文献速递胸部CT

基于CT的影像组学与机器学习预测肺腺癌的气腔播散

CT-based radiomics and machine learning to predict spread through air space in lung adenocarcinoma.
PubMed 文献 · Eur Radiol · 2020-02-28

本研究回顾性纳入462例经病理确诊的肺腺癌患者,其中90例(19.5%)存在气腔播散(STAS)。研究基于术前薄层CT提取影像组学特征,采用随机森林(RF)构建预测模型,模型预测STAS的AUC为0.754,敏感度0.880、特异度0.588。结论认为基于CT的影像组学模型可在术前较好地预测肺腺癌的STAS。

要点

  • 随机森林模型预测STAS的AUC为0.754,敏感度0.880、特异度0.588。
  • 单因素分析显示12个影像组学特征及年龄与STAS显著相关。
  • 模型基于术前薄层CT影像组学特征构建,用于术前无创预测STAS。

核心结论

  • 基于CT的影像组学模型可在术前预测肺腺癌的STAS,诊断性能良好,RF模型AUC为0.754(敏感度0.880、特异度0.588)。

研究设计与样本

  • 回顾性研究,经机构审查委员会批准,纳入462例经病理确诊的肺腺癌患者(平均年龄58.06岁),其中90例(19.5%)存在STAS;由两名经验丰富的放射科医师在术前薄层CT图像上独立分割并提取影像组学特征,采用组内相关系数(ICC)和Pearson相关剔除低可靠性(ICC<0.75)和冗余(r>0.9)特征,单因素逻辑回归筛选与STAS相关的特征,采用随机森林(RF)构建模型并以五折交叉验证进行校准,以ROC曲线下面积(AUC)评估诊断性能。

诊断标准与关键数值

  • 单因素分析显示12个影像组学特征及年龄与STAS显著相关;RF模型预测STAS的AUC为0.754,敏感度0.880、特异度0.588。

临床应用与阅片要点

  • 作者认为基于CT的影像组学模型可在术前预测肺腺癌的STAS,诊断性能良好,可用于术前评估。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Spread through air space (STAS) is a novel invasive pattern of lung adenocarcinoma and is also a risk factor for recurrence and worse prognosis of lung adenocarcinoma. The aims of this study are to develop and validate a computed tomography (CT)‑based radiomics model for preoperative prediction of STAS in lung adenocarcinoma.

METHODS AND MATERIALS: This retrospective study was approved by an institutional review board and included 462 (mean age, 58.06 years) patients with pathologically confirmed lung adenocarcinoma. STAS was identified in 90 patients (19.5%). Two experienced radiologists segmented and extracted radiomics features on preoperative thin-slice CT images with radiomics extension independently. Intraclass correlation coefficients (ICC) and Pearson's correlation were used to rule out those low reliable (ICC < 0.75) and redundant (r > 0.9) features. Univariate logistic regression was applied to select radiomics features which were associated with STAS. A radiomics-based machine learning predictive model using a random forest (RF) was developed and calibrated with fivefold cross-validation. The diagnostic performance of the model was measured by the area under the curve (AUC) of receiver operating characteristic (ROC).

RESULTS: With univariate analysis, 12 radiomics features and age were found to be associated with STAS significantly. The RF model achieved an AUC of 0.754 (a sensitivity of 0.880 and a specificity of 0.588) for predicting STAS.

CONCLUSION: CT-based radiomics model can preoperatively predict STAS in lung adenocarcinoma with good diagnosis performance.

KEY POINTS: • CT-based radiomics and machine learning model can predict spread through air space (STAS) in lung adenocarcinoma with high accuracy. • The random forest (RF) model achieved an AUC of 0.754 (a sensitivity of 0.880 and a specificity of 0.588) for predicting STAS.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Jiang C, Luo Y, Yuan J, et al. CT-based radiomics and machine learning to predict spread through air space in lung adenocarcinoma. Eur Radiol. 2020. PMID: 32112116. doi:10.1007/s00330-020-06694-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。