三维与四维剂量计算在乳腺调强放射治疗中的比较

Three-dimensional versus four-dimensional dose calculation for breast intensity-modulated radiation therapy.
PubMed 文献 · Br J Radiol · 2020-03-23

20例左侧乳腺癌患者接受自由呼吸下IMRT,基于3DCT制定计划(43.2 Gy/16次),并利用4DCT各时相模拟分次内和分次间运动计算四维累积剂量。四维计算剂量在适形性和均匀性上较原三维计划出现显著畸变,心脏、同侧肺及内乳淋巴结平均剂量均显著升高。作者结论认为自由呼吸左乳IMRT剂量计算时应优化内乳淋巴结剂量。

要点

  • 呼吸运动与多叶准直器调制的交互作用可导致剂量分布偏差,尤其影响内乳淋巴结区域。
  • 四维计算剂量较三维计划心脏平均剂量高0.34 Gy(p=0.010),同侧肺高0.59 Gy(p<0.001)。
  • 四维计算内乳淋巴结平均剂量较三维计划高1.42 Gy(p<0.001)。

关键影像表现/征象

  • 四维计算剂量较原三维计划在适形性和均匀性指数上出现显著畸变。
  • 四维计算剂量中心脏平均剂量较原三维计划高0.34 Gy(p=0.010)。
  • 四维计算剂量中同侧肺平均剂量较原三维计划高0.59 Gy(p<0.001)。
  • 四维计算剂量中内乳淋巴结平均剂量较原三维计划高1.42 Gy(p<0.001)。

临床应用与阅片要点

  • 作者认为自由呼吸左乳IMRT剂量计算时应优化内乳淋巴结剂量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To analyze the effect of intra- and interfractional motion during breast intensity modulated radiation therapy (IMRT) by calculating dose distribution based on four-dimensional computed tomography (4DCT).

METHODS: 20 patients diagnosed with left breast cancer were enrolled. Three-dimensional CT (3DCT) along with 10 phases of 4DCT were collected for each patient, with target volumes independently delineated on both 3DCT and all phases of 4DCT. IMRT plans were generated based on 3DCT (43.2 Gy in 16 fractions). The plan parameters for each segment were split into phases based on time duration estimates for each respiratory phase, with phase-specific dose distributions calculated and summated (4D-calculated dose). The procedure is repeated for 16 fractionations by randomly allocating starting phase using random-number generation to simulate interfractional discrepancy caused by different starting phase. Comparisons of plan quality between the original and 4D-calculated doses were analyzed.

RESULTS: There was a significant distortion in 4D-calculated dose induced by respiratory motion in terms of conformity and homogeneity index compared to those of the original 3D plan. Mean doses of the heart and the ipsilateral lung were significantly higher in the 4D-calculated doses compared to those of the original 3D plan (0.34 Gy, p = 0.010 and 0.59 Gy, p < 0.001), respectively). The mean internal mammary lymph node (IMN) dose was significantly greater in the 4D-calculated plan, compared to the original 3D plan (1.42 Gy, p < 0.001).

CONCLUSIONS: IMN doses should be optimized during the dose-calculation for the free-breathing left breast IMRT.

ADVANCES IN KNOWLEDGE: The interplay effect between respiratory motion and multileaf collimator modulation caused discrepancies in dose distribution, particularly in IMN.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Chung JH, Chun M, Kim JI, et al. Three-dimensional versus four-dimensional dose calculation for breast intensity-modulated radiation therapy. Br J Radiol. 2020. PMID: 32187503. doi:10.1259/bjr.20200047

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。