文献速递乳腺技术与安全US

乳腺淋巴瘤的超声诊断及与乳腺浸润性导管癌的鉴别

Ultrasound Diagnosis of Breast Lymphoma and the Identification of Breast Infiltrating Ductal Carcinoma.
PubMed 文献 · J Ultrasound Med · 2019-12-31

研究对比32例乳腺淋巴瘤(BL)与30例乳腺浸润性导管癌(BIDC)的B超和彩色多普勒血流成像特征。BL平均最大径54.93±43.74 cm,BIDC为23.90±6.79 cm(P<.05)。结节型BL边界清晰、密度高,弥漫型BL无清晰边界、无钙化、无聚集特征及密度;BL血供较BIDC更丰富。

要点

  • BL病灶平均最大径大于BIDC(54.93±43.74 cm vs 23.90±6.79 cm,P<.05)。
  • 结节型BL边界清晰、密度高,弥漫型BL无清晰边界、钙化、聚集及密度。
  • BL病灶血供较BIDC更丰富(P<.05)。

关键影像表现/征象

  • 结节型BL与BIDC在边界清晰(60.00% vs 20.00%)、钙化(20.00% vs 53.33%)、聚集特征(0.00% vs 53.33%)和密度(73.33% vs 10.00%)上差异有统计学意义(P<.05)。
  • 弥漫型BL与BIDC在钙化(6.67% vs 53.33%)、聚集特征(6.67% vs 53.33%)和密度(40.00% vs 10.00%)上差异有统计学意义(P<.05)。
  • BL亚组间边界清晰比例差异有统计学意义(结节型60% vs 弥漫型13.33%,P<.05)。

诊断标准与关键数值

  • BL平均最大径54.93±43.74 cm,BIDC平均最大径23.90±6.79 cm(P<.05)。
  • 结节型BL边界清晰60.00%、钙化20.00%、聚集特征0.00%、密度73.33%;BIDC分别为20.00%、53.33%、53.33%、10.00%(P<.05)。
  • 弥漫型BL钙化6.67%、聚集特征6.67%、密度40.00%;BIDC分别为53.33%、53.33%、10.00%(P<.05)。

临床应用与阅片要点

  • 外上象限单发较大病灶需考虑BL可能,结节型BL多边界清晰且密度高。
  • 弥漫型BL缺乏边界清晰、钙化、聚集特征和密度,血供较BIDC更丰富,可作为鉴别参考。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: By analyzing the B-mode ultrasound and color Doppler flow imaging characteristics of breast lymphoma (BL) and breast infiltrating ductal carcinoma (BIDC), we expected to discriminate these diseases.

METHODS: Thirty-two patients with BL and 30 with BIDC confirmed pathologically were selected. The BL group was divided into nodular and diffuse groups. We analyzed and compared the general and imaging characteristics of the BL subgroups and the BIDC group.

RESULTS: The mean maximum diameter of BL was 54.93 ± 43.74 cm, and that of BIDC was 23.90 ± 6.79 cm (P < .05). The differences between the nodular BL and BIDC groups in a circumscribed margin (60.00% versus 20.00%), calcification (20.00% versus 53.33%), aggregation characteristics (0.00% versus 53.33%), and density (73.33% versus 10.00%) were statistically significant (P < .05). The differences between the diffuse BL and BIDC groups in calcification (6.67% versus 53.33%), aggregation characteristics (6.67% versus 53.33%) and density (40.00% versus 10.00%) were statistically significant (P < .05). The difference in a circumscribed margin (60% versus 13.33%) between the BL subgroups was statistically significant (P < .05). The blood flow signal in BL lesions was richer than that in BIDC lesions (P < .05).

CONCLUSIONS: Extrasuperior-quadrant single lesions in the BL group were larger than those in the BIDC group. The edges of the lesions in the nodular BL group were circumscribed and dense. Lesions in the diffuse BL group did not have a circumscribed margin, calcification, aggregation characteristics, or density. The blood flow signal in BL lesions was richer than that in BIDC lesions.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Chen Y, Zhou JH, Fan HX, et al. Ultrasound Diagnosis of Breast Lymphoma and the Identification of Breast Infiltrating Ductal Carcinoma. J Ultrasound Med. 2019. PMID: 31891216. doi:10.1002/jum.15209

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。