光谱CT与肺灌注显像诊断急性和慢性肺栓塞的系统文献综述与Meta分析
本系统综述与Meta分析检索2006年1月1日至2019年2月7日文献,以肺通气-灌注显像为参考标准,评估光谱CT肺动脉造影诊断急性或慢性肺栓塞及慢性血栓栓塞性肺动脉高压的准确性。共纳入6篇文章,其中4篇适合Meta分析,合并敏感度94.2%(95%CI 88.3-100%),合并特异度88.5%(95%CI 81.3-95.6%),阳性预测值87.8%(95%CI 80.3-95.4%),阴性预测值94.5%(95%CI 89.3-99.7%)。作者认为数据有限,慢性肺栓塞/慢性血栓栓塞性肺动脉高压证据较好,急性肺栓塞尚无确切结论,需更大样本前瞻性研究。
要点
- 光谱CT肺动脉造影诊断肺栓塞或慢性血栓栓塞性肺动脉高压的灌注缺损合并敏感度94.2%、特异度88.5%。
- 纳入研究数量少且存在方法学问题,参考标准不一,急性肺栓塞尚无确切结论。
- 作者认为需更大样本前瞻性研究,采用包含先进CT肺动脉造影和肺通气-灌注显像的稳健复合参考标准。
核心结论
- 光谱CT肺动脉造影用于肺栓塞/慢性血栓栓塞性肺动脉高压的数据仍有前景但有限,仅有的小样本研究存在方法学问题。
- 慢性肺栓塞/慢性血栓栓塞性肺动脉高压证据最佳,急性肺栓塞无法得出确切结论。
- 作者认为需更大样本前瞻性研究,采用包含先进CT肺动脉造影和肺通气-灌注显像的稳健复合参考标准。
研究设计与样本
- 系统文献综述与Meta分析,检索PubMed、Embase、Scopus和Web of Science 2006年1月1日至2019年2月7日文献。
- 纳入标准为患者超过10例、年龄超过18岁、诊断结局为肺栓塞或慢性血栓栓塞性肺动脉高压、以肺通气-灌注显像为参考标准。
- 采用QUADAS-2工具评估偏倚与适用性,Meta分析采用Mantel和Haenszel固定效应模型,异质性采用I平方统计量评估。
- 共识别493条唯一记录,标题筛选后53篇进入摘要和全文评估,最终纳入6篇文章,其中4篇适合Meta分析。
诊断标准与关键数值
- 以肺通气-灌注显像为参考标准,光谱CT肺动脉造影诊断肺栓塞或慢性血栓栓塞性肺动脉高压的合并敏感度为94.2%(95%CI 88.3-100%)。
- 合并特异度为88.5%(95%CI 81.3-95.6%)。
- 阳性预测值为87.8%(95%CI 80.3-95.4%),阴性预测值为94.5%(95%CI 89.3-99.7%)。
临床应用与阅片要点
- 作者认为光谱CT肺动脉造影对肺栓塞或慢性血栓栓塞性肺动脉高压患者灌注缺损具有高敏感度和特异度。
- 作者认为慢性肺栓塞/慢性血栓栓塞性肺动脉高压证据最佳,急性肺栓塞尚无确切结论。
- 作者认为需更大样本前瞻性研究,采用包含先进CT肺动脉造影和肺通气-灌注显像的稳健复合参考标准。
局限性
- 仅有的小样本研究存在方法学问题,证据有限。
- 纳入研究参考标准存在多样性。
- 急性肺栓塞无法得出确切结论。
- 作者认为需更大样本前瞻性研究,采用更稳健的复合参考标准。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To examine the diagnostic accuracy of spectral CT pulmonary angiography (S-CTPA) using ventilation-perfusions lung scintigraphy (V/Q-scan) as a reference standard in the diagnosis of acute or chronic pulmonary embolism (APE/CPE) and chronic thromboembolic pulmonary hypertension (CTEPH).
METHODS: PubMed, Embase, Scopus, and Web of Science were searched for the period from 1 Jan 2006 to 7 Feb 2019; eligible studies had > 10 patients over 18 years old, a diagnostic outcome of PE or CTEPH, and used V/Q scan as a reference standard. Bias and applicability were assessed using QUADAS-2 tools. Sensitivities, specificities, and predictive values were noted or calculated from available information. Meta-analysis employed a fixed-effects model of Mantel and Haenszel. Heterogeneity was assessed with I-squared statistics.
RESULTS: Four hundred ninety-three unique records were identified. Following screening by title, 53 studies were included in the abstract and full-text assessment. A total of six articles were included; four were suitable for a meta-analysis. Pooled sensitivity was 94.2% (95% CI, 88.3-100%), pooled specificity was 88.5% (95% CI, 81.3-95.6%), and positive and negative predictive values were 87.8% (95% CI, 80.3-95.4%) and 94.5% (95% CI, 89.3-99.7%), respectively.
CONCLUSION: Data on S-CTPA for PE/CTEPH remains promising, but limited; only small studies with methodological issues are available. Evidence is best for CPE/CTEPH whereas no firm conclusions are possible for APE. There is a need for larger, prospective studies with a robust composite reference standard including state-of-the-art CTPA and V/Q-scans.
KEY POINTS: • S-CTPA has high sensitivity and specificity for perfusion defects in patients with PE or CPETH. • Methodological issues and diversity of reference standards were found in the small number of included studies. • There is a need for larger prospective studies with more robust composite reference standards.