文献速递神经MR

归一化弥散与ASL灌注比值检测缺氧性脑损伤:对血脑屏障损伤与通透性的意义

Anoxic Brain Injury Detection with the Normalized Diffusion to ASL Perfusion Ratio: Implications for Blood-Brain Barrier Injury and Permeability.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-03-12

研究纳入2002至2019年35例缺氧性脑损伤患者与34例健康对照,在ASL与DWI坐标匹配ROI上分析灌注与弥散信号关系并生成归一化弥散/灌注比值图。ASL与DWI信号呈显著正相关,联合斜率>0且R²>0.78的截断值诊断敏感度0.86、特异度0.82;健康对照全脑比值异质,患者呈均匀比值。

要点

  • 缺氧性脑损伤中ASL灌注信号与DWI弥散信号呈均匀的正相关,弥散信号增高区ASL信号亦增高。
  • 以斜率>0且R²>0.78为联合截断值,鉴别缺氧性脑损伤的敏感度0.86、特异度0.82。
  • 归一化弥散/灌注比值彩色图在健康对照呈异质、在患者呈均匀,可能作为诊断影像生物标志物。

核心结论

  • 缺氧性脑损伤中定性灌注与DWI信号呈均匀正相关,即弥散信号增高区ASL信号也增高。
  • 利用该关系的归一化弥散/灌注比值彩色图可能成为诊断缺氧性脑损伤并潜在评估血脑屏障完整性的影像生物标志物。

研究设计与样本

  • 研究纳入2002至2019年诊断的缺氧性脑损伤患者35例与健康对照34例。
  • 在ASL上绘制12个ROI,并在DWI上识别坐标匹配的ROI,行线性回归分析ASL灌注与弥散信号的关系。
  • 使用自建算法生成归一化弥散/灌注图。

关键影像表现/征象

  • 归一化弥散/灌注比值彩色图在健康对照显示全脑异质性比值,在缺氧性脑损伤患者显示均匀比值。
  • 线性回归分析显示ASL与DWI信号呈显著正相关。

诊断标准与关键数值

  • 以斜率>0且R²>0.78为联合截断值,线性回归鉴别缺氧性脑损伤的敏感度为0.86(95% CI,0.71-0.94)、特异度为0.82(95% CI,0.66-0.92)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Anoxic brain injury is a result of prolonged hypoxia. We sought to describe the nonquantitative arterial spin-labeling perfusion imaging patterns of anoxic brain injury, characterize the relationship of arterial spin-labeling and DWI, and evaluate the normalized diffusion-to-perfusion ratio to differentiate patients with anoxic brain injury from healthy controls.

MATERIALS AND METHODS: We identified all patients diagnosed with anoxic brain injuries from 2002 to 2019. Twelve ROIs were drawn on arterial spin-labeling with coordinate-matched ROIs identified on DWI. Linear regression analysis was performed to examine the relationship between arterial spin-labeling perfusion and diffusion signal. Normalized diffusion-to-perfusion maps were generated using a custom-built algorithm.

RESULTS: Thirty-five patients with anoxic brain injuries and 34 healthy controls were identified. Linear regression analysis demonstrated a significant positive correlation between arterial spin-labeling and DWI signal. By means of a combinatory cutoff of slope of >0 and R2 of > 0.78, linear regression using arterial spin-labeling and DWI showed a sensitivity of 0.86 (95% CI, 0.71-0.94) and specificity of 0.82 (95% CI, 0.66-0.92) for anoxic brain injuries. A normalized diffusion-to-perfusion color map demonstrated heterogeneous ratios throughout the brain in healthy controls and homogeneous ratios in patients with anoxic brain injuries.

CONCLUSIONS: In anoxic brain injuries, a homogeneously positive correlation between qualitative perfusion and DWI signal was identified so that areas of increased diffusion signal showed increased ASL signal. By exploiting this relationship, the normalized diffusion-to-perfusion ratio color map may be a valuable imaging biomarker for diagnosing anoxic brain injury and potentially assessing BBB integrity.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Li N, Wingfield MA, Nickerson JP, et al. Anoxic Brain Injury Detection with the Normalized Diffusion to ASL Perfusion Ratio: Implications for Blood-Brain Barrier Injury and Permeability. AJNR Am J Neuroradiol. 2020. PMID: 32165356. doi:10.3174/ajnr.A6461

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。