同相位梯度回波图像信号丢失鉴别小肾细胞癌与乏脂性血管平滑肌脂肪瘤的诊断准确性
该回顾性研究评估同相位梯度回波图像上信号丢失对肾细胞癌与乏脂性血管平滑肌脂肪瘤的鉴别诊断准确性。主观评估信号丢失诊断特异度为100%、敏感度为38.5%,定量信号强度指数两组间差异无统计学意义(p=0.26)。作者认为该征象可用于提高MRI术前诊断准确性。
要点
- 同相位梯度回波图像上主观评估信号丢失对鉴别肾细胞癌与乏脂性血管平滑肌脂肪瘤特异度达100%。
- 该征象敏感度较低(38.5%),阴性结果不能排除肾细胞癌。
- 定量信号强度指数在两组间差异无统计学意义(p=0.26),诊断价值有限。
核心结论
- 同相位图像上主观评估的信号丢失对鉴别肾细胞癌与乏脂性血管平滑肌脂肪瘤高度特异,但敏感度低;作者认为该发现可用于提高MRI对肾脏肿块的术前诊断准确性。
研究设计与样本
- 回顾性研究,检索机构数据库纳入经组织学证实的最大径小于5.0 cm的小肾细胞癌及无可见宏观脂肪的血管平滑肌脂肪瘤(乏脂性血管平滑肌脂肪瘤)。
- 两名有经验的放射科医生对MRI进行定性评估,判断同相位梯度回波图像上的信号丢失灶;第三名放射科医生在同一病灶的同相位与反相位图像上勾画感兴趣区以计算信号丢失比值。
- 对两种技术分别计算诊断准确性参数,定性分析的阅片者间一致性采用κ检验评估。
关键影像表现/征象
- 15例(38.4%)肾细胞癌在同相位图像上出现信号丢失。
诊断标准与关键数值
- 主观评估同相位图像信号丢失鉴别肾细胞癌与乏脂性血管平滑肌脂肪瘤:敏感度38.5%(95%CI 23.4-55.4),特异度100%(71.1-100),阳性预测值100%(73.4-100),阴性预测值31.4%(26.3-37.0),总体准确率52%(37.4-66.3)。
- 定量分析信号强度指数(SII=[(SIIP-SIOP)/SIOP]×100):肾细胞癌为-0.132±0.05,乏脂性血管平滑肌脂肪瘤为-0.031±0.02,p=0.26;AUC为0.414±-0.09(0.237-0.592)。
- 以19%信号丢失为阈值时,敏感度16%,特异度100%。
- 主观分析的κ值为0.63。
临床应用与阅片要点
- 同相位梯度回波图像上主观评估的信号丢失可作为鉴别肾细胞癌与乏脂性血管平滑肌脂肪瘤的高特异征象,但敏感度低,阴性时不能排除肾细胞癌。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess the diagnostic accuracy of signal loss on in-phase (IP) gradient-echo (GRE) images for differentiation between renal cell carcinomas (RCCs) and lipid-poor angiomyolipomas (lpAMLs).
METHODS: We retrospectively searched our institutional database for histologically proven small RCCs (<5.0 cm) and AMLs without visible macroscopic fat (lpAMLs). Two experienced radiologists assessed MRIs qualitatively, to depict signal loss foci on IP GRE images. A third radiologist drew regions of interest (ROIs) on the same lesions, on IP and out-of-phase (OP) images to calculate the ratio of signal loss. Diagnostic accuracy parameters were calculated for both techniques and the inter-reader agreement for the qualitative analysis was evaluated using the κ test.
RESULTS: 15 (38.4%) RCCs lost their signal on IP images, with a sensitivity of 38.5% (95% CI = 23.4-55.4), a specificity of 100% (71.1-100), a positive predictive value (PPV) of 100% (73.4-100), a negative predictive value (NPV) of 31.4% (26.3-37.0), and an overall accuracy of 52% (37.4-66.3%). In terms of the quantitative analysis, the signal intensity index (SII= [(SIIP - SIOP) / SIOP] x 100) for RCCs was -0.132 ± 0.05, while for AMLs it was -0.031 ± 0.02, p = 0.26. The AUC was 0.414 ± -0.09 (0.237-0.592). Using 19% of signal loss as the threshold, sensitivity was 16% and specificity was 100%. The κappa value for subjective analysis was 0.63.
CONCLUSION: Signal loss in "IP" images, assessed subjectively, was highly specific for distinction between RCCs and lpAMLs, although with low sensitivity. The findings can be used to improve the preoperative diagnostic accuracy of MRI for renal masses.
ADVANCES IN KNOWLEDGE: Signal loss on "IP" GRE images is a reliable sign for differentiation between RCC and lpAMLs.
引用
- Lima FVA, Elias J, Chahud F, et al. Diagnostic accuracy of signal loss in in-phase gradient-echo images for differentiation between small renal cell carcinoma and lipid-poor angiomyolipomas. Br J Radiol. 2020. PMID: 31971819. doi:10.1259/bjr.20190975
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。