术中双期锥形束CT在肝硬化患者TACE术中检测和表征肝细胞癌的诊断准确性优于术前MRI和多层螺旋CT
单中心回顾性观察研究纳入72例拟行TACE的肝硬化患者,比较术中双期锥形束CT与术前多层螺旋CT或MRI检测和表征肝细胞癌的诊断准确性,以随访LI-RADS影像行为为参考标准。双期锥形束CT的敏感度99%、特异度89%、阴性预测值92%、准确性94%,均优于术前影像(分别为78%、85%、30%、79%);双期锥形束CT还检出63个隐匿性富血供病灶,其中54个为隐匿性肝细胞癌。
要点
- 术中双期CBCT检测富血供病灶的敏感度99%、阴性预测值92%,均高于术前多层螺旋CT或MRI的78%和30%。
- 双期CBCT检出63个隐匿性富血供病灶,其中54个为隐匿性肝细胞癌,占全部病灶的22.2%。
- 双期CBCT测得的肿瘤平均直径较术前多层螺旋CT或MRI高7.5%(95%CI 3.7-11.3,p<0.05)。
关键影像表现/征象
- 双期锥形束CT检出63个隐匿性富血供病灶,其中54个为隐匿性肝细胞癌,6个为隐匿性血管瘤,3个为假阳性。
- 双期锥形束CT测得的肿瘤平均直径较术前第二线影像高7.5%(95%CI 3.7-11.3,p<0.05)。
诊断标准与关键数值
- 双期锥形束CT检测富血供病灶的敏感度99%、特异度89%、阳性预测值99%、阴性预测值92%、准确性94%。
- 术前第二线影像(多层螺旋CT或MRI)检测富血供病灶的敏感度78%、特异度85%、阳性预测值99%、阴性预测值30%、准确性79%。
- 参考标准为随访期间富血供病灶按LI-RADS标准的影像行为。
临床应用与阅片要点
- 阅片和报告时可关注双期锥形束CT上仅显示的隐匿性富血供病灶,本研究中有54例为隐匿性肝细胞癌。
- 双期锥形束CT测得的肿瘤直径较术前影像高7.5%,报告肿瘤大小时需注意检查方式间的差异。
局限性
- 本研究为单中心、回顾性、观察性研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study was directed to compare diagnostic accuracy of dual-phase cone beam computed tomography (DP-CBCT) vs pre-procedural second line imaging modality (SLIM [multidetector computed tomography and magnetic resonance imaging]) to detect and characterize hepatocellular carcinoma (HCC) in cirrhotic patients with indication for trans-arterial chemoembolization (TACE).
METHODS: This is a single centre, retrospective, and observational study. Exclusion criteria were not-assisted DP-CBCT TACE, and unavailable follow-up SLIM. We evaluated 280 consecutive patients (January/2015-Febraury/2019). Seventy-two patients were eligible. Three radiologists in consensus reviewed: pre-procedural SLIM, DP-CBCT, and SLIM at follow-up, with 4 months of interval between each reading. Hyper-vascular foci (HVF) were detected and characterized. Diameter was recorded. Radiological behaviour, according to LI-RADS criteria, of HFV throughout follow-up time was the reference standard. Diagnostic accuracy was calculated for pre-procedural SLIM and DP-CBCT and evaluated through receiver operating characteristic curve. HVF only visible on DP-CBCT (defined as occult) were analysed. Tumour diameters were compared.
RESULTS: Median time between pre-procedural SLIM and DP-CBCT and between DP-CBCT and definitive radiological diagnosis of HVF were 46.0 days (95%CI 36.5-55.0) and 30.5 days (95%CI 29.0-33.0), respectively. DP-CBCT had a better diagnostic performance than pre-examination SLIM (sensitivity 99%vs78%; specificity 89%vs85%; PPV 99%vs99%; NPV 92%vs30%; and accuracy 94%vs79%). DP-CBCT diagnosed 63 occult HVF. Occult HCC were 54/243 (22.2%). Six were occult angiomas. Three were false positive. Mean diameter was significantly higher in DP-CBCT vs pre-procedural SLIM (+7.5% [95%CI 3.7-11.3], p < 0.05).
CONCLUSIONS: DP-CBCT has a better diagnostic accuracy and NPV than pre-procedural SLIM in cirrhotic patients with indication for TACE.
引用
- Lucatelli P, De Rubeis G, Ginnani Corradini L, et al. Intra-procedural dual phase cone beam computed tomography has a better diagnostic accuracy over pre-procedural MRI and MDCT in detection and characterization of HCC in cirrhotic patients undergoing TACE procedure. Eur J Radiol. 2019. PMID: 31945673. doi:10.1016/j.ejrad.2019.108806
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。