文献速递心血管MR

左心室整体心肌应变评估:心血管磁共振特征追踪算法在临床环境中是否有用?

Left ventricular global myocardial strain assessment: Are CMR feature-tracking algorithms useful in the clinical setting?
PubMed 文献 · Radiol Med · 2020-03-03

研究纳入45名受试者(15名对照、15名急性心肌梗死、15名非缺血性扩张型心肌病),比较手动轮廓法与国际上四款心血管磁共振特征追踪(CMR-FT)软件测量的整体径向、圆周和纵向应变。手动法观察者内和观察者间一致性极佳,但手动法与CMR-FT软件间一致性从差到极佳不等,圆周应变一致性最好,径向和纵向应变在部分软件中明显被系统性低估。

要点

  • 手动轮廓法测量整体应变具有极佳的观察者内和观察者间一致性。
  • 手动法与CMR-FT软件测量应变的一致性因软件和应变方向而异,圆周应变一致性最好。
  • 部分软件在径向和纵向应变上存在系统性低估,与手动法相关性差至中等,临床使用需谨慎。

诊断标准与关键数值

  • 手动轮廓法观察者内一致性ICC为0.903(GRS)至0.995(GCS),观察者间一致性ICC为0.915(GRS)至0.966(GCS)。
  • 手动轮廓法观察者内CV为4.7%(GCS)至20.7%(GRS),观察者间CV为12.7%(GCS)至20.0%(GRS)。
  • 手动法与CMR-FT法间一致性从差到极佳不等:GCS的ICC为0.857-0.935,GLS的ICC为0.591-0.914,GRS的ICC为0.271-0.851。
  • 两款软件包在径向和纵向方向上显示系统性低估心肌应变的强烈趋势,与手动轮廓法相关性差至中等:GRS的ICC为0.271、CV为25.2%;GLS的ICC为0.591、CV为17.6%。

临床应用与阅片要点

  • 作者认为,部分CMR-FT软件包测得的应变值与手动法一致性差,在临床环境中使用这些软件包需谨慎。
  • 作者指出,以手动推导的应变为参考时,径向和纵向应变在使用部分软件包时倾向于被低估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Myocardial strains can be calculated using cardiovascular magnetic resonance (CMR) feature-tracking (FT) algorithms. They show excellent intra- and inter-observer agreement but rather disappointing inter-vendor agreement. Currently, it is unknown how well CMR-FT-based strain values agree with manually obtained strain values.

METHODS: In 45 subjects (15 controls, 15 acute myocardial infarction, 15 non-ischemic dilated cardiomyopathy), end-systolic manually derived strains were compared to four CMR-FT software packages. Global radial strain (GRS), global circumferential strain (GCS) and global longitudinal strain (GLS) were determined. Intra- and inter-observer agreement and agreement between manual and CMR-FT analysis were calculated. Statistical analysis included Bland-Altman plots, intra-class correlation coefficient (ICC) and coefficient of variation (CV).

RESULTS: Manual contouring yielded excellent intra-observer (ICC 0.903 (GRS) to 0.995 (GCS)) and inter-observer agreement (ICC 0.915 (GRS) to 0.966 (GCS)) with CV ranging 4.7% (GCS) to 20.7% (GRS) and 12.7% (GCS) to 20.0% (GRS), for intra-observer and inter-observer agreement, respectively. Agreement between manual and CMR-FT strain values ranged from poor to excellent, with best agreement for GCS (ICC 0.857-0.935) and intermediate for GLS (ICC 0.591-0.914), while ICC values for GRS ranged widely (ICC 0.271-0.851). In particular, two software packages showed a strong trend toward systematic underestimation of myocardial strain in radial and longitudinal direction, correlating poorly to moderately with manual contouring, i.e., GRS (ICC 0.271, CV 25.2%) and GLS (ICC 0.591, CV 17.6%).

CONCLUSION: Some CMR-FT values agree poorly with manually derived strains, emphasizing to be cautious to use these software packages in the clinical setting. In particular, radial and longitudinal strain tends to be underestimated when using manually derived strains as reference.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Pierpaolo P, Rolf S, Manuel BP, et al. Left ventricular global myocardial strain assessment: Are CMR feature-tracking algorithms useful in the clinical setting? Radiol Med. 2020. PMID: 32125636. doi:10.1007/s11547-020-01159-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。