文献速递胸部CT

基于人工智能的全自动胸部CT肺气肿量化与肺功能检查的比较

Comparison of Artificial Intelligence-Based Fully Automatic Chest CT Emphysema Quantification to Pulmonary Function Testing.
PubMed 文献 · AJR Am J Roentgenol · 2020-03-04

回顾性纳入141例在6个月内完成胸部CT和肺功能检查的患者,评估基于人工智能的原型算法全自动量化肺气肿。两种重建方法的肺气肿百分比与Tiffeneau指数均呈很强负相关(ρ=-0.86和-0.85,均p<0.0001),提示AI量化能反映临床肺生理。

要点

  • AI全自动肺气肿量化与Tiffeneau指数呈很强负相关(ρ=-0.86和-0.85)。
  • 重建方法1肺气肿百分比均值9.96%±11.87%,方法2为8.04%±10.32%。
  • Tiffeneau指数<0.7视为气道阻塞,全部患者均值0.57±0.13。

核心结论

  • 基于人工智能的全自动肺气肿量化与Tiffeneau指数相关性良好,可能有助于基于影像的诊断和肺气肿严重程度量化。

研究设计与样本

  • 回顾性纳入141例同时接受胸部CT和肺功能检查(间隔6个月内)的患者,其中女性72例(平均年龄66.46±9.7岁,范围23-86岁),男性69例(平均年龄66.72±11.4岁,范围27-91岁)。
  • 采用基于深度卷积图像到图像网络的肺分割,该多层卷积神经网络结合多级特征链接和深度监控,训练中使用对抗网络区分网络输出与真实标注。
  • 肺气肿量化使用空间滤波和基于衰减的阈值,并与肺功能检查的Tiffeneau指数(第一秒用力呼气容积与用力肺活量之比)比较,采用Spearman相关系数。

诊断标准与关键数值

  • Tiffeneau指数<0.7视为气道阻塞。
  • 全部患者平均Tiffeneau指数为0.57±0.13。
  • 重建方法1的平均肺气肿百分比为9.96%±11.87%,重建方法2为8.04%±10.32%。
  • AI肺气肿量化与Tiffeneau指数的Spearman相关系数:重建方法1为ρ=-0.86,重建方法2为ρ=-0.85,均p<0.0001。

临床应用与阅片要点

  • AI全自动肺气肿量化与Tiffeneau指数呈很强负相关,可能有助于基于影像诊断和量化肺气肿严重程度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE. The purpose of this study was to evaluate an artificial intelligence (AI)-based prototype algorithm for fully automated quantification of emphysema on chest CT compared with pulmonary function testing (spirometry). MATERIALS AND METHODS. A total of 141 patients (72 women, mean age ± SD of 66.46 ± 9.7 years [range, 23-86 years]; 69 men, mean age of 66.72 ± 11.4 years [range, 27-91 years]) who underwent both chest CT acquisition and spirometry within 6 months were retrospectively included. The spirometry-based Tiffeneau index (TI; calculated as the ratio of forced expiratory volume in the first second to forced vital capacity) was used to measure emphysema severity; a value less than 0.7 was considered to indicate airway obstruction. Segmentation of the lung based on two different reconstruction methods was carried out by using a deep convolution image-to-image network. This multilayer convolutional neural network was combined with multilevel feature chaining and depth monitoring. To discriminate the output of the network from ground truth, an adversarial network was used during training. Emphysema was quantified using spatial filtering and attenuation-based thresholds. Emphysema quantification and TI were compared using the Spearman correlation coefficient. RESULTS. The mean TI for all patients was 0.57 ± 0.13. The mean percentages of emphysema using reconstruction methods 1 and 2 were 9.96% ± 11.87% and 8.04% ± 10.32%, respectively. AI-based emphysema quantification showed very strong correlation with TI (reconstruction method 1, ρ = -0.86; reconstruction method 2, ρ = -0.85; both p < 0.0001), indicating that AI-based emphysema quantification meaningfully reflects clinical pulmonary physiology. CONCLUSION. AI-based, fully automated emphysema quantification shows good correlation with TI, potentially contributing to an image-based diagnosis and quantification of emphysema severity.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Fischer AM, Varga-Szemes A, van Assen M, et al. Comparison of Artificial Intelligence-Based Fully Automatic Chest CT Emphysema Quantification to Pulmonary Function Testing. AJR Am J Roentgenol. 2020. PMID: 32130041. doi:10.2214/AJR.19.21572

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。