癌症早期检测:疑似鼻咽癌患者MR成像分级系统的评估
本研究在鼻咽癌流行区回顾性分析383例疑似无鼻咽癌患者与383例鼻咽癌患者的鼻咽部MR图像,比较现行、改良及平扫三种分级系统。改良系统与平扫系统优化了原发灶标准并增加淋巴结评估,分级由4级扩展为5级;改良系统综合性能显著优于现行系统与平扫系统。平扫低级别者增强后未检出额外癌症,平扫在筛查中具潜在价值。
要点
- 改良MR分级系统将分级由4级扩展为5级,综合诊断性能显著优于现行系统与平扫系统。
- 平扫分级1-2级的病例增强后未检出额外癌症,提示低级别者增强价值有限。
- 平扫系统敏感度97.65%、特异度86.42%,作者认为其可用于筛查项目。
关键影像表现/征象
- 改良系统与平扫系统均细化了原发肿瘤标准,并增加了淋巴结评估。
- 改良系统与平扫系统中,鼻咽癌患者位于1-2级的比例分别为0.42%与0.44%,位于3级的比例分别为6.31%与6.96%,位于4-5级的比例分别为90.36%与87.79%。
- 平扫分级为1-2级的病例,增强后未检出额外癌症。
诊断标准与关键数值
- 现行系统敏感度99.74%、特异度63.45%。
- 改良系统敏感度97.91%、特异度89.56%。
- 平扫系统敏感度97.65%、特异度86.42%。
- 改良系统综合性能显著优于现行系统(χ²=122)与平扫系统(χ²=6.1),χ²值大于5.99提示差异有统计学意义。
临床应用与阅片要点
- 作者提出改良MR成像分级系统用于鼻咽癌检测,并认为造影剂对低MR分级无价值。
- 作者认为平扫在筛查项目中显示出潜在用途。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: We evaluated modifications to our contrast-enhanced MR imaging grading system for symptomatic patients with suspected nasopharyngeal carcinoma, aimed at improving discrimination of early-stage cancer and benign hyperplasia. We evaluated a second non-contrast-enhanced MR imaging grading system for asymptomatic patients from nasopharyngeal carcinoma plasma screening programs.
MATERIALS AND METHODS: Dedicated nasopharyngeal MR imaging before (plain scan system) and after intravenous contrast administration (current and modified systems) was reviewed in patients from a nasopharyngeal carcinoma-endemic region, comprising 383 patients with suspected disease without nasopharyngeal carcinoma and 383 patients with nasopharyngeal carcinoma. The modified and plain scan systems refined primary tumor criteria, added a nodal assessment, and expanded the system from 4 to 5 grades. The overall combined sensitivity and specificity of the 3 systems were compared using the extended McNemar test (a χ2 value [Formula: see text]> 5.99 indicates significance).
RESULTS: The current, modified, and plain scan MR imaging systems yielded sensitivities of 99.74%, 97.91%, and 97.65%, respectively, and specificities of 63.45%, 89.56% and 86.42%, respectively. The modified system yielded significantly better performance than the current ([Formula: see text] = 122) and plain scan ([Formula: see text] = 6.1) systems. The percentages of patients with nasopharyngeal carcinoma in grades 1-2, grade 3, and grades 4-5 for the modified and plain scan MR imaging systems were 0.42% and 0.44%; 6.31% and 6.96%; and 90.36% and 87.79%, respectively. No additional cancers were detected after contrast administration in cases of a plain scan graded 1-2.
CONCLUSIONS: We propose a modified MR imaging grading system that improves diagnostic performance for nasopharyngeal carcinoma detection. Contrast was not valuable for low MR imaging grades, and the plain scan shows potential for use in screening programs.
引用
- King AD, Woo JKS, Ai QY, et al. Early Detection of Cancer: Evaluation of MR Imaging Grading Systems in Patients with Suspected Nasopharyngeal Carcinoma. AJNR Am J Neuroradiol. 2020. PMID: 32184223. doi:10.3174/ajnr.A6444
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。