双时间点18F-FDG PET/CT显像在结直肠癌肝转移诊断中的附加价值
本研究纳入108例结直肠癌肝转移患者,术前均行双时间点18F-FDG PET/CT扫描,所有肝脏病灶经组织病理学诊断。按病灶分析,延迟扫描总敏感度显著高于早期扫描(83.49% vs 76.61%,P<0.001),对≤10 mm病灶延迟扫描敏感度亦显著更高(47.17% vs 26.42%,P<0.001)。结论认为双时间点显像可能检出更多结直肠癌肝转移病灶,尤其是小病灶(<10 mm)。
要点
- 按病灶分析,延迟扫描敏感度显著高于早期扫描(83.49% vs 76.61%,P<0.001)。
- 对≤10 mm的结直肠癌肝转移灶,延迟扫描敏感度显著高于早期扫描(47.17% vs 26.42%,P<0.001)。
- 延迟扫描SUVmax、肿瘤/正常本底比值均显著高于早期扫描,正常肝本底SUVmean显著降低。
核心结论
- 双时间点18F-FDG PET/CT显像较单时间点显像可能检出更多结直肠癌肝转移病灶,尤其是<10 mm的小病灶。
研究设计与样本
- 本研究为术前双时间点18F-FDG PET/CT显像诊断研究,纳入108例结直肠癌肝转移患者。
- 所有肝脏病灶均以组织病理学诊断为标准。
- 分别计算早期扫描与延迟扫描对结直肠癌肝转移的诊断敏感度,采用McNemar检验比较早期与延迟扫描间敏感度和特异度的差异。
关键影像表现/征象
- 延迟扫描检出182个肝脏转移灶,其SUVmax显著高于早期扫描(12.13 ± 7.13 vs 9.16 ± 4.74,P<0.001)。
- 正常肝脏延迟扫描SUVmean显著低于早期扫描(1.91 ± 0.29 vs 2.33 ± 0.31,P<0.001)。
- 延迟扫描肿瘤/正常本底比值显著高于早期扫描(6.59 ± 4.43 vs 4.02 ± 2.23,P<0.001)。
诊断标准与关键数值
- 按患者分析,早期扫描与延迟扫描敏感度分别为92.93%与96.97%,差异无统计学意义(P=0.125)。
- 按患者分析,早期与延迟扫描特异度均为77.78%。
- 按病灶分析,延迟扫描总敏感度显著高于早期扫描(83.49% vs 76.61%,P<0.001)。
- 按病灶分析,早期与延迟扫描特异度均为69.23%。
- 对≤10 mm的结直肠癌肝转移灶,延迟扫描敏感度显著高于早期扫描(47.17% vs 26.42%,P<0.001);对>10 mm的病灶,早期与延迟扫描敏感度分别为92.73%与95.15%,差异无统计学意义(P=0.125)。
临床应用与阅片要点
- 延迟扫描可提高结直肠癌肝转移灶的检出敏感度,尤其对≤10 mm的小病灶。
- 延迟扫描SUVmax及肿瘤/正常本底比值均高于早期扫描,正常肝本底SUVmean低于早期扫描。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the added value of dual-time-point 18F-FDG PET/CT imaging in the diagnosis of colorectal cancer liver metastases (CRLM).
METHODS: One hundred and eight patients with CRLM preoperatively underwent a dual-time-point 18F-FDG PET/CT scan. All hepatic lesions were diagnosed by histopathology. The diagnostic sensitivity of 18F-FDG PET/CT for CRLM was calculated on early scan and delayed scan, respectively. The McNemar test was used to test the differences of the sensitivity and the specificity between early scan and delayed scan.
RESULTS: On a per-patient basis, no significant difference in sensitivity was found between early scan and delayed scan (92.93% vs. 96.97%, P = 0.125). The per-patient specificity of early and delayed scans was 77.78%. On a per-lesion basis, overall sensitivity of delayed scan was significantly higher than that of early scan (83.49% vs. 76.61%, P < 0.001). The per-lesion specificity of early and delayed scans was 69.23%. For the lesion size of CRLM ≤ 10 mm, delayed imaging had significantly higher sensitivity than early imaging (47.17% vs. 26.42%, P < 0.001). However, for CRLM > 10 mm, there was no significant difference in sensitivity between early and delayed scans (92.73% vs. 95.15%, P = 0.125). Of the detected 182 liver metastatic lesions on delayed scan, the SUVmax on delayed scan was significantly higher than that on early scan (12.13 ± 7.13 vs. 9.16 ± 4.74, P < 0.001). The SUVmean of the normal liver on delayed scan was significantly lower than that on early scan (1.91 ± 0.29 vs. 2.33 ± 0.31, P < 0.001). The tumor to normal background ratio on delayed scan was significantly higher than that on early scan (6.59 ± 4.43 vs. 4.02 ± 2.23, P < 0.001).
CONCLUSION: The dual-time-point 18F-FDG PET/CT imaging might detect more CRLM lesions compared with single-time-point imaging, especially for small (< 10 mm) lesions.
引用
- Mao W, Zhou J, Qiu L, et al. The added value of dual-time-point 18F-FDG PET/CT imaging in the diagnosis of colorectal cancer liver metastases. Abdom Radiol (NY). 2020. PMID: 31927618. doi:10.1007/s00261-019-02396-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。