10.5%;超声分级与胃镜分级总体符合率93%。

要点

  • 口服纤维素基造影剂后经腹彩色多普勒超声可显著提高贲门及胃底静脉曲张显示率。
  • 超声分级基于静脉直径和血流速度,U1-U5分级与胃镜分级总体符合率93%。
  • 该法为无创动态随访肝硬化静脉曲张提供新途径。

核心结论

  • 口服纤维素基造影剂经腹超声(TUS-OCCA)大幅提高贲门及胃底静脉曲张检出率,可实现诊断与定量分级,为无创动态随访提供优良方法。

研究设计与样本

  • 前瞻性研究,2016年8月至2019年8月纳入239例肝硬化患者,其中出血组71例、非出血组168例。
  • 按超声方案分为空腹组(TUS-ES)、饮水组(TUS-OW)和口服纤维素基造影剂组(TUS-OCCA),以胃镜为金标准。
  • 采用经腹彩色多普勒超声,基于静脉直径和血流速度进行Ux-U5分级。

关键影像表现/征象

  • TUS-ES组直接观察到静脉曲张者10.5%(25/239),TUS-OW组59.2%(58/98),TUS-OCCA组89.6%(104/116),三组检出率差异显著(TUS-OCCA > TUS-OW > TUS-ES,p < 0.05)。
  • Ux 34例,U0 18例,U1 50例,U2 41例,U3 16例,U4 46例,U5 34例。

诊断标准与关键数值

  • Ux:难以分辨胃底和贲门或勾画静脉曲张;U0:未检出静脉曲张。
  • U1:直径<5 mm,流速<10 cm/s;U2:直径<5 mm,流速≥10 cm/s。
  • U3:直径5-10 mm,流速<10 cm/s;U4:直径5-10 mm,流速≥10 cm/s。
  • U5:直径>10 mm,任意流速。
  • 按静脉曲张直径分级,TUS与胃镜总体符合率为93%(174/187)。

临床应用与阅片要点

  • 口服纤维素基造影剂后经腹彩色多普勒超声可作为无创手段用于贲门及胃底静脉曲张的检出和定量分级。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The use of transabdominal color Doppler ultrasound after oral administration of an oral cellulose-based contrast agent (TUS-OCCA) in depicting varices at the cardia and fundus was explored. Both gastroscopy and transabdominal color Doppler ultrasound (TUS) were performed for this purpose, with gastroscopy serving as the gold standard. Patients were assigned by TUS protocol to one of three groups: TUS + empty stomach (TUS-ES); TUS + oral water intake (TUS-OW); and TUS-OCCA. TUS-based grading of varices reflected venous diameters and blood flow velocities, designated as follows: Ux = difficulty discerning gastric fundus and cardia or delineating varices; U0 = no detectable varices; U1 = diameter <5 mm, flow rate <10 cm/s; U2 = diameter <5 mm, flow rate ≥10 cm/s; U3 = diameter 5-10 mm, flow rate <10 cm/s; U4 = diameter 5-10 mm, flow rate ≥10 cm/s; and U5 = diameter >10 mm, any flow rate. Between August 2016 and August 2019, 239 patients with cirrhosis were enrolled prospectively, including bleeding (n = 71) and non-bleeding (n = 168) groups. Varices were directly observed in 10.5% (25/239) of TUS-ES group members, compared with 59.2% (58/98) of the TUS-OW group and 89.6% (104/116) of the TUS-OCCA group; all detection rates differed significantly (TUS-OCCA > TUS-OW > TUS-ES, p < 0.05). TUS-based grading (as defined) revealed the following patient distribution: Ux, n = 34; U0, n = 18; U1, n = 50; U2, n = 41; U3, n = 16; U4, n = 46; U5, n = 34. In grading by variceal diameter, overall correspondence between TUS and gastroscopy was 93% (174/187). TUS-OCCA greatly improved rates of detection of varices at the cardia and fundus, offering a new method by which diagnosis and quantitative grading may be achieved and affording an excellent, non-invasive approach to dynamic follow-up.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Liu Z, Dou X, Guo J, et al. Utility of Transabdominal Ultrasonography Enhanced by Oral Cellulose-Based Contrast Agent in Depicting Varices at Cardia and Fundus. Ultrasound Med Biol. 2020. PMID: 32217027. doi:10.1016/j.ultrasmedbio.2020.02.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。