对比增强超声与对比增强磁共振成像采用肝脏影像报告和数据系统诊断局灶性肝脏病变的比较
本回顾性研究纳入63例患者共84个局灶性肝脏病变,由两名放射科医师独立评估对比增强超声与对比增强磁共振成像的LI-RADS分类。对比增强超声LR-5/LR-TIV诊断肝细胞癌的敏感度高于对比增强磁共振成像,两者主要特征出现频率不同但观察者间一致性均优良。
要点
- 对比增强超声LR-5/LR-TIV诊断肝细胞癌敏感度高于对比增强磁共振成像。
- 对比增强超声上LR-5类别出现频率高于对比增强磁共振成像。
- 对比增强超声动脉期高增强较少见而廓清表现更常见。
关键影像表现/征象
- 对比增强超声上动脉期高增强出现频率低于对比增强磁共振成像(46.4% vs. 61.9%,p = 0.044)。
- 对比增强超声上廓清表现出现频率高于对比增强磁共振成像(50.0% vs. 28.6%,p = 0.004)。
- 两名阅片者对动脉期高增强和廓清表现的观察者间一致性在对比增强超声和对比增强磁共振成像上均优良。
诊断标准与关键数值
- 对比增强超声LR-5/LR-TIV诊断肝细胞癌敏感度为88.9%(40/45,95%CI:76.5%-95.2%),对比增强磁共振成像为64.4%(29/45,95%CI:49.8%-76.8%),p = 0.006。
- 对比增强超声LR-5/LR-TIV诊断肝细胞癌敏感度为82.2%(37/45,95%CI:68.7%-90.7%),对比增强磁共振成像为62.2%(28/45,95%CI:47.6%-74.9%),p = 0.034。
- 对比增强超声上LR-5出现频率高于对比增强磁共振成像(44.0% vs. 25.0%,p = 0.009;42.9% vs. 26.2%,p = 0.023)。
- 对比增强超声和对比增强磁共振成像上判定LR-5的观察者间一致性均为中等。
临床应用与阅片要点
- 采用LI-RADS评估局灶性肝脏病变时,对比增强超声对肝细胞癌的诊断敏感度高于对比增强磁共振成像。
- 对比增强超声与对比增强磁共振成像的主要特征出现频率存在差异,判读时需结合检查方法分别评估。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The aim of this retrospective study was to evaluate the Liver Imaging Reporting and Data System (LI-RADS) categorization of focal liver lesions (FLLs) on contrast-enhanced ultrasound (CEUS) in comparison with contrast-enhanced magnetic resonance imaging (CE-MRI). A total of 63 patients with 84 FLLs were included in the final study population, after review of the electronic medical records and clinical data. Two trained radiologists evaluated all CEUS and CE-MRI images independently. They assigned a LI-RADS category to each FLL and assessed major features based on CEUS LI-RADS Version 2017 and computed tomography/MRI LI-RADS Version 2018. The generalized estimating equation method was used to compare the diagnostic performance of the LI-RADS algorithm between CEUS and CE-MRI. The sensitivity of LR-5/LR-TIV (tumor in vein) categories for diagnosing hepatocellular carcinoma (HCC) differed significantly between CEUS and CE-MRI (88.9% [40/45], 95% confidence interval [CI]: 76.5%-95.2%), versus 64.4% (29/45; 95% CI: 49.8%-76.8%), p = 0.006; 82.2% (37/45; 95% CI: 68.7%-90.7%), versus 62.2% (28/45; 95% CI: 47.6%-74.9%), p = 0.034. Inter-observer agreement was substantial for assigning LR-5 on both CEUS and CE-MRI. For both reviewers, there was a higher frequency of LR-5 (44.0% vs. 25.0%, p = 0.009; 42.9% vs. 26.2%, p = 0.023) in CEUS compared with CE-MRI. Arterial phase hyper-enhancement (APHE) was less frequently observed on CEUS than on CE-MRI (46.4% vs. 61.9%, p = 0.044). However, the washout appearance was observed more frequently on CEUS than on CE-MRI (50.0% vs. 28.6%, p = 0.004). Inter-observer agreement between the two reviewers on APHE and washout appearance was excellent for both CEUS and CE-MRI. These findings suggest that CEUS had a much higher sensitivity than CE-MRI in the diagnosis of HCC using LI-RADS, and although the frequencies of major features differed, inter-observer agreement between the two reviewers on major features of HCC was excellent for both CEUS and CE-MRI.
引用
- Wang JY, Feng SY, Yi AJ, et al. Comparison of Contrast-Enhanced Ultrasound versus Contrast-Enhanced Magnetic Resonance Imaging for the Diagnosis of Focal Liver Lesions Using the Liver Imaging Reporting and Data System. Ultrasound Med Biol. 2020. PMID: 32115307. doi:10.1016/j.ultrasmedbio.2020.01.023