文献速递外周血管神经头颈PETCTMR

18F-FDG摄取速度而非摄取水平与颈动脉斑块进展相关

18F-FDG uptake velocity but not uptake level is associated with progression of carotid plaque.
PubMed 文献 · Eur Radiol · 2020-01-03

研究纳入156例颈动脉斑块受试者,基线与12个月随访行颈动脉MRI、基线行PET-CT,评估18F-FDG摄取水平与摄取速度同斑块进展的关系。结果显示摄取水平与斑块进展无关,而摄取速度与斑块进展发生率独立相关,摄取速度与斑块增大的百分比无关。

要点

  • 18F-FDG摄取水平与颈动脉斑块进展无关联。
  • 18F-FDG摄取速度与斑块进展发生率独立相关(OR=0.682,p<0.05)。
  • 摄取速度与斑块增大的百分比无关联(趋势检验p=0.757)。

核心结论

  • 18F-FDG摄取速度与颈动脉斑块进展发生率独立相关,而摄取水平与斑块进展无关。
  • 18F-FDG摄取速度作为PET-CT的另一重要参数,值得在未来临床研究中进一步研究。

研究设计与样本

  • 研究纳入156例颈动脉斑块受试者,基线及12个月随访行颈动脉MRI,基线行PET-CT。
  • 斑块进展用斑块进展发生率和斑块增大百分比两个三维成像指标评估,18F-FDG摄取用摄取水平和摄取速度评估。
  • 采用趋势检验和多因素logistic回归分析斑块进展与18F-FDG摄取的关联。

诊断标准与关键数值

  • 12个月随访期间,156例中80例(51.3%)出现颈动脉斑块进展。
  • 不同摄取速度组间斑块进展发生率存在显著差异,从高到中到低呈显著下降趋势(趋势检验p=0.002)。
  • 校正协变量后,18F-FDG摄取速度对斑块进展发生率有足够预测能力(OR=0.682,p<0.05)。
  • 在斑块进展的受试者中,18F-FDG摄取速度与斑块增大百分比无关联(趋势检验p=0.757)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 18F-FDG摄取速度作为PET-CT的另一重要参数,值得在未来临床研究中进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: The objective of this study was to evaluate whether baseline 18F-fluorodeoxyglucose (FDG) uptake is associated with carotid plaque progression.

METHODS: A total of 156 subjects with carotid plaque were enrolled and underwent carotid magnetic resonance imaging (MRI) (at baseline and the 12-month follow-up) and positron emission tomography-computed tomography (PET-CT) (baseline). Carotid plaque progression was evaluated by two indices (the incidence of plaque progression and percentage of plaque increase) with three-dimensional (3D) imaging, while the 18F-FDG uptake was evaluated by the 18F-FDG uptake levels and 18F-FDG uptake velocity. The association between plaque progression and 18F-FDG uptake was investigated by the trend test and multivariate logistic regression analysis.

RESULTS: Of the 156 subjects, 80 (51.3%) showed carotid plaque progression during the 12-month follow-up. Firstly, no association was found between 18F-FDG uptake levels and plaque progression. Secondly, significant differences in the incidence of plaque progression were observed among the groups with different uptake velocities, showing a significant decreasing trend ranging from high to intermediate to low (p = 0.002, trend test). After adjusting for covariates, an adequate prediction of the 18F-FDG uptake velocity for the incidence of plaque progression was revealed (OR = 0.682, p < 0.05). In addition, no association was found between the 18F-FDG uptake velocity and the percentage of plaque increase in the subjects with plaque progression (p = 0.757, trend test).

CONCLUSIONS: Our findings suggest 18F-FDG uptake velocity is independently associated with the incidence of carotid plaque progression. Additionally, the 18F-FDG uptake velocity, as another important parameter of PET-CT, warrants further study in future clinical research.

KEY POINTS: • The18F-FDG uptake levels were not associated with the carotid plaque progression. • The18F-FDG uptake velocity could predict the incidence of carotid plaque progression. • The18F-FDG uptake velocity with related factors warrants more attention in future clinical research.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Li Y, Liang Y, Yang P, et al. 18F-FDG uptake velocity but not uptake level is associated with progression of carotid plaque. Eur Radiol. 2020. PMID: 31900697. doi:10.1007/s00330-019-06535-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。