文献速递乳腺技术与安全US

超声弹性成像在乳腺癌腋窝淋巴结评估中的作用:系统评价与Meta分析

Role of sonoelastography in assessment of axillary lymph nodes in breast cancer: a systematic review and meta-analysis.
PubMed 文献 · Clin Radiol · 2019-12-28

该Meta分析纳入10项研究共1038枚腋窝淋巴结,评估剪切波弹性成像(SWE)与应变弹性成像(SE)鉴别良恶性腋窝淋巴结的效能。SWE最大硬度特异度0.94、AUC 0.94,平均硬度敏感度0.80;SE与SWE均有较高敏感度和特异度。作者认为SWE可作为前哨淋巴结活检的有效补充用于术前评估。

要点

  • SWE最大硬度鉴别良恶性腋窝淋巴结特异度0.94、AUC 0.94。
  • SWE平均硬度敏感度0.80(95%CI 0.61-0.91)。
  • 恶性腋窝淋巴结SWE硬度值显著高于良性淋巴结。

关键影像表现/征象

  • 恶性腋窝淋巴结的SWE硬度值显著高于良性淋巴结。

诊断标准与关键数值

  • SWE最大硬度:特异度0.94(95%CI 0.81-0.98)、PLR 12.1(95%CI 4-36.5)、NLR 0.29(95%CI 0.12-0.69)、AUC 0.94(95%CI 0.91-0.96)、DOR 42(95%CI 12-154)。
  • SWE平均硬度:敏感度0.80(95%CI 0.61-0.91)。
  • SE与SWE均具有较高的特异度和敏感度。

临床应用与阅片要点

  • 作者认为SWE是前哨淋巴结活检的有效补充,适用于Z0011时代后腋窝淋巴结的术前评估。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the effectiveness of shear-wave elastography (SWE) and strain elastography (SE) for axillary lymph nodes (ALNs).

MATERIALS AND METHODS: PubMed, Embase, and Cochrane Library databases were searched until September 2018. Weighted mean difference was calculated for continuous variables. The accuracy of sonoelastography was assessed by calculating pooled sensitivity, specificity, area under the curve (AUC), positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR). All data were analysed using Stata 12.0.

RESULTS: Ten studies with 1,038 ALNs were included in the meta-analysis. Five studies evaluated the use of SE, and the other five evaluated the SWE. The SWE stiffness values of malignant ALNs were significantly higher than those of benign nodes. Both SE and SWE have relatively high specificity and sensitivity. The max stiffness in SWE showed the highest specificity (0.94; 95% confidence interval [CI], 0.81-0.98), PLR (12.1; 95% CI, 4-36.5), NLR (0.29; 95% CI, 0.12-0.69), AUC (0.94; 95% CI, 0.91-0.96), and DOR (42; 95% CI, 12-154); in contrast, the mean stiffness showed the highest sensitivity (0.80; 95% CI, 0.61-0.91).

CONCLUSION: Sonoelastography demonstrated high sensitivity and specificity for differentiating between malignant and benign ALNs. The max and mean stiffness on SWE appeared to exhibit the highest accuracy. Thus, SWE is an effective accompaniment to sentinel node biopsy, and is appropriate for preoperative assessment of ALNs in the post-Z0011 era.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Wang RY, Zhang YW, Gao ZM, et al. Role of sonoelastography in assessment of axillary lymph nodes in breast cancer: a systematic review and meta-analysis. Clin Radiol. 2019. PMID: 31892406. doi:10.1016/j.crad.2019.11.016