文献速递心血管USMR

超声心动图评估三尖瓣反流与心血管磁共振的对比

Comparison of Echocardiographic Assessment of Tricuspid Regurgitation Against Cardiovascular Magnetic Resonance.
PubMed 文献 · JACC Cardiovasc Imaging · 2020-03-18

本研究在337例患者中比较超声心动图各方法与心血管磁共振(CMR)测量的三尖瓣反流容积(TRRV)。超声参数对CMR TRRV的准确性不一(AUC 0.58~0.79),2017年美国超声心动图学会多参数标准与CMR分级一致率65%,基于可行性及准确性更高信号的分层方法一致率68%且未漏诊CMR重度TR,分层方法一致率高于2017年指南(p=0.016)。

要点

  • 超声各单项参数对CMR TRRV的AUC为0.58(反流束面积/右房收缩末期面积)至0.79(肝静脉血流)。
  • 2017年美国超声心动图学会多参数标准与CMR三尖瓣反流分级一致率为65%。
  • 基于可行性与准确性更高信号的分层方法与CMR一致率68%,未漏诊CMR重度TR,高于2017年指南(p=0.016)。

核心结论

  • 多个超声心动图单项参数对CMR测得的TRRV具有令人满意的准确性,基于可行性与准确性更高信号的分层多参数方法与CMR一致率68%,若允许1级分级差异则一致率达100%。

研究设计与样本

  • 在337例患者中对比超声心动图与CMR方法;超声方法包括反流束大小、肝静脉血流、下腔静脉直径、下腔静脉直径随吸气百分比变化、右房收缩末期面积和容积、右室舒张末期和收缩末期面积及面积变化分数、缩流颈直径、有效反流口面积及近端等速表面积法TRRV;CMR的TRRV为右室舒张末期与收缩末期容积之差减去收缩期通过肺动脉瓣的血流。

诊断标准与关键数值

  • 超声各参数对CMR TRRV的AUC范围为0.58(反流束面积/右房收缩末期面积)至0.79(肝静脉血流);2017年美国超声心动图学会多参数标准与CMR TR分级一致率65%;基于可行性与准确性更高信号的分层方法与CMR一致率68%,且未漏诊CMR重度TR,与CMR一致率高于2017年美国超声心动图学会指南(p=0.016);若允许1级TR分级差异,分层方法与CMR一致率达100%。

临床应用与阅片要点

  • 作者采用基于可行性与准确性更高信号的分层多参数方法评估TR严重程度,其结果与CMR一致率高于2017年美国超声心动图学会指南方法(68% vs 65%,p=0.016),且未漏诊CMR重度TR。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The aim of this study was to compare echocardiographic methods of determining tricuspid regurgitation (TR) severity against TR regurgitant volume (TRRV) by cardiovascular magnetic resonance (CMR).

BACKGROUND: TR is usually assessed using echocardiography, but it is not known how this compares with quantitative measurements of TR severity by CMR.

METHODS: Echocardiographic and CMR methods were compared in 337 patients. Echocardiographic methods included jet size, hepatic vein flow, inferior vena cava diameter, percentage change in inferior vena cava diameter with inspiration, right atrial end-systolic area and volume, right ventricular end-diastolic and end-systolic areas and fractional area change, vena contracta diameter, effective regurgitant orifice area, and TRRV using the proximal isovelocity surface area method. TRRV by CMR was calculated as the difference between right ventricular end-diastolic and end-systolic volumes and systolic flow through the pulmonic valve.

RESULTS: Echocardiographic parameters of TR severity had variable accuracy against TRRV by CMR (area under the curve range 0.58 for jet area/right atrial end-systolic area to 0.79 for hepatic vein flow). A multiparametric approach to assessing TR severity according to the 2017 American Society of Echocardiography criteria had 65% agreement with TR severity by CMR. A hierarchal approach based on signals with higher feasibility and accuracy against CMR had 68% agreement, without missing cases of severe TR by CMR. Agreement with CMR by the hierarchal approach was higher than that by the 2017 American Society of Echocardiography guidelines (p = 0.016).

CONCLUSIONS: Several individual echocardiographic parameters of TR severity have satisfactory accuracy against TRRV by CMR. A multiparametric hierarchal approach resulted in 68% agreement with CMR and 100% agreement when a 1-grade difference in TR severity is considered acceptable.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Zhan Y, Senapati A, Vejpongsa P, et al. Comparison of Echocardiographic Assessment of Tricuspid Regurgitation Against Cardiovascular Magnetic Resonance. JACC Cardiovasc Imaging. 2020. PMID: 32199838. doi:10.1016/j.jcmg.2020.01.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。