文献速递妇产影像腹部MR

磁共振表现用于鉴别卵巢蜕膜化子宫内膜异位囊肿与浆黏液性交界性肿瘤

MR findings for differentiating decidualized endometriomas from seromucinous borderline tumors of the ovary.
PubMed 文献 · Abdom Radiol (NY) · 2020-01-01

本研究回顾性评估8例蜕膜化子宫内膜异位囊肿与14例浆黏液性交界性肿瘤的MRI表现,比较壁结节的定量与定性特征。结果显示壁结节数目、T1WI信号强度比、分叶状边缘、带蒂构型及T2低信号核心在两组间差异显著,有助于鉴别。

要点

  • 壁结节数目多、T1WI信号强度比高、结节矮小提示蜕膜化子宫内膜异位囊肿。
  • 分叶状边缘、带蒂构型、T2低信号核心更常见于浆黏液性交界性肿瘤。
  • T2WI信号强度比、DWI信号强度比及ADC值在两组间无显著差异。

关键影像表现/征象

  • 壁结节数目在蜕膜化子宫内膜异位囊肿为11.0 ± 8.4个,多于浆黏液性交界性肿瘤的4.3 ± 4.1个(p < 0.05)。
  • 壁结节高度在蜕膜化子宫内膜异位囊肿为4.5 ± 1.4 mm,低于浆黏液性交界性肿瘤的21.9 ± 11.4 mm(p < 0.01)。
  • 分叶状边缘在浆黏液性交界性肿瘤中占71%,在蜕膜化子宫内膜异位囊肿中占0%(p < 0.01)。
  • 带蒂构型在浆黏液性交界性肿瘤中占86%,在蜕膜化子宫内膜异位囊肿中占0%(p < 0.01)。
  • T2低信号核心在浆黏液性交界性肿瘤中占43%,在蜕膜化子宫内膜异位囊肿中占0%(p < 0.05)。

诊断标准与关键数值

  • 壁结节T1WI信号强度比在蜕膜化子宫内膜异位囊肿为2.36 ± 0.56,高于浆黏液性交界性肿瘤的1.49 ± 0.27(p < 0.01)。
  • 壁结节T2WI信号强度比、DWI信号强度比及ADC值在蜕膜化子宫内膜异位囊肿与浆黏液性交界性肿瘤间无显著差异。

临床应用与阅片要点

  • 阅片时注意评估子宫内膜异位囊肿内壁结节的数目、高度及T1WI信号强度比,以帮助鉴别蜕膜化子宫内膜异位囊肿与浆黏液性交界性肿瘤。
  • 分叶状边缘、带蒂构型及T2低信号核心的出现更支持浆黏液性交界性肿瘤。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Decidualized endometriomas (DEs) and seromucinous borderline tumors (SMBTs) exhibit similar MR findings including markedly hyperintense mural nodules within endometriotic cysts on T2-weighted images. The present study aimed to assess the efficacy of MR imaging for differentiating between DEs and SMBTs of the ovary.

MATERIALS AND METHODS: MR images of 8 DEs and 14 SMBTs were retrospectively assessed and compared according to pathologies.

RESULTS: With regard to quantitative assessments of mural nodules, the number and signal intensity ratios (SIRs) on T1-weighted images were significantly greater in DEs than in SMBTs (11.0 ± 8.4 vs. 4.3 ± 4.1, p < 0.05 and 2.36 ± 0.56 vs. 1.49 ± 0.27, p < 0.01, respectively), whereas the height was significantly lower in DEs than in SMBTs (4.5 ± 1.4 mm vs. 21.9 ± 11.4 mm, p < 0.01). However, there were no significant differences between DEs and SMBTs in the SIRs on T2-weighted images, SIRs on diffusion-weighted images, and apparent diffusion coefficient values. With regard to qualitative assessments of mural nodules, the lobulated margin, pedunculated configuration, and T2 hypointense core were significantly more frequent in SMBTs than in DEs (71% vs. 0%, p < 0.01; 86% vs. 0%, p < 0.01; and 43% vs. 0%, p < 0.05, respectively).

CONCLUSION: The number, height, SIRs on T1-weighted images, lobulated margin, pedunculated configuration, and T2 hypointense core of mural nodules within endometriotic cysts were useful MR findings for differentiating DEs from SMBTs.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Ando T, Kato H, Kawaguchi M, et al. MR findings for differentiating decidualized endometriomas from seromucinous borderline tumors of the ovary. Abdom Radiol (NY). 2020. PMID: 31960119. doi:10.1007/s00261-020-02412-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。