文献速递腹部技术与安全USMR

评估腹部超声与电影磁共振成像检测腹腔粘连的诊断效能:一项双盲研究

Assessment of the diagnostic efficacy of abdominal ultrasonography and cine magnetic resonance imaging in detecting abdominal adhesions: A double-blind research study.
PubMed 文献 · Eur J Radiol · 2020-02-29

该前瞻性双盲队列纳入2017至2019年间108例有腹部手术史的患者,以手术所见为金标准,比较腹部超声与电影磁共振成像检测腹腔粘连的效能。腹部超声总九分区敏感度91.4%、特异度100%、阳性预测值90.7%、阴性预测值100%、诊断准确率87.9%;电影磁共振成像相应为90.8%、100%、90.7%、100%、91.7%。两者检测腹壁粘连无显著差异,但电影磁共振成像检测腹腔内脏器粘连更优;作者认为两者可用于重复手术前规划,以避免肠管损伤。

要点

  • 腹部超声与电影磁共振成像检测腹壁粘连的效能无显著差异。
  • 电影磁共振成像在检测腹腔内脏器粘连方面优于腹部超声。
  • 作者认为两者可用于重复手术前规划,以避免肠管损伤。

核心结论

  • 腹部超声与电影磁共振成像对重复手术患者腹腔粘连的诊断均准确。
  • 两者检测腹壁粘连无显著差异,电影磁共振成像检测腹腔内脏器粘连更优。
  • 作者认为两者可能用于择期腹腔镜或开腹手术规划,以避免肠管损伤。

研究设计与样本

  • 前瞻性双盲队列研究,2017至2019年连续纳入108例有腹部手术史的患者。
  • 检查方法为腹部超声与电影磁共振成像,测量内脏滑动及诱导内脏滑动。
  • 以手术所见为金标准,采用九分区腹部图记录粘连位置与范围,将术前影像与术中所示粘连程度及严重度在同一腹部分区进行关联。

关键影像表现/征象

  • 腹部超声与电影磁共振成像均通过测量内脏滑动及诱导内脏滑动评估粘连。
  • 以九分区腹部图记录粘连的位置和范围。
  • 电影磁共振成像在检测腹腔内脏器粘连方面优于腹部超声,腹壁粘连检测两者无显著差异。

诊断标准与关键数值

  • 按总九分区,腹部超声敏感度91.4%、特异度100%、阳性预测值90.7%、阴性预测值100%、诊断准确率87.9%。
  • 按总分区,电影磁共振成像敏感度90.8%、特异度100%、阳性预测值90.7%、阴性预测值100%、诊断准确率91.7%。

临床应用与阅片要点

  • 作者认为腹部超声与电影磁共振成像可能用于重复手术前规划,以避免肠管损伤。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: This cohort aimed to determine the efficacy and safety of abdominal ulrasonography and cine-MRI by a double-blind study in the diagnosis of intraabdominal organs and abdominal wall adhesions in patients with previous abdominal operations.

METHODS: Between 2017 and 2019, 108 consecutive patients were prospectively included in the study. Visceral slide and induced visceral slide were measured during AU and cine-MRI. An abdominal map consisting of nine segments was created to document the location and extent of the adhesion. The degree and severity of the adhesions detected by the radiologist preoperatively and detected in surgery as the gold standard was recorded in the same abdominal zones. AU, c-MRI and intraoperative findings were correlated.

RESULTS: The mean age was 53.0 ± 10.3 years, body mass index was 30.4 ± 3.4, male (52.8 %) and female (47.2 %). According to the total nine zones, the sensitivity of AU was 91.4 %, specificity was 100 %, positive predictive value was 90.7 %, negative predictive value was 100 % and diagnostic accuracy was 87.9 %. Considering the total zones, the sensitivity of c-MRI was 90.8 %, specificity was 100 %, PPV was 90.7 %, NPV was 100 % and diagnostic accuracy was 91.7 %. A comparison of AU and c-MRI showed no significant difference in the detection of adhesions to the abdominal wall; however, c-MRI was superior in detecting intraabdominal organs adhesion.

CONCLUSION: We have demonstrated that AU and c-MRI are accurate for diagnosing adhesions in patients undergoing repeated surgery and may have a place on planning elective laparoscopic or open surgery to avoid bowel injury.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Yasemin A, Mehmet B, Omer A, et al. Assessment of the diagnostic efficacy of abdominal ultrasonography and cine magnetic resonance imaging in detecting abdominal adhesions: A double-blind research study. Eur J Radiol. 2020. PMID: 32145598. doi:10.1016/j.ejrad.2020.108922

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。