文献速递神经介入MR

基于深度学习单次检测器的T1加权MRI脑转移瘤计算机辅助检测用于立体定向放射外科

Computer-aided Detection of Brain Metastases in T1-weighted MRI for Stereotactic Radiosurgery Using Deep Learning Single-Shot Detectors.
PubMed 文献 · Radiology · 2020-03-17

本回顾性研究分析了2011年1月至2018年8月接受伽玛刀立体定向放射外科治疗患者的对比增强三维T1加权梯度回波MRI,构建并训练深度学习单次检测器(SSD)算法以检测脑转移瘤。在测试组中,最高性能(基线)SSD在50%置信度阈值下敏感度为81%(95%CI:80%,82%;190/234),阳性预测值为36%(95%CI:35%,37%;190/530);对于直径至少6 mm的转移瘤,敏感度为98%(95%CI:97%,99%;130/132),阳性预测值为36%(95%CI:35%,37%;130/366)。结论认为深度学习SSD模型使用对比增强T1加权MRI可检测几乎全部6 mm及以上的脑转移瘤,假阳性结果有限。

要点

  • 基线SSD对≥6 mm脑转移瘤敏感度98%(130/132),对全部转移瘤敏感度81%(190/234)。
  • 基线SSD阳性预测值36%,全部转移瘤检出190/530,≥6 mm检出130/366。
  • 其他模型(ResNet50骨干SSD、焦点损失SSD、RetinaNet)敏感度73%–79%,阳性预测值13%–29%,均低于基线SSD。

诊断标准与关键数值

  • 在50%置信度阈值下,测试组最高性能(基线)SSD的基于病灶的敏感度为81%(95%CI:80%,82%;190/234),阳性预测值为36%(95%CI:35%,37%;190/530)。
  • 对于直径至少6 mm的转移瘤,基线SSD敏感度为98%(95%CI:97%,99%;130/132),阳性预测值为36%(95%CI:35%,37%;130/366)。
  • ResNet50骨干SSD敏感度为73%(95%CI:72%,74%;171/234),阳性预测值为29%(95%CI:28%,30%;171/581)。
  • 焦点损失SSD敏感度为77%(95%CI:76%,78%;180/234),阳性预测值为26%(95%CI:26%,26%;180/681)。
  • RetinaNet敏感度为79%(95%CI:77%,81%;184/234),阳性预测值为13%(95%CI:12%,14%;184/1412)。

临床应用与阅片要点

  • 基线SSD在50%置信度阈值下对≥6 mm脑转移瘤敏感度达98%,可用于辅助立体定向放射外科治疗计划中的病灶检出。
  • 基线SSD阳性预测值为36%,需注意假阳性发现;其他模型敏感度和阳性预测值均低于基线SSD。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Brain metastases are manually identified during stereotactic radiosurgery (SRS) treatment planning, which is time consuming and potentially challenging. Purpose To develop and investigate deep learning (DL) methods for detecting brain metastasis with MRI to aid in treatment planning for SRS. Materials and Methods In this retrospective study, contrast material-enhanced three-dimensional T1-weighted gradient-echo MRI scans from patients who underwent gamma knife SRS from January 2011 to August 2018 were analyzed. Brain metastases were manually identified and contoured by neuroradiologists and treating radiation oncologists. DL single-shot detector (SSD) algorithms were constructed and trained to map axial MRI slices to a set of bounding box predictions encompassing metastases and associated detection confidences. Performances of different DL SSDs were compared for per-lesion metastasis-based detection sensitivity and positive predictive value (PPV) at a 50% confidence threshold. For the highest-performing model, detection performance was analyzed by using free-response receiver operating characteristic analysis. Results Two hundred sixty-six patients (mean age, 60 years ± 14 [standard deviation]; 148 women) were randomly split into 80% training and 20% testing groups (212 and 54 patients, respectively). For the testing group, sensitivity of the highest-performing (baseline) SSD was 81% (95% confidence interval [CI]: 80%, 82%; 190 of 234) and PPV was 36% (95% CI: 35%, 37%; 190 of 530). For metastases measuring at least 6 mm, sensitivity was 98% (95% CI: 97%, 99%; 130 of 132) and PPV was 36% (95% CI: 35%, 37%; 130 of 366). Other models (SSD with a ResNet50 backbone, SSD with focal loss, and RetinaNet) yielded lower sensitivities of 73% (95% CI: 72%, 74%; 171 of 234), 77% (95% CI: 76%, 78%; 180 of 234), and 79% (95% CI: 77%, 81%; 184 of 234), respectively, and lower PPVs of 29% (95% CI: 28%, 30%; 171 of 581), 26% (95% CI: 26%, 26%; 180 of 681), and 13% (95% CI: 12%, 14%; 184 of 1412). Conclusion Deep-learning single-shot detector models detected nearly all brain metastases that were 6 mm or larger with limited false-positive findings using postcontrast T1-weighted MRI. © RSNA, 2020 See also the editorial by Kikinis and Wells in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Zhou Z, Sanders JW, Johnson JM, et al. Computer-aided Detection of Brain Metastases in T1-weighted MRI for Stereotactic Radiosurgery Using Deep Learning Single-Shot Detectors. Radiology. 2020. PMID: 32181729. doi:10.1148/radiol.2020191479

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。