指南与共识甲状腺与浅表头颈US

三种国际甲状腺结节超声分类指南的一致性及活检标准的诊断效能

Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria.
指南 / 共识 · Korean J Radiol · 2020-01-01

该研究基于两个多中心数据集的2586个≥1 cm甲状腺结节,比较韩国甲状腺协会/韩国甲状腺放射学会、美国甲状腺协会和美国放射学会三种指南的超声分类一致性及模拟活检标准的诊断效能。结果显示高或中 suspicious 结节一致性高(84.1-100%),低 suspicious 结节一致性较低(63.8-83.8%),原始活检标准的诊断效能差异主要受不同活检大小阈值影响,模拟相似活检大小标准后差异减小。

要点

  • 高或中 suspicious 结节三种指南分类一致性高(84.1-100%),低 suspicious 结节一致性较低(63.8-83.8%)。
  • 原始活检标准下三种指南敏感度差异0.7-19.8%,特异度差异0-40.9%,准确率差异0.1-30.5%。
  • 模拟相似活检大小标准后,敏感度差异降至0-5.9%,特异度差异降至0-10.9%,准确率差异降至0.1-8.2%。

核心结论

  • 三种指南对高或中 suspicious 结节分类一致性高,模拟相似活检大小标准后各指南活检标准的诊断效能大致相当,指南间诊断效能差异主要受不同活检大小阈值影响。

研究设计与样本

  • 从两个多中心研究数据集中收集2586个≥1 cm甲状腺结节,基于三种指南的超声恶性风险分类对结节进行分类并计算指南间一致性,同时评估四种不同模拟活检大小标准的诊断效能。

诊断标准与关键数值

  • 原始活检标准下,三种指南间敏感度差异0.7-19.8%,特异度差异0-40.9%,准确率差异0.1-30.5%;模拟相似活检大小标准下,敏感度差异0-5.9%,特异度差异0-10.9%,准确率差异0.1-8.2%;原始标准不必要活检率0-33.8%,模拟标准降至0-8.7%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the concordance of three international guidelines: the Korean Thyroid Association/Korean Society of Thyroid Radiology, American Thyroid Association, and American College of Radiology for thyroid nodules classified by ultrasonography (US) and the diagnostic performance of simulated size criteria for malignant biopsies.

MATERIALS AND METHODS: A total of 2586 thyroid nodules (≥ 1 cm) were collected from two multicenter study datasets. The classifications of the thyroid nodules were based on three different guidelines according to US categories for malignancy risk, and the concordance rate between the different guidelines was calculated for the classified nodules. In addition, the diagnostic performance of criteria related to four different simulated biopsy sizes was evaluated.

RESULTS: The concordance rate of nodules classified as high- or intermediate-suspicion was high (84.1-100%), but low-suspicion or mildly-suspicious nodules exhibited relatively low concordance (63.8-83.8%) between the three guidelines. The differences in sensitivity, specificity, and accuracy between the guidelines were 0.7-19.8%, 0-40.9%, and 0.1-30.5%, respectively, when the original biopsy criteria were applied. The differences decreased to 0-5.9%, 0-10.9%, and 0.1-8.2%, respectively, when simulated, similar biopsy size criteria were applied. The unnecessary biopsy rate calculated with the original criteria (0-33.8%), decreased with the simulated biopsy size criteria (0-8.7%).

CONCLUSION: We found a high concordance between the three guidelines for high- or intermediate-suspicion nodules, and the diagnostic performance of the biopsy criteria was approximately equivalent for each simulated size criterion. The difference in diagnostic performance between the three guidelines is mostly influenced by the various size thresholds for biopsies.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Yim Y, Na DG, Ha EJ, et al. Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria. Korean J Radiol. 2020. PMID: 31920034. doi:10.3348/kjr.2019.0215

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。