儿童电子烟或雾化产品使用相关肺损伤(EVALI)的胸部X线与CT表现
回顾性分析2018年12月至2019年12月一家三级儿童医院符合CDC EVALI标准且初诊时有胸片和CT的14例患儿(平均16岁),胸片和CT均以双肺对称性磨玻璃影为主,CT常见胸膜下豁免和反晕征,观察者间一致性近乎完美。
要点
- 儿童EVALI的胸片和CT以双肺对称性磨玻璃影为最常见表现,下叶受累为主。
- CT上胸膜下豁免见于79%(11/14),反晕征见于36%(5/14)。
- 两名儿科放射科医师对胸片和CT异常判读的一致性近乎完美(κ=0.99)。
关键影像表现/征象
- 胸片:磨玻璃影14/14(100%),实变8/14(57%)。
- CT:磨玻璃影14/14(100%),实变9/14(64%),小叶间隔增厚2/14(14%)。
- CT:胸膜下豁免11/14(79%),反晕征5/14(36%)。
- 胸片和CT异常均以双侧为主14/14(100%),对称13/14(93%),下叶为主7/14(50%)。
- 胸片和CT上病变范围均以弥漫为主。
诊断标准与关键数值
- 两名判读者对胸片异常的观察者间一致性κ=0.99(95%CI:0.97,1.00)。
- 两名判读者对CT异常的观察者间一致性κ=0.99(95%CI:0.98,1.00)。
临床应用与阅片要点
- 儿童EVALI的胸片和CT表现以双肺对称性磨玻璃影和实变为主,阅片时需注意下叶受累为主及CT上的胸膜下豁免和反晕征。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Electronic cigarette or vaping product use-associated lung injury (EVALI) is a serious public health concern with substantial morbidity and mortality, particularly in young individuals. Purpose To evaluate chest radiographic and chest CT findings of EVALI in the pediatric population. Materials and Methods This was a retrospective study of children who presented to a tertiary pediatric hospital from December 2018 to December 2019. Patients fulfilled the Centers for Disease Control and Prevention criteria for EVALI and had chest radiographs and CT images available at initial presentation. Two pediatric radiologists independently reviewed imaging for pattern, distribution, and extent of pulmonary abnormalities, as well as for extrapulmonary abnormalities. Clinical information, management, and outcomes were reviewed. Interobserver agreement was measured with Cohen κ coefficient. Results Seven male patients (50%) and seven female patients (50%) (mean age, 16 years; range, 13-18 years) were evaluated. All patients underwent chest radiography and CT within 4 days of presentation (range, 0-4 days). Chest radiographic findings included ground-glass opacity in 14 of 14 (100%) and consolidation in eight of 14 (57%). CT findings included ground-glass opacity in 14 of 14 (100%), consolidation in nine of 14 (64%), and interlobular septal thickening in two of 14 (14%). At CT, subpleural sparing was seen in 11 of 14 (79%) and a reversed halo sign was seen in five of 14 (36%). Chest radiographic and CT abnormalities were predominately bilateral in 14 of 14 (100%) and symmetric in 13 of 14 (93%), with lower lobe predominance in seven of 14 (50%). Extent of abnormality was predominately diffuse at both chest radiography and CT. There was almost perfect interobserver agreement between two reviewers for detecting abnormalities on chest radiographs (κ = 0.99; 95% confidence interval: 0.97, 1.00) and CT (κ = 0.99; 95% confidence interval: 0.98, 1.00). Conclusion In pediatric patients, electronic cigarette or vaping product use-associated lung injury is characterized by bilateral symmetric ground-glass opacities, consolidation, and a lower lobe predominance at CT. © RSNA, 2020.
引用
- Artunduaga M, Rao D, Friedman J, et al. Pediatric Chest Radiographic and CT Findings of Electronic Cigarette or Vaping Product Use-associated Lung Injury (EVALI). Radiology. 2020. PMID: 32125258. doi:10.1148/radiol.2020192778
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。