基于单指数与双指数模型扩散加权成像对肺结节及肿块良恶性诊断的价值
研究纳入CT上大于1.5 cm的肺病灶121例(恶性88例、良性33例),行DWI(10个b值,0-1000 s/mm²)并计算ADCmean、ADCmin及IVIM参数D、D*、f。结论:鉴别肺结节良恶性时ADCmean最稳健(阈值1.43×10⁻³ mm²/s,敏感度88.57%、特异度64.29%),鉴别肺肿块良恶性时D最稳健(阈值1.23×10⁻³ mm²/s,敏感度90.57%、特异度89.47%)。
要点
- 肺结节良恶性鉴别以ADCmean最稳健,阈值1.43×10⁻³ mm²/s,敏感度88.57%、特异度64.29%。
- 肺肿块良恶性鉴别以D值最稳健,阈值1.23×10⁻³ mm²/s,敏感度90.57%、特异度89.47%。
- 恶性肺结节ADCmean显著低于良性(t=3.156,p=0.006),其余参数无显著差异(p=0.162-0.690)。
核心结论
- ADC是鉴别肺结节良恶性最稳健的参数,而D是鉴别肺肿块良恶性最稳健的参数。
研究设计与样本
- 研究纳入2015年8月至2018年9月间CT上测量大于1.5 cm的肺病灶,最终入组121例患者、每例一个病灶。
- 行DWI扫描(10个b值,0-1000 s/mm²),后处理得出ADCmean、ADCmin及IVIM参数D、D*、f。
- 采用独立样本t检验或Mann-Whitney U检验比较良恶性参数,生成ROC曲线并行Z检验。
诊断标准与关键数值
- 121个病灶中恶性88个(72.7%)、良性33个(27.3%)。
- 恶性肺结节ADCmean显著低于良性肺结节(t=3.156,p=0.006),其余参数无显著差异(p=0.162-0.690)。
- 肺结节:ADCmean阈值1.43×10⁻³ mm²/s,敏感度88.57%、特异度64.29%。
- 肺肿块:恶性者ADCmean、ADCmin、D及D*值均显著低于良性(P﹤0.001-0.011),其中D值诊断性能最佳,阈值1.23×10⁻³ mm²/s,敏感度90.57%、特异度89.47%(Z=2.230、3.958、2.877,p=0.026、﹤0.001、0.004)。
临床应用与阅片要点
- 作者以3 cm为界将病灶分为肺结节与肺肿块,阅片时可据此选择ADCmean或D值作为鉴别良恶性的主要参数。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The objective is to compare the efficacy of diffusion-weighted imaging (DWI) parameters of mean and minimum apparent diffusion coefficient (ADCmean and ADCmin) and intravoxel incoherent motion (IVIM) in the differentiation of benign and malignant lung nodules and masses.
METHODS: Lung lesions measured larger than 1.5 cm on CT were included between August 2015 and September 2018. DWI (10 b-values, 0-1000 s/mm2) scans were performed, and the data were post-processed to derive the ADCmean, ADCmin and IVIM parameters of true diffusion coefficient (D), pseudodiffusion coefficient (D*) and perfusion fraction (f). An independent sample t-test or Mann-Whitney U test was used to compare benign and malignant parameters. Receiver operating characteristic curves were generated and a Z test was used.
RESULTS: 121 patients were finally enrolled, each with one lesion. Examined 121 lesions were malignant in 88 (72.7%) and benign in 33 (27.3%). The ADCmean of malignant pulmonary nodules was significantly lower than that of benign pulmonary nodules (t = 3.156, p = 0.006), whereas the other parameters revealed no significant differences (p = 0.162-0.690). Receiver operating characteristic curve analysis revealed that an ADCmean threshold value of 1.43 × 10-3 mm2/s yielded 88.57% sensitivity and 64.29% specificity. While for lung masses, the ADCmean, ADCmin, D and D* values in malignant pulmonary masses were significantly lower (P﹤0.001-0.011). Among them, the D value exhibited the best diagnostic performance when the threshold of D was 1.23 × 10-3mm2/s, which yielded a sensitivity of 90.57% and a specificity of 89.47% (Z = 2.230, 3.958, 2.877 and p = 0.026, ﹤0.001 and 0.004, respectively).
CONCLUSION: ADC is the most robust parameter to differentiate benign and malignant lung nodules, whereas D is the most robust parameter to differentiate benign and malignant lung masses.
ADVANCES IN KNOWLEDGE: This is the first study to compare all the quantitative parameters of DWI and IVIM mentioned in the literatures for assessing lung lesions; Second, we divided the lesions into lung nodules and lung masses with the size of 3 cm as the boundary.
引用
- Jiang J, Fu Y, Hu X, et al. The value of diffusion-weighted imaging based on monoexponential and biexponential models for the diagnosis of benign and malignant lung nodules and masses. Br J Radiol. 2020. PMID: 32163295. doi:10.1259/bjr.20190400
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。