文献速递腹部技术与安全CT

与CT检查较低辐射剂量相关的组织因素和质量改进策略

Organizational Factors and Quality Improvement Strategies Associated With Lower Radiation Dose From CT Examinations.
PubMed 文献 · J Am Coll Radiol · 2020-03-17

该横断面调查研究覆盖美国、欧洲和日本19个医疗组织、100个影像中心,同步测量腹部CT辐射剂量并调查放射科领导者。90个影像中心完成问卷(90%),收集182,415例腹部CT扫描。单因素分析发现8项策略与较低平均剂量或高频高剂量检查减少相关,高剂量检查减少18%至37%(P < .001-.03);多因素分析中,患者安全措施追踪系统、支持性放射科领导者和获得清晰图像与高剂量检查减少47%相关。

要点

  • 建立患者安全措施追踪系统、支持性放射科领导者和获得清晰图像与高剂量腹部CT检查减少47%相关。
  • 8项质量改进策略与高剂量腹部CT检查减少18%至37%相关(P < .001-.03)。
  • 辐射剂量在医疗组织和影像中心之间差异很大。

核心结论

  • 质量改进策略与CT检查辐射暴露之间的关系已记录,为其他有兴趣降低患者辐射暴露者提供了重要信息。

研究设计与样本

  • 横断面调查:向放射科领导者发放问卷,同时使用共同剂量管理软件系统测量19个医疗组织、100个影像中心(美国、欧洲和日本)的CT辐射剂量;90个影像中心完成问卷(90%),收集182,415例腹部CT扫描;调整患者年龄、性别和体型后分析质量改进策略与平均腹部CT辐射剂量及高剂量检查几率的关联。

诊断标准与关键数值

  • 单因素分析中8项策略与较低平均剂量或较低高频高剂量腹部CT检查相关:追踪患者安全措施、评估CT变更的影响、识别改进领域、设定具体目标、组织改进团队、根据站点调整决策、在全面实施前测试流程变更、标准化工作流程。
  • 上述流程与高剂量检查减少18%至37%相关(P < .001-.03)。
  • 多因素分析中,患者安全措施追踪系统、支持性放射科领导者和获得清晰图像与高剂量检查减少47%相关。

临床应用与阅片要点

  • 原文结论指出质量改进策略与CT辐射暴露的关系已记录,为其他有兴趣降低患者辐射暴露者提供了重要信息。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to identify organizational factors and quality improvement strategies associated with lower radiation doses from abdominal CT.

METHODS: Cross-sectional survey was administered to radiology leaders, along with simultaneous measurement of CT radiation dose among 19 health care organizations with 100 imaging centers throughout the United States, Europe, and Japan, using a common dose management software system. After adjusting for patient age, gender, and size, quality improvement strategies were tested for association with mean abdominal CT radiation dose and the odds of a high-dose examination.

RESULTS: Completed surveys were received from 90 imaging centers (90%), and 182,415 abdominal CT scans were collected during the study period. Radiation doses varied considerably across organizations and centers. Univariate analyses identified eight strategies and systems that were significantly associated with lower average doses or lower frequency of high doses for abdominal CT examinations: tracking patient safety measures, assessing the impact of CT changes, identifying areas for improvement, setting specific goals, organizing improvement teams, tailoring decisions to sites, testing process changes before full implementation, and standardizing workflow. These processes were associated with an 18% to 37% reduction in high-dose examinations (P < .001-.03). In multivariate analysis, having a tracking system for patient safety measures, supportive radiology leaders, and obtaining clear images were associated with a 47% reduction in high-dose examinations.

CONCLUSIONS: This documentation of the relation between quality improvement strategies and radiation exposure from CT examinations has identified important information for others interested in reducing the radiation exposure of their patients.

来源:J Am Coll Radiol,查看原文。版权归原作者所有。

引用

  1. Solberg LI, Wang Y, Whitebird R, et al. Organizational Factors and Quality Improvement Strategies Associated With Lower Radiation Dose From CT Examinations. J Am Coll Radiol. 2020. PMID: 32192955. doi:10.1016/j.jacr.2020.01.044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。