15 mL对比剂时间分辨成像CT血管造影用于腹主动脉瘤腔内修复术前评估
本研究纳入26例造影后急性肾损伤高风险患者,采用15 mL对比剂行时间分辨成像全主动脉CT血管造影(tMIP-CTA)评估EVAR术前规划。全主动脉平均CT值267.5±51.4 HU,图像质量优良者24例(92%),副肾动脉、肠系膜下动脉闭塞及IFU评估一致率均为100%,无患者发生PC-AKI。主动脉容积是与强主动脉强化最显著相关的独立因素(p=0.004)。
要点
- 15 mL对比剂tMIP-CTA可维持全主动脉强化,平均CT值267.5±51.4 HU,满足EVAR术前评估。
- 副肾动脉、肠系膜下动脉闭塞及IFU评估与常规评估一致率均达100%。
- 24例(92%)患者整体图像质量达优良,无患者发生造影后急性肾损伤。
核心结论
- 时间分辨成像全主动脉tMIP-CTA有助于维持EVAR术前规划所需的对比强化和图像质量,并可大幅减少对比剂用量。
研究设计与样本
- 单臂研究,纳入26例造影后急性肾损伤高风险患者,采用15 mL对比剂行时间分辨成像全主动脉CTA并生成tMIP-CTA。
- 测量主动脉-髂动脉CT值,两名观察者于平扫CT与tMIP-CTA上测量动脉直径并以5分制评估图像质量。
- 评估副肾动脉存在、肠系膜下动脉闭塞及EVAR的IFU,并以多因素分析寻找与强主动脉强化相关的独立因素。
关键影像表现/征象
- 全主动脉平均CT值为267.5±51.4 HU,并沿主动脉远端层面逐渐降低。
- 平扫CT与tMIP-CTA对外部动脉直径测量的一致性极佳(Bland-Altman分析)。
- 外部动脉直径测量的观察者间一致性极佳(ICC 0.910-0.992),内部动脉直径测量亦极佳(ICC 0.895-0.993)。
- 24例(92%)患者整体图像质量达优良。
诊断标准与关键数值
- 图像质量采用5分制评估,24例(92%)达优良。
- 副肾动脉存在、肠系膜下动脉闭塞及IFU评估的一致率均为100%。
- 多因素分析显示主动脉容积是与强主动脉强化最显著相关的独立因素(p=0.004)。
临床应用与阅片要点
- 对PC-AKI高风险患者行EVAR术前评估时,15 mL对比剂tMIP-CTA可维持全主动脉强化并提供满足规划需求的图像质量。
- tMIP-CTA与平扫CT在外部及内部动脉直径测量上观察者间一致性极佳,可用于直径测量。
- 副肾动脉、肠系膜下动脉闭塞及IFU评估与常规评估一致率达100%,支持其用于EVAR术前规划。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the utility of whole-aorta CT angiography (CTA) with 15 mL contrast material (CM) on time-resolved imaging for endovascular abdominal aortic repair (EVAR).
METHODS: Twenty-six patients with a high-risk of post-contrast acute kidney injury (PC-AKI) underwent CTA with 15 mL CM using temporal maximum intensity projection (tMIP-CTA) generated from time-resolved imaging. The aortoiliac CT values were measured. Two observers measured the arterial diameters in unenhanced CT and tMIP-CTA images, and image quality was evaluated on a 5-point scale. The presence of the accessory renal artery, inferior mesenteric artery (IMA) occlusion, and instructions for use (IFU) of EVAR were evaluated.
RESULTS: CT examinations were successfully performed, and no patients developed PC-AKI. The mean CT values of the whole aorta were 267.5 ± 51.4 HU, which gradually decreased according to the distal levels of the aorta. Bland-Altman analysis revealed excellent agreement for the external arterial diameter measurements between unenhanced CT and tMIP-CTA. Excellent interobserver agreement was achieved for the measurements of the external (ICCs, 0.910-0.992) and internal arterial diameters (ICCs, 0.895-0.993). Excellent or good overall image quality was achieved in 24 (92 %) patients. The presence of the accessory renal artery, IMA occlusion and the assessment of IFU were in 100 % agreement. Multivariate analysis revealed aortic volume as the most significant independent factor associated with strong aortic enhancement (p = 0.004).
CONCLUSIONS: Whole-aorta tMIP-CTA on time-resolved imaging is useful for maintaining contrast enhancement and image quality for EVAR planning, and can substantially reduce the amount of CM.
引用
- Horinouchi H, Sofue K, Nishii T, et al. CT angiography with 15 mL contrast material injection on time-resolved imaging for endovascular abdominal aortic aneurysm repair. Eur J Radiol. 2020. PMID: 32179423. doi:10.1016/j.ejrad.2020.108861
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。