本研究在猪骨关节炎模型中用全身光子计数探测器CT行双膝造影,多能量体模校准显示钆与羟基磷灰石定量准确,碘乙酸钠诱导膝出现1至3级软骨损伤而对照膝均为0级,分级分布差异有统计学意义(P=0.004),钆图显示诱导膝因关节积液对比剂水平较低,组织学证实软骨细胞丢失。

要点

  • 光子计数探测器CT膝关节造影可同时获取高分辨率形态图与多能量钆图,用于软骨损伤分级。
  • 碘乙酸钠诱导膝国际软骨修复学会评分1级表现为软骨不均质和髌股间隙增宽,3级表现为软骨侵蚀和骨对骨。
  • 诱导膝与对照膝分级分布差异有统计学意义(P=0.004),组织学与大体检查证实影像分级。

核心结论

  • 光子计数探测器CT膝关节造影可在大型骨关节炎动物模型中高分辨率、定量地评估软骨损伤。
  • 光子计数探测器CT同时具备高分辨率与多能量成像能力,可形态学评估软骨丢失并定量关节内对比剂水平作为关节疾病标志。
  • 碘乙酸钠诱导膝的软骨损伤经光子计数探测器CT图像分级,并由组织学和大体检查进一步证实。

研究设计与样本

  • 研究为猪骨关节炎模型研究,使用全身光子计数探测器CT。
  • 多能量体模含钆2、4、8、16 mg/mL和羟基磷灰石200、400 mg/cc,用于材料分解校准和定量准确性评估。
  • 8只尤卡坦迷你猪随机一侧膝关节注射1.2 mg碘乙酸钠诱导骨关节炎,对侧对照膝注射生理盐水。
  • 21天后双膝关节内注射钆特酸葡胺4 mL/膝,同时行光子计数探测器CT扫描(48×0.25 mm准直,80 kV,800 mAs)。
  • 多能量图像分别用锐利V71核和定量D50核重建,V71图像去噪后分级软骨损伤,D50图像行迭代材料分解生成钆图。

关键影像表现/征象

  • 体模材料分解图像可描绘和定量钆与羟基磷灰石,均方根误差分别为0.3 mg/mL和18.4 mg/cc。
  • 碘乙酸钠膝国际软骨修复学会评分从1级(软骨不均质,4膝)到3级(软骨丢失达100%,4膝)。
  • 1级特征为软骨不均质和髌股间隙增宽,3级特征为髌股间隙软骨侵蚀和骨对骨关节。
  • 所有对照膝评分为0级(正常软骨)。
  • 材料分解钆图显示碘乙酸钠膝关节间隙对比剂水平低于对侧对照膝,归因于关节积液。

诊断标准与关键数值

  • 采用改良国际软骨修复学会评分系统分级:0级为正常软骨,1级为软骨不均质,3级为软骨丢失达100%。
  • 碘乙酸钠膝与对照膝分级分布差异有统计学意义(P=0.004)。
  • 体模钆定量均方根误差0.3 mg/mL,羟基磷灰石定量均方根误差18.4 mg/cc。

临床应用与阅片要点

  • 阅片时可结合高分辨率形态图评估软骨不均质、间隙增宽、软骨侵蚀和骨对骨等征象进行分级。
  • 钆图可定量关节间隙对比剂水平,碘乙酸钠膝因关节积液对比剂水平低于对照膝。
  • 分级结果需结合大体检查和组织学所见,组织学显示碘乙酸钠膝软骨细胞丢失。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The aim of this study was to grade cartilage damage in a swine model of osteoarthritis using a whole-body photon-counting detector (PCD) CT.

MATERIALS AND METHODS: A multienergy phantom containing gadolinium (Gd) (2, 4, 8, and 16 mg/mL) and hydroxyapatite (200 and 400 mg/cc) was scanned using a PCD-CT system (48 × 0.25 mm collimation, 80 kV, 800 mAs, D50 reconstruction kernel) to serve as calibration for material decomposition and to assess quantification accuracy. Osteoarthritis was induced in Yucatan miniswine (n = 8) using 1.2 mg monoiodoacetate (MIA) injected into a randomized knee, whereas the contralateral control knee received saline. Twenty-one days later, a contrast bolus (gadoterate meglumine, 4 mL/knee) was intra-articularly administered into both knees. The knees were simultaneously scanned on the PCD-CT system (48 × 0.25 mm collimation, 80 kV, 800 mAs). Multienergy images were reconstructed with a sharp "V71" kernel and a quantitative "D50" kernel. Image denoising was applied to the V71 images before grading cartilage damage, and an iterative material decomposition technique was applied to D50 images to generate the Gd maps. Two radiologists blinded to the knee injection status graded the cartilage integrity based on a modified International Cartilage Repair Society scoring system. Histology was performed on excised cartilage using methylene blue/basic fuchsin. Statistical analysis of grade distribution was performed using an exact test of omnibus symmetry with P < 0.05 considered significant.

RESULTS: Material decomposed images from the multienergy phantom scan showed delineation and quantification of Gd and hydroxyapatite with a root-mean-squared error of 0.3 mg/mL and 18.4 mg/cc, respectively. In the animal cohort, the radiologists reported chondromalacia in the MIA knees with International Cartilage Repair Society scores ranging from grade 1 (cartilage heterogeneity, n = 4 knees) to grade 3 (up to 100% cartilage loss, n = 4 knees). Grade 1 was characterized by cartilage heterogeneity and increased joint space in the patellofemoral compartment, whereas grade 3 was characterized by cartilage erosion and bone-on-bone articulation in the patellofemoral compartment. All control knees were scored as grade 0 (normal cartilage). Significant difference (P = 0.004) was observed in the grade distribution between the MIA and control knees. Gross examination of the excised knees showed cartilage lesions in the grade 3 MIA knees. The Gd maps from material decomposition showed lower contrast levels in the joint space of the MIA knee compared with the contralateral control knee due to joint effusion. Histology revealed chondrocyte loss in the MIA knee cartilage confirming the chondrotoxic effects of MIA on cartilage matrix.

CONCLUSIONS: We demonstrated a high-resolution and quantitative PCD-CT arthrography technique for grading cartilage damage in a large animal model of osteoarthritis. Photon-counting detector CT offers simultaneous high-resolution and multienergy imaging capabilities that allowed morphological assessment of cartilage loss and quantification of contrast levels in the joint as a marker of joint disease. Cartilage damage in the MIA knees was graded using PCD-CT images, and the image-based findings were further confirmed using histology and gross examination of the excised knees.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Rajendran K, Murthy NS, Frick MA, et al. Quantitative Knee Arthrography in a Large Animal Model of Osteoarthritis Using Photon-Counting Detector CT. Invest Radiol. 2020. PMID: 31985604. doi:10.1097/RLI.0000000000000648

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。