低剂量胸部CT对染色体DNA的生物学效应

Biological Effects of Low-Dose Chest CT on Chromosomal DNA.
PubMed 文献 · Radiology · 2020-03-10

该前瞻性研究于2016年3月至2018年6月纳入209例转诊行胸部CT的参与者,比较低剂量与标准剂量CT对外周血淋巴细胞DNA双链断裂和染色体畸变的影响。低剂量CT(中位有效剂量1.5 mSv)前后DNA双链断裂和染色体畸变数量无差异,而标准剂量CT(中位有效剂量5.0 mSv)后两者均增加。结论为未检测到低剂量CT对人DNA的效应。

要点

  • 低剂量胸部CT(中位有效剂量1.5 mSv)前后γ-H2AX焦点和染色体畸变数量无差异。
  • 标准剂量胸部CT(中位有效剂量5.0 mSv)后DNA双链断裂和染色体畸变增加。
  • 低剂量CT未检测到对人DNA的效应,标准剂量CT在同一条件下显示DNA损伤增加。

诊断标准与关键数值

  • 低剂量胸部CT中位有效剂量1.5 mSv,标准剂量胸部CT中位有效剂量5.0 mSv。
  • 标准剂量CT后γ-H2AX焦点数增加(P < .001),染色体畸变增加(P = .003)。
  • 低剂量CT前后γ-H2AX焦点数无差异(P = .45),染色体畸变无差异(P = .69)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Although the National Lung Screening Trial reported a significant reduction in lung cancer mortality when low-dose (LD) CT chest examinations are used for a diagnosis, their biologic effects from radiation exposure remain unclear. Purpose To compare LD CT and standard-dose (SD) CT for DNA double-strand breaks and chromosome aberrations (CAs) in peripheral blood lymphocytes. Materials and Methods Between March 2016 and June 2018, 209 participants who were referred to a respiratory surgery department for chest CT studies were prospectively enrolled in this study. Individuals were excluded if they had undergone radiography examinations within the last 3 days or had undergone chemotherapy or radiation therapy. Peripheral blood samples were obtained before and 15 minutes after CT. The number of γ-H2AX foci and unstable CAs in lymphocytes was quantified by immunofluorescent staining of γ-H2AX and by fluorescence in situ hybridization by using peptide nucleic acid probes for centromeres and telomeres, respectively. The Wilcoxon signed rank test was used for statistical analysis. Bonferroni correction was applied for multiple comparisons. Results Of the 209 participants (105 women, 104 men; mean age, 67.0 years ± 11.3 [standard deviation]), 107 underwent chest LD CT and 102 underwent chest SD CT. Sex distribution, age, and body size metrics were similar between the two groups. The median effective dose of LD CT and SD CT was 1.5 and 5.0 mSv, respectively. The number of double-strand breaks and CAs increased after a SD CT examination (γ-H2AX, P < .001; CAs, P = .003); the number of double-strand breaks and CAs before and after LD CT was not different (γ-H2AX, P = .45; CAs, P = .69). Conclusion No effect of low-dose CT on human DNA was detected. In the same setting, DNA double-strand breaks and chromosome aberrations increased after standard-dose CT. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Brenner in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Sakane H, Ishida M, Shi L, et al. Biological Effects of Low-Dose Chest CT on Chromosomal DNA. Radiology. 2020. PMID: 32154776. doi:10.1148/radiol.2020190389

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。