前瞻性比较缩减视野与全视野扩散加权成像在胰岛素瘤评估中的图像质量与病灶检出
该前瞻性研究纳入67例疑似胰岛素瘤患者,比较缩减视野(rFOV)与全视野(fFOV)扩散加权成像(DWI)的图像质量和病灶检出性能。结果显示rFOV DWI的主观图像质量评分、信噪比和对比噪声比均显著高于fFOV DWI,对小于1.5 cm病灶的检出率及总体检出敏感度也显著提高,且两者ADC值一致。作者建议rFOV DWI可作为fFOV DWI的可靠辅助替代方案用于临床检出胰腺胰岛素瘤。
要点
- rFOV DWI的图像质量评分、SNR和CNR均显著优于fFOV DWI(均p<0.05)。
- 对小于1.5 cm的病灶,rFOV DWI检出率90.7% vs fFOV DWI 75.9%(p=0.039)。
- rFOV DWI检出敏感度0.924 vs fFOV DWI 0.773(p=0.013)。
关键影像表现/征象
- 50例患者为肿瘤阳性,共65个肿瘤,大小1.31±0.77 cm(范围0.6-5.8 cm)。
- rFOV DWI的图像质量评分3.64±0.487 vs fFOV DWI 3.310±0.577(p<0.05)。
- rFOV DWI的SNR 22.520±8.690 vs fFOV DWI 10.284±3.321(p<0.05)。
- rFOV DWI的CNR 3.454±2.642 vs fFOV DWI 1.327±2.801(p<0.05)。
诊断标准与关键数值
- 对小于1.5 cm的病灶(n=55),rFOV DWI检出率90.7% vs fFOV DWI 75.9%(p=0.039)。
- rFOV DWI检出敏感度0.924 vs fFOV DWI 0.773(p=0.013)。
- 两种DWI序列测得的胰岛素瘤和正常胰腺实质ADC值一致。
临床应用与阅片要点
- 作者建议rFOV DWI可作为fFOV DWI的可靠辅助替代方案用于临床检出胰腺胰岛素瘤。
- 对于小于1.5 cm的胰岛素瘤病灶,rFOV DWI的检出率更高,阅片时可优先关注该序列。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To prospectively compare the image quality (IQ) and lesion detection performance of reduced field-of-view (rFOV) and full FOV (fFOV) diffusion-weighted imaging (DWI) sequences in detecting insulinomas.
MATERIALS AND METHODS: From October 2017 to September 2018, 67 patients with suspected insulinomas were prospectively enrolled and underwent imaging with both types of DWI sequences. The slice thickness (4 mm) and slice gaps (1 mm) were the same for the two DWI sequences, and the TR/TE was 2235/56 ms for the rFOV sequence and 1892/63 ms for the fFOV sequence. Three radiologists independently assessed the imaging quality (IQ) subjectively with a 5-point scale and objectively with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurements. The IQ scores, CNR, SNR, lesion detection rates, and ADC values were compared. Receiver operating characteristic curves were generated, and the area under the curve (AUC) was used to compare the diagnostic performance.
RESULTS: Fifty patients were tumor positive, with 65 tumors (size: 1.31 ± 0.77 cm, range: 0.6-5.8 cm). The IQ score, SNR, and CNR were significantly higher for rFOV DWI than for fFOV DWI (IQ: 3.64 ± 0.487 vs 3.310 ± 0.577, SNR: 22.520 ± 8.690 vs 10.284 ± 3.321, CNR: 3.454 ± 2.642 vs 1.327 ± 2.801, and all p < 0.05). For lesions less than 1.5 cm (n = 55), the lesion detection rates of the rFOV were statistically improved compared to those of the fFOV (90.7% vs. 75.9%, p = 0.039). The sensitivity of lesion detection was significantly improved with the rFOV-DWI sequences compared to that with the fFOV-DWI sequences (0.924 vs. 0.773, p = 0.013). The ADC values of the two DWI sequences were consistent for insulinomas and normal parenchyma.
CONCLUSION: Considering the improvements in overall IQ and lesion detection and the consistency of ADC measurements, we suggest that rFOV DWI is a reliable auxiliary alternative to fFOV DWI for clinical practice in the detection of pancreatic insulinomas.
引用
- He M, Xu J, Sun Z, et al. Prospective Comparison of Reduced Field-of-View (rFOV) and Full FOV (fFOV) Diffusion-Weighted Imaging (DWI) in the Assessment of Insulinoma: Image Quality and Lesion Detection. Acad Radiol. 2020. PMID: 31954606. doi:10.1016/j.acra.2019.11.019
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。