文献速递胸部PETCT

18FDG PET/CT的SUVmax预测肺腺癌的组织学分级

SUVmax of 18FDG PET/CT Predicts Histological Grade of Lung Adenocarcinoma.
PubMed 文献 · Acad Radiol · 2020-02-26

该研究回顾性分析618例肺腺癌患者,评估术前18FDG PET/CT的SUVmax与组织学分级及病理亚型的关系,并用85例独立队列验证。结果显示SUVmax在低、中、高级别组间差异显著(p < .001),且随恶性程度升高而增高;鉴别低级别肿瘤的最佳SUVmax阈值为2.01(敏感度90.4%,特异度86.9%,AUC=0.928),鉴别高级别肿瘤的最佳阈值为7.41(敏感度79.8%,特异度73.5%,AUC=0.830)。结论认为SUVmax可用于预测肺腺癌的病理亚型和分级,18FDG PET-CT可作为无创工具辅助精准诊断及术前制定个体化治疗策略。

要点

  • SUVmax在低、中、高级别肺腺癌组间差异显著(p < .001),且随恶性程度升高而增高。
  • 鉴别低级别肿瘤的SUVmax最佳阈值为2.01(敏感度90.4%,特异度86.9%,AUC=0.928)。
  • 鉴别高级别肿瘤的SUVmax最佳阈值为7.41(敏感度79.8%,特异度73.5%,AUC=0.830)。

核心结论

  • SUVmax可用于预测肺腺癌的病理亚型和 histological grade。
  • 18FDG PET-CT可作为无创工具用于精准诊断,并有助于术前制定个体化治疗策略。

研究设计与样本

  • 回顾性分析618例肺腺癌患者的数据,评估术前18FDG-PET-CT测量的SUVmax与组织学分级及病理亚型的关系。
  • 使用Kruskal-Wallis检验比较组间差异,Bonferroni-Dunn检验进行组间两两比较,ROC分析确定鉴别不同组的最佳截断值。
  • 在85例连续肺腺癌病例的独立队列中验证截断值。

诊断标准与关键数值

  • 鉴别低级别肿瘤的最佳SUVmax截断值为2.01,敏感度90.4%,特异度86.9%,AUC=0.928(95%CI:0.91-0.95;p < .001)。
  • 鉴别高级别肿瘤的最佳SUVmax截断值为7.41,敏感度79.8%,特异度73.5%,AUC=0.830(95%CI:0.79-0.87;p < .001)。
  • 验证实验中,低级别组符合率为88.89%,中级别组为64.15%,高级别组为78.57%。

临床应用与阅片要点

  • 术前18FDG PET/CT测量的SUVmax可用于预测肺腺癌的组织学分级和病理亚型。
  • SUVmax随恶性程度增加而增高,低、中、高级别组间差异显著(p < .001)。
  • 鉴别低级别与高级别肿瘤可分别参考SUVmax阈值2.01和7.41。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The relationship between the 18FDG PET-CT maximum standard uptake value (SUVmax) and the type of lung adenocarcinoma is still not established. The aim of this study was to investigate the relationship between SUVmax value and histological grade and pathological subtype of lung adenocarcinoma, and to determine the optimum SUVmax cutoffs for distinguishing different histological grades.

MATERIALS AND METHODS: The data of 618 lung adenocarcinoma patients were retrospectively analyzed. The relationship between SUVmax measured on preoperative 18FDG-PET-CT and the histological grade and pathological subtype was examined. The Kruskal-Wallis test was used to compare differences among groups, and the Bonferroni-Dunn test for pairwise comparison among groups. ROC analysis was applied to determine the optimal cut-off values for distinguishing different groups. In addition, the cut-off value was verified in an independent cohort of 85 consecutive lung adenocarcinoma cases.

RESULTS: The SUVmax was significantly different between the low, intermediate, and high-grade groups(p < .001). SUVmax value increased with increase in the degree of malignancy. The optimal cut-off value for identifying low-grade tumors was 2.01 (sensitivity 90.4%, specificity 86.9%, area under the curve [AUC] = 0.928, 95% confidence interval: 0.91-0.95; p < .001). The optimal cutoff SUVmax value for identifying high-grade tumors was 7.41 (sensitivity 79.8%, specificity 73.5%, AUC = 0.830, 95% confidence interval: 0.79-0.87; p < .001). The validation experiment showed that the coincidence rate was 88.89% in the low-level group, 64.15% in the middle-level group, and 78.57% in the high-level group.

CONCLUSION: SUVmax can be used to predict pathological subtype and histological grade of lung adenocarcinoma. Thus, 18FDG PET-CT can serve as a noninvasive tool for precise diagnosis and help in the preoperative formulation of patient-specific treatment strategies.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Sun XY, Chen TX, Chang C, et al. SUVmax of 18FDG PET/CT Predicts Histological Grade of Lung Adenocarcinoma. Acad Radiol. 2020. PMID: 32113879. doi:10.1016/j.acra.2020.01.030

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。