手腕关节类风湿关节炎的超声分级研究
横断面研究纳入50例类风湿关节炎患者,采用肌骨超声对腕、掌指及近端指间关节行灰阶与能量多普勒半定量评分(0-3级),并与DAS28、实验室及Larsen评分相关。结果显示DAS28与能量多普勒信号、滑膜增厚、腱鞘炎、积液及Larsen评分显著相关(p<0.05),与超声或X线检出的骨侵蚀无显著相关(p>0.05)。作者认为肌骨超声在早期RA的滑膜炎、关节积液、腱鞘炎及骨侵蚀检出方面有重要作用。
要点
- 肌骨超声半定量评分(0-3级)可评估腕和手关节滑膜炎、积液、腱鞘炎及骨侵蚀。
- DAS28与能量多普勒信号、滑膜增厚、腱鞘炎、积液及Larsen评分显著相关(p<0.05)。
- DAS28与超声或X线检出的骨侵蚀无显著相关(p>0.05)。
核心结论
- 肌骨超声在检测早期类风湿关节炎的滑膜炎、关节积液、腱鞘炎和骨侵蚀方面有重要作用,且这些表现与临床和实验室参数相关。
研究设计与样本
- 横断面研究,在一家三级医院招募50例患者(49例女性、1例男性),平均年龄44.58±10.07岁,平均病程16.26±1.07年。
- 采用DAS28评估RA活动度,平均DAS28为5.19±0.95。
- 使用高频(18 MHZ)线阵探头对腕、掌指和近端指间关节行背侧纵切面肌骨超声检查。
- 评估100个腕关节(三个不同切面)、500个掌指关节和500个近端指间关节,采用灰阶超声和能量多普勒超声半定量量表,评分范围0-3分。
- 所有患者腕和手关节X线采用Larsen评分评估。
关键影像表现/征象
- 97.5%的关节Larsen评分为I级。
- 11.07%的关节可见骨侵蚀,9.2%的关节可见积液,23.8%的关节可见滑膜增厚,11.9%的关节可见能量多普勒信号,3.5%的关节伴有腱鞘炎。
诊断标准与关键数值
- 肌骨超声采用灰阶超声和能量多普勒超声半定量量表,评分范围0-3分。
- X线采用Larsen评分评估。
- DAS28与能量多普勒信号、滑膜增厚、腱鞘炎、积液及Larsen评分之间呈显著相关(p<0.05)。
- DAS28与肌骨超声和X线检出的骨侵蚀之间无显著相关(p>0.05)。
临床应用与阅片要点
- 肌骨超声半定量评分(0-3级)可用于腕和手关节滑膜炎、积液、腱鞘炎及骨侵蚀的评估。
- 能量多普勒信号、滑膜增厚、腱鞘炎、积液及Larsen评分与DAS28显著相关(p<0.05),阅片时可结合临床活动度指标。
- 肌骨超声和X线检出的骨侵蚀与DAS28无显著相关(p>0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To evaluate the role of musculoskeletal ultrasound (MSUS) in the grading of rheumatoid arthritis (RA) wrist and hand joints and correlate it with clinical, laboratory, and radiological data.
MATERIALS AND METHODS: A cross-sectional study recruited 50 patients in a tertiary care hospital. RA activity was assessed by DAS28. MSUS dorsal longitudinal scan was performed on the wrists, MCPs, and PIPS joints using high frequency (18 MHZ) linear transducer. 100 wrists in three different views, 500 MCPs, 500 PIPs were evaluated using the grayscale ultrasound and power Doppler ultrasound semiquantitative scale and scores ranging from 0-3. The results were correlated with clinical, laboratory and radiological data. All patients' wrist and hand joints X-rays were evaluated using the Larsen score.
RESULTS: The mean age of the patients (49 females and one male) was 44.58 ± 10.07 years, and their mean disease duration was 16.26 ± 1.07 years. The mean DAS28 was 5.19 ± 0.95. 97.5% of joints had grade I Larsen score, 11.07% of the joints had erosions, 9.2% of the joints had effusions, 23.8% of the joints had synovial thickening, 11.9% of the joints showed PD signals and 3.5% of the joints were accompanied with tenosynovitis. Significant relations (p < 0.05) found among DAS28 and (PD signals, synovial thickening, tenosynovitis, effusion, and Larsen score). A nonsignificant relation (p > 0.05) among DAS28 and erosions detected by MSUS and X-ray.
CONCLUSION: MSUS is powerful in the detection of early RA regarding synovitis, joint effusion, tenosynovitis, and bone erosions, which were correlated with clinical and laboratory parameters.
引用
- Seifeldein GS, Moussa DK, Galal MAA, et al. Grading of Ultrasonography in Rheumatoid Arthritis of Wrist and Hand Joints. Acad Radiol. 2020. PMID: 31980382. doi:10.1016/j.acra.2019.09.033
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。