剪切波超声弹性成像检测腹主动脉瘤腔内修复术后内漏及评估血栓机化的可行性
本研究前瞻性纳入2014年11月至2016年3月行EVAR的患者,随访至2019年3月,用剪切波超声弹性成像(SWS)检测内漏并与CTA和彩色多普勒超声(CDUS)比较。SWS检测内漏敏感度100%,特异度67%,PPV 50%,CDUS敏感度43%;SWS阴性者3年随访未出现新内漏。
要点
- SWS检测EVAR术后内漏敏感度100%,与CTA联合CDUS检出的内漏一致。
- SWS特异度67%、PPV 50%,CDUS敏感度43%,SWS敏感度优于CDUS。
- SWS弹性图可区分内漏与瘤囊内血栓(p < 0.001),SWS阴性者3年随访无新内漏。
关键影像表现/征象
- 基于弹性图,SWS可区分内漏与瘤囊内血栓(p < 0.001)。
- 两名SWS读者检出28例参与者中的7处内漏,读者间一致性k = 0.858。
- 内漏组动脉瘤增长显著大于 sealed AAAs 组。
- AAA增长与血栓弹性或新鲜血栓比例之间无相关性。
- SWS阴性检查者在3年随访中未观察到新内漏。
诊断标准与关键数值
- SWS检测内漏的敏感度为100%,特异度和PPV平均分别为67%和50%。
- CDUS敏感度估计为43%。
临床应用与阅片要点
- SWS弹性图可用于EVAR术后随访中检测内漏,并区分内漏与瘤囊内血栓。
- SWS阴性检查在3年随访中未出现新内漏,提示其可能有助于排除内漏。
- SWS特异度和PPV有限,需结合CTA和CDUS综合判断。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the feasibility of shear wave sonoelastography (SWS) for endoleak detection and thrombus characterization of abdominal aortic aneurysm (AAA) after endovascular repair (EVAR).
MATERIALS AND METHODS: Participants who underwent EVAR were prospectively recruited between November 2014 and March 2016 and followed until March 2019. Elasticity maps of AAA were computed using SWS and compared to computed tomography angiography (CTA) and color Doppler ultrasound (CDUS). Two readers, blinded to the CTA and CDUS results, reviewed elasticity maps and B-mode images to detect endoleaks. Three or more CTAs per participant were analyzed: pre-EVAR, baseline post-EVAR, and follow-ups. The primary endpoint was endoleak detection. Secondary endpoints included correlation between total thrombus elasticity, proportion of fresh thrombus, and aneurysm growth between baseline and reference CTAs. A 3-year follow-up was made to detect missed endoleaks, EVAR complication, and mortality. Data analyses included Cohen's kappa; sensitivity, specificity, and positive predictive value (PPV); Pearson coefficient; and Student's t tests.
RESULTS: Seven endoleaks in 28 participants were detected by the two SWS readers (k = 0.858). Sensitivity of endoleak detection with SWS was 100%; specificity and PPV averaged 67% and 50%, respectively. CDUS sensitivity was estimated at 43%. Aneurysm growth was significantly greater in the endoleak group compared to sealed AAAs. No correlation between growth and thrombus elasticity or proportion of fresh thrombus in AAAs was found. No new endoleaks were observed in participants with SWS negative studies.
CONCLUSION: SWS has the potential to detect endoleaks in AAA after EVAR with comparable sensitivity to CTA and superior sensitivity to CDUS.
KEY POINTS: • Dynamic elastography with shear wave sonoelastography (SWS) detected 100% of endoleaks in abdominal aortic aneurysm (AAA) follow-up that were identified by a combination of CT angiography (CTA) and color Doppler ultrasound (CDUS). • Based on elasticity maps, SWS differentiated endoleaks from thrombi within the aneurysm sac (p < 0.001). • After 3-year follow-up, no new endoleaks were observed in SWS negative examinations.
引用
- Voizard N, Bertrand-Grenier A, Alturkistani H, et al. Feasibility of shear wave sonoelastography to detect endoleak and evaluate thrombus organization after endovascular repair of abdominal aortic aneurysm. Eur Radiol. 2020. PMID: 32130495. doi:10.1007/s00330-020-06739-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。