声孔化胰腺癌细胞的长期命运与模型分子载入程度不相关
研究以FITC-右旋糖酐为模型分子混合2% v/v SonoVue微泡,在0.25、0.6、1.2 MPa峰值负压、1 MHz频率、300 μs脉冲下辐照胰腺癌细胞,用流式细胞术按荧光强度分3个亚组分析长期命运。结果显示0.6 MPa递送效率与细胞活力最高,各亚组凋亡与坏死比例随培养时间增加但组间无显著差异,声孔化细胞长期命运涉及线粒体信号蛋白。
要点
- 0.6 MPa下递送效率与细胞活力最高,被选为后续实验参数。
- 按荧光强度分3个亚组,亚组2和3的FITC-右旋糖酐荧光强度分别约为亚组1的5.62倍和19.53倍。
- 培养6 h和24 h后,3个亚组间凋亡(p > 0.05)与坏死(p > 0.05)比例均无显著差异。
关键影像表现/征象
- 0.25 MPa下发生稳定空化,微泡呈超谐波发射。
- 0.6 MPa和1.2 MPa下观察到明显宽带信号,提示发生惯性空化。
诊断标准与关键数值
- 按流式细胞术荧光强度分布将声孔化细胞分为3个亚组,亚组2和3的FITC-右旋糖酐荧光强度分别约为亚组1的5.62倍和19.53倍。
- 0.6 MPa下细胞分析显示最大递送效率和细胞活力,被选为后续实验参数。
- 培养6 h和24 h后,3个亚组间凋亡(p > 0.05)与坏死(p > 0.05)比例均无显著差异。
临床应用与阅片要点
- 作者认为这些结果有助于理解空化增强通透性的作用,并为声学空化设计提供关键指导。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Studies have determined that ultrasound-activated microbubbles can increase the membrane permeability of tumor cells by triggering membrane perforation (sonoporation) to improve drug loading. However, because of the distinct cavitation events adjacent to each cell, the degree of drug loading appeared to be heterogeneous. The relationship between the long-term fate trend and the degree of drug loading remains unclear. To investigate the time-lapse viability of diversity loading cells, fluorescein isothiocyanate-dextran (FITC-dextrans) was used as a molecular model mixed with 2% v/v SonoVue microbubbles (Bracco, Milan, Italy) and exposed to various peak negative pressures (0.25 MPa, 0.6 MPa, 1.2 MPa), 1 MHz frequency and 300 μs pulse duration. To select a suitable parameter, the cavitation activity was measured, and the cell analysis was performed by flow cytometry under these acoustic pressures. The sonoporated cells were then categorized into 3 sub-groups by flow cytometry according to the various fluorescence intensity distributions to analyze their long-term fate. We observed that the stable cavitation occurred at 0.25 MPa and microbubbles underwent ultra-harmonic emission, and obvious broadband signals were observed at 0.6 MPa and 1.2 MPa, suggesting the occurs of inertial cavitation. The cell analysis further showed the maximum delivery efficiency and cell viability at 0.6 MPa, and it was selected for the following experiment. The categorization displayed that the fluorescence intensity of FITC-dextrans in sub-groups 2 and 3 were approximate 5.62-fold and 19.53-fold higher than that in sub-group 1, respectively. After separation of these sub-groups, the apoptosis and necrosis ratios in all 3 sub-groups of sonoporated cells gradually increased with increasing culture time and displayed no significant difference in either the apoptosis (p > 0.05) or necrosis (p > 0.05) ratio after 6 h and 24 h of culture, respectively. Further analysis using Western blot verified that the long-term fate of sonoporated cells involves the mitochondrial signaling proteins. These results provide better insight into the role of cavitation-enhanced permeability and a critical guide for acoustic cavitation designs.
引用
- Lin L, Cheng M, Wu R, et al. The Long-Term Fate of the Sonoporated Pancreatic Cancer Cells is Uncorrelated With the Degree of Model Molecular Loading. Ultrasound Med Biol. 2020. PMID: 31932158. doi:10.1016/j.ultrasmedbio.2019.10.026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。