TOF-MRA上的血流分数作为儿童颅内动脉狭窄卒中风险的测量指标
回顾性研究评估41例颅内动脉狭窄患儿TOF-MRA信号强度比值与常规血管造影狭窄程度及梗死风险的关系。信号强度比值与狭窄程度呈中度负相关(R=-0.54,P<.001),以比值>1.00判断重度(≥70%)狭窄的AUC为0.86,敏感度97.1%、特异度77.8%。伴有下游梗死的动脉信号强度比值低于无梗死动脉(0.81±0.52 vs 1.31±0.55,P<.001)。
要点
- TOF-MRA信号强度比值(狭窄后/狭窄前)与常规血管造影狭窄程度呈中度负相关(R=-0.54,P<.001)。
- 以信号强度比值>1.00判断重度(≥70%)狭窄的AUC为0.86,敏感度97.1%、特异度77.8%。
- 伴有下游梗死的动脉信号强度比值低于无梗死动脉(0.81±0.52 vs 1.31±0.55,P<.001)。
关键影像表现/征象
- 狭窄节段最常见位于大脑中动脉近端(22/70,31%)。
- 信号强度比值随狭窄等级增加而降低(无/轻-中/重/完全闭塞,P<.001)。
诊断标准与关键数值
- 信号强度比值与常规血管造影狭窄程度呈中度负相关(R=-0.54,P<.001)。
- 以信号强度比值>1.00判断重度(≥70%)颈动脉狭窄的AUC为0.86。
- MRA判断重度狭窄的敏感度42.8%、特异度58.8%、阳性预测值30.0%、阴性预测值71.4%。
- 信号强度比值>1.00判断重度狭窄的敏感度97.1%、特异度77.8%、阳性预测值71.7%、阴性预测值97.4%。
- MRA联合信号强度比值判断重度狭窄的敏感度75.5%、特异度100%、阳性预测值100%、阴性预测值76.8%。
临床应用与阅片要点
- 在儿童颅内动脉狭窄评估中,可计算TOF-MRA狭窄后/狭窄前信号强度比值,以比值>1.00作为提示重度(≥70%)狭窄的阈值。
- 信号强度比值降低与下游梗死相关(0.81±0.52 vs 1.31±0.55,P<.001),阅片时可结合比值变化提示高风险病变。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: Conventional angiography is the criterion standard for measuring intracranial arterial stenosis. We evaluated signal intensity ratios from TOF-MRA as a measure of intracranial stenosis and infarct risk in pediatric stroke.
MATERIALS AND METHODS: A retrospective study was undertaken in children with intracranial arterial stenosis, who had TOF-MRA and conventional angiography performed within 6 months. Arterial diameters were measured for percentage stenosis. ROI analysis on TOF-MRA measured signal intensity in pre- and poststenotic segments, with post-/pre-signal intensity ratios calculated. The Pearson correlation was used to compare percentage stenosis on MRA with conventional angiography and signal intensity ratios with percentage stenosis; the point-biserial correlation was used for infarcts compared with percentage stenosis and signal intensity ratios. Sensitivity, specificity, and positive and negative predictive values were calculated for determining severe (≥70%) stenosis from MRA and signal intensity ratios against the criterion standard conventional angiography. P < .05 was considered statistically significant.
RESULTS: Seventy stenotic segments were found in 48 studies in 41 children (median age, 11.0 years; range, 5 months to 17.0 years; male/female ratio, 22:19): 20/41 (48.8%) bilateral, 11/41 (26.8%) right, and 10/41 (24.4%) left, with the most common site being the proximal middle cerebral artery (22/70, 31%). Moyamoya disease accounted for 27/41 (65.9%). Signal intensity ratios and conventional angiography stenosis showed a moderate negative correlation (R = -0.54, P < .001). Receiver operating characteristic statistics showed an area under the curve of 0.86 for using post-/pre-signal intensity ratios to determine severe (≥70%) carotid stenosis, yielding a threshold of 1.00. Sensitivity, specificity, and positive and negative predictive values for severe stenosis were the following-MRA: 42.8%, 58.8%, 30.0%, and 71.4%; signal intensity ratio >1.00: 97.1%, 77.8%, 71.7%, and 97.4%; combination: 75.5%, 100%, 100%, and 76.8%, respectively. Signal intensity ratios decreased with increasing grade of stenosis (none/mild-moderate/severe/complete, P < .001) and were less when associated with infarcts (0.81 ± 0.52 for arteries associated with downstream infarcts versus 1.31 ± 0.55 for arteries without associated infarcts, P < .001).
CONCLUSIONS: Signal intensity ratios from TOF-MRA can serve as a noninvasive measure of intracranial arterial stenosis and allow identification of high-risk lesions in pediatric stroke.