儿童PET/MRI中腺样体和腭扁桃体的正常FDG摄取
本研究回顾性分析41例儿童脑部FDG PET/MRI,报告正常腺样体和腭扁桃体的SUV范围及左右不对称性。右侧扁桃体平均SUV为5.30±1.57,左侧为5.25±1.53,腺样体为4.56±1.90;左右扁桃体SUV差异无统计学意义(P=0.69)。腺样体与扁桃体FDG摄取呈中度正相关(r=0.36-0.41)。
要点
- 左右扁桃体FDG摄取差异无统计学意义,阅片时不应仅凭轻度不对称判断为异常。
- 腺样体与扁桃体FDG摄取呈中度正相关,一侧高摄取可能提示另一侧也存在生理性高摄取。
关键影像表现/征象
- 右侧扁桃体平均SUV为5.30±1.57,左侧为5.25±1.53,腺样体为4.56±1.90。
- 右侧扁桃体最大SUV为8.47±2.22,左侧为8.45±2.18,腺样体为7.59±2.94。
- 左右扁桃体平均SUV差异无统计学意义(P=0.69),最大SUV差异无统计学意义(P=0.90)。
- 腺样体与左右扁桃体FDG摄取在平均和最大SUV上均呈中度正相关(r=0.36-0.41;P=0.008-0.022)。
诊断标准与关键数值
- 正常儿童腭扁桃体平均SUV范围宽,右侧5.30±1.57、左侧5.25±1.53;最大SUV右侧8.47±2.22、左侧8.45±2.18。
- 正常儿童腺样体平均SUV为4.56±1.90,最大SUV为7.59±2.94。
- 左右扁桃体SUV比值及腺样体/扁桃体SUV比值被计算,但原文未报告具体数值。
临床应用与阅片要点
- 阅片时应注意儿童正常扁桃体和腺样体FDG摄取可呈较高水平且变异较大,避免误判为病变。
- 左右扁桃体SUV差异无统计学意义,轻度不对称可能为生理性,不应仅据此诊断异常。
- 腺样体与扁桃体FDG摄取存在中度正相关,评估一侧高摄取时可参考另一侧。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: Information about the normal [F-18]2-fluoro-2-deoxyglucose (FDG) uptake in the adenoids and palatine tonsils in children is not available.
OBJECTIVE: The purpose of this study was to report the range of standardized uptake values (SUVs) in the normal adenoids and palatine tonsils in children, assess for the degree of asymmetry between the right and left tonsils and evaluate for the correlation of SUVs between the adenoids and tonsils.
MATERIALS AND METHODS: Pediatric patients who had had an FDG positron emission tomography (PET)/magnetic resonance imaging (MRI) brain study in our institution from January 2018 to March 2019 were identified. Patients with a history of malignancy, adenoidectomy and/or tonsillectomy, incomplete imaging coverage of Waldeyer ring and the presence of artifact on PET/MRI were excluded. Two pediatric radiologists independently measured the mean and maximum SUVs of the right tonsil, left tonsil and the adenoids. Range, mean and standard deviation were calculated for all measurements. Ratios of SUV of the left to right tonsils and the adenoids to the tonsils were calculated. The paired t-test and Pearson's correlation test were used for statistical analysis with a P-value <0.05 considered to be significant.
RESULTS: Sixty-one PET/MRI brain scans were performed in our institution during the study period. After reviewing for exclusion criteria, 41 patients were included in the study (mean age: 10.1 years, range: 2-17 years; 19 boys and 22 girls). The mean SUV was 5.30±1.57 in the right tonsil, 5.25±1.53 in the left tonsil and 4.56±1.90 in the adenoids. The maximum SUV was 8.47±2.22 in the right tonsil, 8.45±2.18 in the left tonsil and 7.59±2.94 in the adenoids. The difference between the SUVs of the right and left tonsil was not statistically significant (P=0.69 for mean SUV and P=0.90 for maximum SUV). There was a statistically significant moderately positive correlation between the FDG uptake in the adenoids and the right and left tonsil for both mean and maximum SUV (r=0.36-0.41; P=0.008-0.022).
CONCLUSION: There is a wide variation of FDG uptake in the normal tonsils and adenoids in children. Uptake in the right and left tonsils is not significantly different. There is a moderately positive correlation between the FDG uptake in the adenoids and the tonsils.
引用
- Kumbhar SS, Qi J. Normal FDG uptake in the adenoids and palatine tonsils in children on PET/MRI. Pediatr Radiol. 2020. PMID: 32198664. doi:10.1007/s00247-020-04650-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。