3.0-T PET/MRI 中肺癌的扩散加权成像体素匹配分析:反向相位编码方法校正回波平面成像几何畸变
这项前瞻性研究在3.0-T PET/MRI上采用反向相位编码校正扩散加权成像几何畸变,先在体模验证,再对12例疑似肺癌患者行FDG PET/MRI。体模中高畸变区域平均误差从-25%±10.6降至-18.4%±12.6(P<.001),误差超过20%的体素比例从85.3%降至31.4%;患者多模态肿瘤数据配准改善0.4%-44%,全部肿瘤ADC与SUV体素相关呈零或弱单调关系(平均rs=0.016±0.24,均未超过0.5)。
要点
- 反向相位编码可校正DWI几何畸变,改善PET/MRI体素匹配分析。
- 体模高畸变区平均误差由-25%±10.6降至-18.4%±12.6(P<.001)。
- 全部肿瘤ADC与SUV体素相关呈零或弱单调关系(平均rs=0.016±0.24)。
诊断标准与关键数值
- 体模高畸变区域校正后平均误差为-18.4%±12.6,较校正前的-25%±10.6降低(P<.001)。
- 体模高畸变区域误差超过20%的体素比例由85.3%降至31.4%。
- 12例患者多模态PET/MRI肿瘤数据配准改善范围为0.4%-44%。
- 全部肿瘤ADC与SUV体素相关呈零或弱单调关系,平均rs为0.016±0.24,均未超过0.5。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background PET/MRI has drawn increasing interest in thoracic oncology due to the simultaneous acquisition of PET and MRI data. Geometric distortions related to diffusion-weighted imaging (DWI) limit the evaluation of voxelwise multimodal analyses. Purpose To assess the effectiveness of reverse phase encoding in correcting DWI geometric distortion for multimodal PET/MRI voxelwise lung tumor analyses. Materials and Methods In this prospective study, reverse phase encoding method was implemented with 3.0-T PET/MRI to correct geometric distortions related to DWI. The method was validated in dedicated phantom and then applied to 12 consecutive patients (mean age, 66 years ± 13 [standard deviation]; 10 men) suspected of having lung cancer who underwent fluorodeoxyglucose PET/MRI between October 2018 and April 2019. The effects on DWI-related image matching and apparent diffusion coefficient (ADC) regional map computation were assessed. Consequences on multimodal PET/MRI voxelwise lung tumor analyses were evaluated. Spearman correlation coefficients (rs) between the standardized uptake value (SUV) and ADC data corrected for distortion were computed from optimal realigned DWI PET data, along with bootstrap confidence intervals. Results Phantom results showed that in highly distorted areas, correcting the distortion significantly reduced the mean error against the ground truth (-25% ± 10.6 to -18.4% ± 12.6; P < .001) and the number of voxels with more than 20% error (from 85.3% to 31.4%). In the 12 patients, the coregistration of multimodal PET/MRI tumor data was improved by using the reverse phase encoding method (0.4%-44%). In all tumors, voxelwise correlations (rs) between ADC and SUV revealed null or weak monotonic relationships (mean rs of 0.016 ± 0.24 with none above 0.5). Conclusion Reverse phase encoding is a simple-to-implement method for improved diffusion-weighted multimodal PET/MRI voxelwise-matched analyses in lung cancer. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Colletti in this issue.
引用
- Besson FL, Fernandez B, Faure S, et al. Diffusion-weighted Imaging Voxelwise-matched Analyses of Lung Cancer at 3.0-T PET/MRI: Reverse Phase Encoding Approach for Echo-planar Imaging Distortion Correction. Radiology. 2020. PMID: 32208099. doi:10.1148/radiol.2020192013
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。