文献速递神经MR

胶质母细胞瘤与孤立性脑转移瘤的鉴别:基于流入的血管空间占用与动态磁敏感对比MR成像的比较

Discrimination between Glioblastoma and Solitary Brain Metastasis: Comparison of Inflow-Based Vascular-Space-Occupancy and Dynamic Susceptibility Contrast MR Imaging.
PubMed 文献 · AJNR Am J Neuroradiol · 2020-03-05

本研究纳入20例胶质母细胞瘤和22例孤立性脑转移瘤患者,在3T临床扫描仪上比较基于流入的血管空间占用(无需外源性对比剂)与DSC MR成像的鉴别价值。结果显示,肿瘤内区基于流入的血管空间占用参数在胶质母细胞瘤中显著更高(AUC 0.91和0.90),而肿瘤内DSC-相对CBV无显著差异(P = .616);瘤周T2高信号区DSC-相对CBV的AUC最高(0.94)。结论认为基于流入的血管空间占用有潜力鉴别两者,尤其在肿瘤内区。

要点

  • 肿瘤内区基于流入的血管空间占用动脉血CBV及相对动脉血CBV在胶质母细胞瘤中显著高于孤立性脑转移瘤(均P < .001),AUC分别为0.91和0.90。
  • 瘤周T2高信号区DSC-相对CBV鉴别胶质母细胞瘤与孤立性脑转移瘤的AUC最高(0.94),基于流入的血管空间占用动脉血CBV和相对动脉血CBV的AUC分别为0.83和0.72。
  • 肿瘤内区DSC-相对CBV在两组间无显著差异(P = .616),不宜单独用于肿瘤内区鉴别。

关键影像表现/征象

  • 瘤周T2高信号区:胶质母细胞瘤的DSC-相对CBV(P < .001)、基于流入的血管空间占用动脉血CBV(P = .001)和相对动脉血CBV(P = .005)均显著高于孤立性脑转移瘤。
  • 肿瘤内区:胶质母细胞瘤的基于流入的血管空间占用动脉血CBV和相对动脉血CBV均显著高于孤立性脑转移瘤(均P < .001)。
  • 肿瘤内区DSC-相对CBV在两组间无显著差异(P = .616)。

诊断标准与关键数值

  • 瘤周T2高信号区鉴别胶质母细胞瘤与孤立性脑转移瘤的AUC:DSC-相对CBV为0.94,基于流入的血管空间占用动脉血CBV为0.83,相对动脉血CBV为0.72。
  • 肿瘤内区鉴别胶质母细胞瘤与孤立性脑转移瘤的AUC:基于流入的血管空间占用动脉血CBV为0.91,相对动脉血CBV为0.90。
  • 所有参数在肿瘤内区和瘤周T2高信号区的观察者间信度良好或优秀(ICC 0.74~0.89)。

临床应用与阅片要点

  • 基于流入的血管空间占用无需外源性对比剂,可在肿瘤内区测量动脉血CBV及相对动脉血CBV以辅助鉴别胶质母细胞瘤与孤立性脑转移瘤。
  • 肿瘤内区DSC-相对CBV在两组间无显著差异(P = .616),单独用于肿瘤内区鉴别时价值有限。
  • 瘤周T2高信号区DSC-相对CBV的鉴别AUC最高(0.94),但需使用外源性对比剂。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Accurate differentiation between glioblastoma and solitary brain metastasis is of vital importance clinically. This study aimed to investigate the potential value of the inflow-based vascular-space-occupancy MR imaging technique, which has no need for an exogenous contrast agent, in differentiating glioblastoma and solitary brain metastasis and to compare it with DSC MR imaging.

MATERIALS AND METHODS: Twenty patients with glioblastoma and 22 patients with solitary brain metastasis underwent inflow-based vascular-space-occupancy and DSC MR imaging with a 3T clinical scanner. Two neuroradiologists independently measured the maximum inflow-based vascular-space-occupancy-derived arteriolar CBV and DSC-derived CBV values in intratumoral regions and peritumoral T2-hyperintense regions, which were normalized to the contralateral white matter (relative arteriolar CBV and relative CBV, inflow-based vascular-space-occupancy relative arteriolar CBV, and DSC-relative CBV). The intraclass correlation coefficient, Student t test, or Mann-Whitney U test and receiver operating characteristic analysis were performed.

RESULTS: All parameters of both regions had good or excellent interobserver reliability (0.74∼0.89). In peritumoral T2-hyperintese regions, DSC-relative CBV (P < .001), inflow-based vascular-space-occupancy arteriolar CBV (P = .001), and relative arteriolar CBV (P = .005) were significantly higher in glioblastoma than in solitary brain metastasis, with areas under the curve of 0.94, 0.83, and 0.72 for discrimination, respectively. In the intratumoral region, both inflow-based vascular-space-occupancy arteriolar CBV and relative arteriolar CBV were significantly higher in glioblastoma than in solitary brain metastasis (both P < .001), with areas under the curve of 0.91 and 0.90, respectively. Intratumoral DSC-relative CBV showed no significant difference (P = .616) between the 2 groups.

CONCLUSIONS: Inflow-based vascular-space-occupancy has the potential to discriminate glioblastoma from solitary brain metastasis, especially in the intratumoral region.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Li X, Wang D, Liao S, et al. Discrimination between Glioblastoma and Solitary Brain Metastasis: Comparison of Inflow-Based Vascular-Space-Occupancy and Dynamic Susceptibility Contrast MR Imaging. AJNR Am J Neuroradiol. 2020. PMID: 32139428. doi:10.3174/ajnr.A6466

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。