文献速递心血管MR

多参数定量心脏磁共振在暴发性心肌炎心肌损伤检测与监测中的应用

Application of Multiparametric Quantitative Cardiac Magnetic Resonance for Detection and Monitoring of Myocardial Injury in Patients with Fulminant Myocarditis.
PubMed 文献 · Acad Radiol · 2020-03-18

研究纳入19例临床诊断暴发性心肌炎患者(35±14岁,37%男性),在急性期和3个月随访时进行3.0T心脏磁共振检查,对照组为19名健康志愿者。结果显示多参数心脏磁共振可检测和监测暴发性心肌炎的炎症性心肌损伤,原生T1和T2值在区分急性期与愈合期心肌炎方面具有优异诊断性能(AUC分别为0.947和0.931)。

要点

  • 原生T1和T2值区分急性期与愈合期暴发性心肌炎的AUC分别为0.947和0.931。
  • 急性期所有定量炎症指标包括水肿率、LGE质量、原生T1、T2和细胞外容积均显著高于对照组,随访时显著下降但仍高于对照组。
  • 急性期整体应变指标包括圆周、纵向和径向应变值均较对照组显著受损。

关键影像表现/征象

  • 急性期左心室质量指数(67±15 vs 55±12 g/m2,p<0.05)和室间隔厚度(10.4±1.5 vs 8.3±1.8 mm,p<0.001)显著高于对照组,慢性期恢复正常。
  • 随访扫描中所有定量炎症指标包括水肿率、LGE质量、原生T1、T2和细胞外容积均显著下降(均p<0.001),但仍高于对照组。
  • 与对照组相比,急性期所有整体应变指标包括圆周、纵向和径向应变值均显著受损(均p<0.001)。

诊断标准与关键数值

  • 原生T1值区分暴发性心肌炎与愈合期心肌炎的AUC为0.947。
  • T2值区分暴发性心肌炎与愈合期心肌炎的AUC为0.931。

临床应用与阅片要点

  • 原生T1和T2值可用于区分急性期与愈合期暴发性心肌炎,AUC分别为0.947和0.931。
  • 急性期左心室质量指数和室间隔厚度显著高于对照组,慢性期恢复正常。
  • 随访时定量炎症指标包括水肿率、LGE质量、原生T1、T2和细胞外容积较急性期显著下降但仍高于对照组。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To investigate whether multiparametric cardiac magnetic resonance (CMR) could detect and monitor inflammatory myocardial alterations in fulminant myocarditis.

MATERIALS AND METHODS: Nineteen patients (35 ± 14 years, 37% male) with clinical diagnosis of fulminant myocarditis underwent CMR examinations at 3.0T in the acute phase and at 3-months follow up. The control group consisted of 19 healthy volunteers. The CMR protocol included cine, black blood T2-weighted imaging, T1 mapping, T2 mapping and late gadolinium enhancement (LGE). Cardiac parameters, such as edema ratio, LGE mass, native T1, T2 and extracellular volume were measured.

RESULTS: The left ventricular mass index (67 ± 15 versus 55 ± 12 g/m2, p < 0.05) and interventricular septum thickness (10.4 ± 1.5 versus 8.3 ± 1.8 mm, p < 0.001) in acute stage was significantly higher compared to controls, and normalized at the chronic stage. All quantitative inflammation metrics, including edema ratio, LGE mass, native T1, T2 and extracellular volume were significantly (all p < 0.001) decreased in the follow-up scan, but still higher compared to controls. Compared to the controls, all global strain indices including circumferential, longitudinal and radial strain values were significantly impaired in acute stage (all p < 0.001). Native T1 and T2 values led to excellent diagnostic accuracy for discriminating fulminant myocarditis from healed myocarditis, with AUC of 0.947 and 0.931.

CONCLUSION: Multiparametric CMR could detect and monitor inflammation myocardial injuries in patients with fulminant myocarditis. Native T1 and T2 values achieved excellent diagnostic performance in distinguishing acute from healed myocarditis.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Li H, Zhu H, Yang Z, et al. Application of Multiparametric Quantitative Cardiac Magnetic Resonance for Detection and Monitoring of Myocardial Injury in Patients with Fulminant Myocarditis. Acad Radiol. 2020. PMID: 32199722. doi:10.1016/j.acra.2020.01.034

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。