文献速递腹部PETMR

18F-FDG PET/MRI在原发性肝内肿瘤评估中的作用

The Role of 18F-FDG PET/MRI in the Assessment of Primary Intrahepatic Neoplasms.
PubMed 文献 · Acad Radiol · 2020-02-25

回顾性分析39例经病理证实的原发性肝内肿瘤(15例肿块型肝内胆管癌、24例肝细胞癌)的18F-FDG PET/MRI结果,评估其与组织病理亚型和分级的关系。肝内胆管癌中位SUV为6.0,显著高于肝细胞癌的4.0(p=0.002);以SUV 4.41为最佳截断值鉴别两者,AUC为0.79(95%CI 0.649-0.932),敏感度86.7%、特异度67%。作者认为18F-FDG PET/MRI可能有助于预测肿瘤分级并鉴别肝内肿瘤类型。

要点

  • 肝内胆管癌中位SUV 6.0高于肝细胞癌4.0(p=0.002),以SUV 4.41为截断值鉴别两者AUC 0.79。
  • ADC值在肝细胞癌与肝内胆管癌间无显著差异(p=0.283)。
  • 肝细胞癌低级别与高级别间SUV和ADC均差异显著,两者联合鉴别效能达0.929。

核心结论

  • 18F-FDG PET/MRI评估原发性肝内肿瘤可能有助于预测肿瘤分级并鉴别肝内肿瘤类型。

研究设计与样本

  • 回顾性评估39例经组织病理学证实的原发性肝内肿瘤患者的18F-FDG PET/MRI结果,其中肿块型肝内胆管癌15例、肝细胞癌24例。
  • 分析表观扩散系数(ADC)和标准化摄取值(SUV)与组织病理学诊断及组织学分级的关系,并计算影像学表现的敏感度和特异度。

关键影像表现/征象

  • 肝内胆管癌中位SUV为6.0(四分位距5-10),肝细胞癌中位SUV为4.0(四分位距2.62-6.50)。
  • 肝细胞癌与肝内胆管癌的ADC值无显著差异(p=0.283)。
  • 肝细胞癌低级别(高分化及中分化)与高级别(低分化)间SUV和ADC值均差异显著。
  • 肝内胆管癌不同组织学分级间SUV无显著差异(p=0.280),ADC仅在高分化与低分化间差异显著(p=0.004)。

诊断标准与关键数值

  • 以SUV 4.41为最佳截断值鉴别肝内胆管癌与肝细胞癌,AUC为0.79(95%CI 0.649-0.932),敏感度86.7%、特异度67%。
  • 联合ADC与SUV将肝细胞癌低级别与高级别的鉴别提升至显著水平(0.929)。

临床应用与阅片要点

  • 作者认为评估原发性肝内肿瘤时使用18F-FDG PET/MRI可能有助于预测肿瘤分级并鉴别肝内肿瘤类型。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate the results of 18F-FDG PET/MRI in relation to the histopathologic subtypes and histologic grades of mass-forming primary intrahepatic neoplasms.

MATERIALS AND METHODS: We retrospectively evaluated 18F-FDG positron emission tomography/magnetic resonance imaging (PET/MRI) results for 39 patients with histopathologically confirmed primary hepatic neoplasms, 15 with mass-forming intrahepatic cholangiocarcinoma (ICC) and 24 with hepatocellular carcinoma (HCC). The apparent diffusion coefficient (ADC) and standardized uptake value (SUV) were analyzed in relation to the histopathologic diagnosis and histologic grade, including calculating the sensitivity and specificity of the imaging findings.

RESULTS: The median SUV of ICC (6.0 [interquartile range, 5-10]) was significantly higher than that of HCC (4.0 [2.62-6.50]) (p = 0.002). An area under the curve (AUC) of 0.79 (95% confidence interval 0.649-0.932) had a sensitivity of 86.7% and a specificity of 67% at the best cut-off SUV of 4.41 to differentiate between ICC and HCC. ADC values did not differ significantly between HCCs and ICCs (p = 0.283). Both SUV and ADC values differed significantly between low-grade (well- and moderately differentiated) and high-grade (poorly differentiated) HCCs. Combining ADC and SUV further improved differentiation of low- from high-grade HCCs to a significant level (0.929). The SUV did not differ significantly between ICC histologic grades (p = 0.280), while the ADC differed significantly only between well and poorly differentiated ICCs (p = 0.004).

CONCLUSION: Assessing primary hepatic neoplasms with 18F-Fluorodeoxyglucose PET/MRI may help to predict tumor grade and differentiate between types of intrahepatic neoplasms.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Çelebi F, Yaghouti K, Cindil E, et al. The Role of 18F-FDG PET/MRI in the Assessment of Primary Intrahepatic Neoplasms. Acad Radiol. 2020. PMID: 32111468. doi:10.1016/j.acra.2020.01.026

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。