再灌注急性心肌梗死水肿的MRI:ADC定量与T1、T2 mapping的比较
本前瞻性研究于2016年6月至2018年11月纳入34例首次急性心肌梗死再灌注后患者,用1.5-T MRI行ADC mapping与T1、T2 mapping定量比较。结果显示梗死区ADC均值2.32×10-3 mm2/sec、边界区1.91×10-3 mm2/sec、远隔区1.62×10-3 mm2/sec(P<.001);扩散加权MRI显示水肿的归一化信号差异分别为T1、T2 map的5.1倍和3.5倍(P<.001),ADC mapping较T1或T2 mapping显示远隔区与病灶间差异更大。
要点
- 梗死区ADC均值2.32×10-3 mm2/sec,边界区1.91×10-3 mm2/sec,远隔区1.62×10-3 mm2/sec,三区间差异有统计学意义(P<.001)。
- 梗死区与远隔区归一化信号差异:扩散加权MRI分别为T1 map的5.1倍和T2 map的3.5倍(P<.001)。
- 多层面心脏扩散加权成像可在急性心肌损伤患者中完成采集。
核心结论
- 多层面心脏扩散加权图像可在急性心肌损伤患者中采集,定量ADC mapping显示的远隔区与病灶间差异大于T1或T2 mapping。
研究设计与样本
- 前瞻性研究,2016年6月至2018年11月纳入34例无心力衰竭或心肌病病史、首次急性心肌梗死再灌注后患者。
- 采用1.5-T MRI扫描仪行定量T1、T2 mapping,并与快速自由呼吸ADC mapping技术比较(约3分钟、5层、自旋回波心脏扩散采集、b值0和200 sec/mm2、6个扩散编码方向、5次重复)。
- 再灌注后平均5天±1.9(标准差)行MRI检查。
- 采用Welch方差分析及Games-Howell事后检验进行梗死区、边界区与远隔区的两两比较。
关键影像表现/征象
- 梗死区ADC均值2.32×10-3 mm2/sec(95%CI:2.28,2.36),边界区1.91×10-3 mm2/sec(95%CI:1.89,1.94),两者比较P<.001。
- 远隔区ADC均值1.62×10-3 mm2/sec(95%CI:1.59,1.64),与健康志愿者体内测得值相当。
- 同一感兴趣区内,梗死区与远隔区T1均值分别为1332 msec(95%CI:1296,1368)与1045 msec(95%CI:1034,1056),P<.001。
- 同一感兴趣区内,梗死区与远隔区T2均值分别为72 msec(95%CI:69,75)与50 msec(95%CI:49,51),P<.001。
诊断标准与关键数值
- ADC定量比较对象为梗死区、边界区与远隔区,梗死区与边界区比较P<.001。
- T1、T2定量比较对象为同一感兴趣区内的梗死区与远隔区,均P<.001。
- 归一化信号差异以梗死区与远隔区比较,扩散加权MRI显示水肿分别为T1 map的5.1倍(P<.001)和T2 map的3.5倍(P<.001)。
临床应用与阅片要点
- 作者结论认为多层面心脏扩散加权图像可在急性心肌损伤患者中采集,定量ADC mapping显示的远隔区与病灶间差异大于T1或T2 mapping。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background After acute myocardial infarction (AMI), reperfusion injury is associated with microvascular lesions and myocardial edema. Purpose To evaluate the performance of apparent diffusion coefficient (ADC) quantification compared with T1 and T2 values in the detection of acute myocardial injury. Materials and Methods In this prospective study conducted from June 2016 to November 2018, participants without a history of heart failure or cardiomyopathy were enrolled after undergoing reperfusion for their first AMI. Quantitative T1 and T2 mapping were performed with a 1.5-T MRI scanner and compared with a fast free-breathing acquisition technique for ADC mapping (approximate duration, 3 minutes; five slices; spin-echo cardiac diffusion acquisition; b values, 0 and 200 sec/mm2; six diffusion-encoding directions; five repetitions). Quantitative ADC and unenhanced T1 and T2 values were compared in infarct, border, and remote regions by using Welch analysis of variance with Games-Howell post hoc test for pairwise comparisons. Results Thirty-four participants with AMI underwent MRI an average of 5 days ± 1.9 (standard deviation) after reperfusion. Mean ADC was markedly high in the infarcted regions (2.32 × 10-3 mm2/sec; 95% confidence interval [CI]: 2.28, 2.36) and moderately high in the border regions (1.91 ×10-3 mm2/sec; 95% CI: 1.89, 1.94; P < .001). In remote regions, mean ADC (1.62 ×10-3 mm2/sec; 95% CI: 1.59, 1.64) was comparable to that measured in vivo in healthy volunteers. Within the same regions of interest, although the measures showed similar trends in infarct and remote regions for T1 (mean, 1332 mec [95% CI: 1296, 1368] vs 1045 msec [95% CI: 1034, 1056]; P < .001) and T2 (72 msec [95% CI: 69, 75] vs 50 msec [95% CI: 49, 51]; P < .001), the magnitude of the differences among regions was greater when using ADC. Normalized signal differences between infarct and remote regions showed that diffusion-weighted MRI depicted edema 5.1 (P < .001) and 3.5 (P < .001) times greater than did T1 and T2 maps, respectively. Conclusion Multislice cardiac diffusion-weighted images could be acquired in those with acute myocardial injury. Quantitative apparent diffusion coefficient mapping showed greater differences among remote regions and lesions than did T1 or T2 mapping. © RSNA, 2020 See also the editorial by Lloyd and Farris in this issue.
引用
- Moulin K, Viallon M, Romero W, et al. MRI of Reperfused Acute Myocardial Infarction Edema: ADC Quantification versus T1 and T2 Mapping. Radiology. 2020. PMID: 32208095. doi:10.1148/radiol.2020192186
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。