文献速递腹部技术与安全CT

大体重患者快速kVp切换双能CT门静脉期腹部扫描:图像质量考量

Rapid kVp-switching DECT portal venous phase abdominal CT scans in patients with large body habitus: image quality considerations.
PubMed 文献 · Abdom Radiol (NY) · 2020-01-01

回顾性纳入2014年9月至2018年3月接受快速kVp切换双能CT门静脉期腹部扫描的体重≥90 kg连续患者,评估65 keV单能图、碘密度图和水密度图的图像质量与伪影。65 keV单能图诊断可接受率97.8%,碘密度图和水密度图分别有20.4%和26.9%出现显著图像质量下降;碘密度图诊断可接受的体重阈值为110 kg、BMI阈值为33.5 kg/m²。

要点

  • 体重≥90 kg患者行快速kVp切换双能CT门静脉期腹部扫描时,65 keV单能图诊断可接受率97.8%。
  • 碘密度图20.4%、水密度图26.9%出现显著图像质量下降(诊断可接受性评分<3)。
  • 碘密度图诊断可接受的体重阈值为110 kg、BMI阈值为33.5 kg/m²,超过此阈值图像质量下降。

关键影像表现/征象

  • 65 keV单能图诊断可接受性评分≥3者占97.8%(91/93)。
  • 碘密度图诊断可接受性评分<3者占20.4%(19/93),水密度图诊断可接受性评分<3者占26.9%(25/92)。
  • 碘密度图和水密度图分别有31%(29/93)和32.3%(30/93)见临床显著伪影(伪影评分≥3/4)。

诊断标准与关键数值

  • 碘密度图诊断可接受的体重阈值为110 kg,BMI阈值为33.5 kg/m²,由AUC和约登指数计算得出。
  • 诊断可接受性评分≥3定义为诊断质量可接受,伪影评分≥3/4定义为临床显著伪影。

临床应用与阅片要点

  • 对体重≥90 kg患者可选用快速kVp切换双能CT门静脉期扫描,65 keV单能图诊断可接受性高。
  • 阅片时注意碘密度图和水密度图在体重>110 kg或BMI>33.5 kg/m²患者中伪影增多、图像质量下降。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the diagnostic image quality and material decomposition characteristics of portal venous phase abdominal CT scans performed on rapid kVp-switching DECT (rsDECT) in patients with large body habitus.

METHODS: We retrospectively included consecutive patients with large body habitus (≥ 90 kg) undergoing portal venous phase abdominal CT scans on rsDECT scanners between Sep 2014 and March 2018. Qualitative and quantitative assessment of the DECT data sets [65 keV monoenergetic, material density iodine (MD-I) and material density water (MD-W) images] was performed for determination of image quality (IQ) and image noise. Correlation of qualitative assessment scores with weight, BMI and patients' diameter were calculated using Pearson correlation test. Optimal thresholds were calculated using AUC and Youden index to define most appropriate size cut off, below which the IQ of material density images is largely acceptable.

RESULTS: The 65 keV monoenergetic images were of diagnostic quality (diagnostic acceptability, DA ≥ 3) in 97.8% of patients (n = 91/93). However, there was significant IQ degradation of MD-I images in 20.4% (n = 19/93, DA < 3) of patients. Similarly, there was significant degradation (DA < 3) of MD-W images in 26.9% (25/92). Clinically significant artifacts (PA ≥ 3/4) were seen in 31% (n = 29/93) and 32.3% (30/93) of MD-I and MD-W images respectively. Optimal threshold for diagnostic acceptability of MD-I images were 110 kg for weight and 33.5 kg/m2 for BMI.

CONCLUSION: Rapid kVp-switching DECT provides diagnostically acceptable monoenergetic images for patients with large body habitus (≥ 90 kg). There is degradation of IQ in the material density specific images particularly in patients weighing > 110 kg and with BMI > 33.5 kg/m2, due to higher number of artifacts.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Baliyan V, Kordbacheh H, Pourvaziri A, et al. Rapid kVp-switching DECT portal venous phase abdominal CT scans in patients with large body habitus: image quality considerations. Abdom Radiol (NY). 2020. PMID: 31996988. doi:10.1007/s00261-020-02416-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。