冠状动脉钙化积分扫描能否降低冠状动脉CT血管造影的辐射剂量?
本研究纳入256例患者,比较使用冠状动脉钙化积分扫描(CACS)与定位像规划视野对CCTA扫描长度、剂量长度乘积(DLP)及总辐射暴露(ORE)的影响。结果显示CACS可缩短扫描长度并降低DLP,但CACS导致两组ORE均增加,作者认为CACS在降低CCTA扫描辐射剂量方面可能有重要作用,但降低ORE的潜在效果较弱。
要点
- 使用CACS规划视野可缩短CCTA扫描长度并降低DLP,但会增加总辐射暴露(ORE)。
- 第三代双源CT组扫描长度9.98±0.79 cm vs 13.64±1.79 cm(p<0.001),DLP 115.04±64.13 vs 138.67±68.87(p<0.05)。
- 256排CT组扫描长度14.92±1.17 cm vs 15.79±0.63 cm(p=0.001),DLP 322.07±45.39 vs 354.34±65.27(p=0.036)。
诊断标准与关键数值
- A组扫描长度9.98±0.79 cm vs A1组13.64±1.79 cm(p<0.001),A组DLP 115.04±64.13 vs A1组138.67±68.87(p<0.05)。
- B组扫描长度14.92±1.17 cm vs B1组15.79±0.63 cm(p=0.001),B组DLP 322.07±45.39 vs B1组354.34±65.27(p=0.036)。
- CACS导致两组总辐射暴露(ORE)均增加。
临床应用与阅片要点
- 作者认为CACS可能在降低CCTA扫描辐射剂量方面有重要作用,但降低ORE的潜在效果较弱。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: Radiation exposure from coronary computed tomography angiography (CCTA) remains a cause for concern. The objective of this study was to investigate whether using the coronary artery calcium score scan (CACS) would reduce the radiation dose for CCTA scanning and the overall radiation exposure (ORE).
MATERIALS AND METHODS: In total, 256 patients were examined with a third-generation dual-source CT (n = 200) or 256-row CT (n = 56), among whom 105 (Group A) and 28 patients (Group B), respectively, underwent CCTA with CACS for field of view planning. The remaining patients, with the scout view for field of view planning, constituted Group A1 and B1. The scanning parameter settings were standardized between groups.
RESULTS: Shorter scan lengths were observed in Group A (9.98 ± 0.79 cm) compared to Group A1 (13.64 ± 1.79 cm; p < 0.001), which also resulted in a lower dose-length product (DLP) in Group A (115.04 ± 64.13) relative to Group A1 (138.67 ± 68.87; p < 0.05). Similarly, shorter scan lengths were found in Group B (14.92 ± 1.17 cm) compared to Group B1 (15.79 ± 0.63 cm; p = 0.001); this resulted in a lower DLP (322.07 ± 45.39) compared to Group B1 (354.34 ± 65.27; p = 0.036). The CACS resulted in an increase in ORE in both groups.
CONCLUSION: CACS may have a critical role in the reduction of radiation dose in CCTA scanning, but the potential effectiveness of CACS in reducing ORE is weak.
引用
- Jin L, Gao Y, Jiang A, et al. Can the Coronary Artery Calcium Score Scan Reduce the Radiation Dose in Coronary Computed Tomography Angiography? Acad Radiol. 2020. PMID: 32209277. doi:10.1016/j.acra.2020.02.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。