基于卷积神经网络的肝脏MR图像两步法自动质量评估
本研究纳入150例T2加权肝脏MR检查,由两名放射科医生将每层图像标注为不可诊断或可诊断并手动分割肝脏区域,训练两个卷积神经网络分别完成肝脏分割和图像块质量分类,以肝脏区域中不可诊断图像块百分比判定整幅图像质量;模型准确率88.3%、敏感度86.0%、特异度89.4%、AUC 0.911(95%CI 0.882-0.939,P<0.05),混淆矩阵与放射科医生判断一致性良好。
要点
- 两步法先分割肝脏区域再对肝内图像块分类,以不可诊断图像块占全部肝脏图像块的比例判定整幅图像质量。
- 以不可诊断为阳性时,模型准确率88.3%、敏感度86.0%、特异度89.4%、AUC 0.911(95%CI 0.882-0.939)。
- 混淆矩阵显示模型与两名放射科医生的判断一致性良好。
临床应用与阅片要点
- 阅片时可参考该两步法思路:先定位肝脏区域,再逐块判断图像块是否满足诊断要求。
- 整幅图像质量以肝内不可诊断图像块所占比例判定,而非仅凭单层或局部表现。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To propose an automatic approach based on a convolutional neural network (CNN) to evaluate the quality of T2-weighted liver magnetic resonance (MR) images as nondiagnostic (ND) or diagnostic (D).
MATERIALS AND METHODS: We included 150 T2-weighted liver MR imaging examinations in this retrospective study. Each slice of liver image was annotated with a label D or ND by two radiologists with seven and six years of experience, respectively. Additionally, the radiologists segmented the liver region manually as the ground truth for liver segmentation. A CNN was trained to segment the liver region and another CNN was used to classify the qualities of patches extracted from the liver region. The quality of an image was obtained from the percentage of nondiagnostic patches in all liver patches in the image. Treating nondiagnostic as positive, the accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), area under the receiver operating characteristic curve (AUC), and confusion matrix were used to evaluate our model. A Mann-Whitney U test was performed with the statistical significance set at 0.05.
RESULTS: Our model achieved good performance with an accuracy of 88.3 %, sensitivity of 86.0 %, specificity of 89.4 %, PPV of 78.6 %, NPV of 93.4 %, and AUC of 0.911 (95 % confidence interval: 0.882-0.939, p < 0.05). The confusion matrix of our model indicated good concordance with that of the radiologists.
CONCLUSIONS: The proposed two-step patch-based model achieved excellent performance when assessing the quality of liver MR images.
引用
- Wang Y, Song Y, Wang F, et al. A two-step automated quality assessment for liver MR images based on convolutional neural network. Eur J Radiol. 2020. PMID: 31951895. doi:10.1016/j.ejrad.2020.108822
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。