典型肺类癌的诊断影像学:MDCT、111In-Octreoscan与18F-FDG-PET影像特征和Ki-67指数的关系
本研究分析68例经组织学诊断的肺典型类癌患者,术前分期评估均行增强MDCT、111In-喷曲肽SPECT和18F-FDG-PET/CT。结果显示Ki-67指数与肿瘤/非肿瘤比值(T/NT%)负相关、与FDG摄取比正相关,部分MDCT征象和核医学特征与Ki-67分级显著相关。
要点
- 典型类癌多数表现为边界清楚的结节,增强明显,可伴钙化或支气管阻塞。
- Ki-67指数与T/NT%负相关、与FDG SUV比值正相关,T/NT%与SUV比值呈负相关。
- 边缘不规则、支气管阻塞、淋巴结及转移与较高Ki-67分级显著相关。
关键影像表现/征象
- 68例中44例(65%)病灶位于右肺。
- MDCT上44例(65%)为边界清楚的结节,24例(35%)为不规则肿块。
- 53例(78%)呈明显强化,20例(29%)见钙化,24例(35%)见支气管阻塞。
- 13例(19%)见淋巴结,15例(22%)见转移。
诊断标准与关键数值
- Ki-67指数与T/NT%呈负相关,与SUV比值呈正相关;T/NT%与SUV比值呈负相关。
- 边缘不规则和转移的存在与T/NT%呈负相关。
- 肿块、边缘不规则、支气管阻塞、淋巴结和转移的存在与较高SUV比值呈正相关。
- 边缘不规则、支气管阻塞、淋巴结和转移与较高Ki-67指数分级显著相关。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIMS: This study analyses the capability of contrast-enhanced multi-detector computed tomography (MDCT) and spectrum of molecular imaging to characterize typical carcinoids (TCs) of lung and their relationship with Ki-67 index.
MATERIALS AND METHODS: We analysed 68 patients with histological diagnosis of pulmonary TC, which underwent both MDCT and nuclear molecular imaging (somatostatin receptor scintigraphy/SPECT with 111In-pentetreotide and 18F-FDG-PET/CT) at staging evaluation before surgery. The MDCT scan was reviewed for the following features: size, margins, contrast enhancement, presence of calcifications, bronchial obstruction, lymph nodes and metastases. In 111In-pentetreotide SPECT, tumour/non-tumour ratio was measured at 4- and 24-h post-injection and the per cent difference was calculated (T/NT%). FDG uptake was measured as the ratio between lesion SUVmax and liver SUVmean (SUV ratio). All imaging features were correlated between them and with Ki-67 index.
RESULTS: Forty-four of the 68 lesions (65%) were in the right lung. In MDCT, scan lesions appeared as a well-defined nodule in 44 patients (65%) and irregular mass in 24 patients (35%). Contrast intense enhancement was present in 53 patients (78%), calcifications in 20 patients (29%) and bronchial obstruction in 24 patients (35%). Lymph nodes and metastasis were present in 13 (19%) and 15 (22%) patients. Ki-67 index was negatively correlated with T/NT% and positively with SUV ratio; T/NT% and SUV ratio were inversely correlated. The presence of irregular margins and metastases was negatively related to T/NT%. The presence of a mass, irregular margins, bronchial obstruction, lymph nodes and metastasis was positively related to higher SUV ratio. The presence of irregular margins, bronchial obstruction, lymph nodes and metastases was significantly correlated with a higher grade of Ki-67 index.
CONCLUSIONS: MDCT and nuclear molecular imaging are important to characterize lung TCs. The majority of TCs appear as a well-defined nodule generally not associated with extra-thorax signs. We found a significant correlation between some MDCT aspects, nuclear medicine features and Ki-67 index. The association of MDCT and nuclear medicine imaging may be useful in predicting proliferative activity and prognosis of lung TCs.
引用
- Danti G, Berti V, Abenavoli E, et al. Diagnostic imaging of typical lung carcinoids: relationship between MDCT, 111In-Octreoscan and 18F-FDG-PET imaging features with Ki-67 index. Radiol Med. 2020. PMID: 32189174. doi:10.1007/s11547-020-01172-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。