3 T 肾脏同时多层扩散加权成像
这项回顾性分析纳入 40 例前瞻性计划队列中接受肾脏磁共振成像的患者,在 3 T 设备上比较呼吸触发同时多层加速扩散加权成像(SMS-RT-DWI)与标准自由呼吸平面回波扩散加权成像(s-DWI)的图像质量和伪影。结果显示 SMS-RT-DWI 的整体图像质量、肾边缘与肾实质锐利度、皮髓质分化及病灶可辨识度均优于 s-DWI,序列相关伪影更少,采集时间缩短 30%,平均信噪比更高而信噪比异质性更低,两者平均表观扩散系数值在肾脏内均匀性相当。
要点
- SMS-RT-DWI 整体图像质量、肾边缘及肾实质锐利度均优于 s-DWI,序列相关伪影更少(P < 0.01)。
- SMS-RT-DWI 病灶可辨识度显著改善(P < 0.01),两位阅片者对 40/40 例均更偏好 SMS-RT-DWI。
- SMS-RT-DWI 采集时间较 s-DWI 缩短 30%,平均信噪比更高、信噪比异质性更低。
关键影像表现/征象
- SMS-RT-DWI 的整体图像质量、肾边缘和肾实质锐利度被阅片者评为优于 s-DWI,且序列相关伪影更少(P < 0.01)。
- SMS-RT-DWI 的病灶可辨识度显著改善(P < 0.01)。
- 两位阅片者在所有病例中均更偏好 SMS-RT-DWI(40/40)。
- SMS-RT-DWI 在 b = 800 s/mm 时的平均信噪比异质性在统计学上显著低于 s-DWI,而平均信噪比显著高于 s-DWI。
- 两种序列所得平均表观扩散系数值在肾脏内均匀性相当。
诊断标准与关键数值
- 图像质量采用 5 分 Likert 量表评估整体偏好、图像质量、肾边缘与肾实质锐利度、皮髓质分化和序列相关伪影。
- 信噪比从信噪比图中测量,并比较两种序列所得平均表观扩散系数值。
临床应用与阅片要点
- SMS-RT-DWI 可在 3 T 肾脏扩散加权成像中提供优于 s-DWI 的图像质量和病灶可辨识度,且采集时间缩短 30%。
- SMS-RT-DWI 的序列相关伪影更少,两位阅片者在全部 40 例中均更偏好该序列。
- 两种序列的平均表观扩散系数值在肾脏内均匀性相当。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: The aim of this study was to compare respiratory-triggered diffusion-weighted imaging with simultaneous-multislice acceleration (SMS-RT-DWI) to a standard free-breathing echoplanar DWI (s-DWI) for 3 T renal imaging with respect to image quality and artifacts.
MATERIALS AND METHODS: A total of 40 patients who had undergone renal magnetic resonance imaging were included in this retrospective analysis of a prospectively planned cohort study. All examinations were performed on a 3 T whole-body magnetic resonance system. Both s-DWI and SMS-RT-DWI were obtained and images were independently reviewed by 2 radiologists on a 5-point Likert scale with respect to overall preference and image quality, renal edge and parenchymal sharpness, cortico-medullary differentiation, and sequence-related artifacts. Furthermore, discernibility of renal lesions was assessed. The signal-to-noise ratio (SNR) was measured from SNR maps. The derived mean apparent diffusion coefficients were also compared. Qualitative parameters were assessed with the Wilcoxon rank-sum test, and quantitative parameters, with the Student t test.
RESULTS: Overall image quality, renal edge, and parenchymal sharpness of SMS-RT-DWI were rated as superior to s-DWI by the readers, with fewer sequence-related artifacts (P < 0.01 for all). Lesion discernibility was significantly improved for SMS-RT-DWI (P < 0.01). Both readers preferred SMS-RT-DWI to s-DWI in all cases (40/40). The acquisition time for SMS-RT-DWI was 30% shorter than for s-DWI. Mean SNR heterogeneity of SMS-RT-DWI at b = 800 s/mm was statistically significantly lower than s-DWI, whereas mean SNR was significantly higher for SMS-RT-DWI. Mean apparent diffusion coefficient values from both sequences were comparably homogeneous throughout the kidneys.
CONCLUSION: Simultaneous multislice DWI of the kidney at 3 T with respiratory triggering yields substantially improved image quality and lesion discernibility compared with standard single-shot echoplanar DWI with a 30% reduction in scan acquisition time.
引用
- Tavakoli A, Krammer J, Attenberger UI, et al. Simultaneous Multislice Diffusion-Weighted Imaging of the Kidneys at 3 T. Invest Radiol. 2020. PMID: 31917764. doi:10.1097/RLI.0000000000000637
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。