结直肠癌肝转移大鼠模型中超声肿瘤大小评估、组织学与血清酶分析

Ultrasound Tumor Size Assessment, Histology and Serum Enzyme Analysis in a Rat Model of Colorectal Liver Cancer.
PubMed 文献 · Ultrasound Med Biol · 2020-03-13

研究在大鼠结直肠癌肝植入模型中评估超声预测肿瘤自然坏死的价值,发现血清酶水平在荷瘤与无瘤大鼠间无显著差异,超声测得肿瘤体积与组织学坏死百分比呈强相关(r=0.911),回归方程为肿瘤坏死百分比=21×超声测得肿瘤体积(mL)-3.1。

要点

  • 超声测得肿瘤体积与组织学坏死百分比呈强相关(r=0.911)。
  • 回归方程:肿瘤坏死百分比=21×超声测得肿瘤体积(mL)-3.1。
  • 荷瘤与无瘤大鼠血清酶水平无显著差异。

核心结论

  • 超声是大鼠肝内结直肠癌植入模型中有用的工具。
  • 超声可观察肝内肿瘤(体积范围0.24-1.37 mL)。
  • 第28天超声测得肿瘤体积可用于估计肿瘤植入物自然演变中发生的坏死。

研究设计与样本

  • 研究类型为大鼠肝植入模型实验研究。
  • 在超声引导下将CC531结直肠癌细胞注射至WAG/RijHsd大鼠左肝叶。
  • 细胞接种后28天行超声测量肿瘤体积,处死大鼠获取肿瘤组织及血清。
  • 参考标准为苏木精-伊红染色肿瘤样本中估计的坏死百分比。

关键影像表现/征象

  • 肿瘤植入物表现为边界清晰的高回声区,平均体积0.61 ± 0.39 mL,肿瘤坏死百分比8.6 ± 7.7%。
  • 单因素逻辑回归分析评估肿瘤坏死百分比与超声测得肿瘤体积的关联,并获得线性回归方程。

诊断标准与关键数值

  • 超声测得肿瘤体积与肿瘤坏死百分比的Pearson相关系数r=0.911,呈极强关系。
  • 回归方程为肿瘤坏死百分比=21×超声测得肿瘤体积(mL)-3.1。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

During tumor development, tissue necrosis appears as a natural phenomenon directly associated with an increase in tumor size. The aim of this study was to assess the use of ultrasound (US) for predicting natural tumor necrosis in a rat liver implant model of colorectal cancer. To achieve this goal, we sought to establish a correlation between US-measured tumor volume, serum enzyme levels and histopathological findings, particularly those regarding necrosis phenomena in liver implants. Under US guidance, CC531 colorectal cancer cells were injected into the left liver lobe of WAG/RijHsd rats. Twenty-eight days after cell inoculation, tumor volume was measured by US, and rats were sacrificed to obtain samples of tumor tissue as well as blood serum. In hematoxylin and eosin-stained tumor samples, the percentage of tumor that was necrotic was estimated. The association between percentage tumor necrosis and US-measured tumor volume was assessed by univariate logistic regression analysis, and a linear regression equation was obtained. Serum enzyme levels did not differ significantly between tumor-bearing and tumor-free rats. Tumor implants appeared as well-defined hyper-echoic regions with a mean volume of 0.61 ± 0.39 mL and tumor necrosis percentage of 8.6 ± 7.7%. Linear regression analysis revealed a very strong relationship (Pearson correlation coefficient r = 0.911) between US-measured tumor volume and tumor necrosis percentage; the regression equation was tumor necrosis percentage = 21 × US-measured tumor volume (in mL) - 3.1. The study found US to be a useful tool in animal-based trials. Tumors inside the liver (ranging in volume from 0.24-1.37 mL) can be observed by US, and moreover, US-measured tumor volume on day 28 can be used to estimate tumor necrosis occurring as the natural evolution of tumor implants.